FDNY WRITTEN EXAM QUESTIONS & ANSWERS The amount of refrigerant that flows through the orifices of an economizer is determined by the - Answer -Difference between the high side and low side pressure If a compressor discharge temperature has dropped significantly and the suction line pressure is high, this may be caused by - Answer -An expansion valve that is open too wide

Show more Read less
Institution
FDNY
Course
FDNY










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FDNY
Course
FDNY

Document information

Uploaded on
November 23, 2025
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

FDNY WRITTEN EXAM QUESTIONS & ANSWERS

A more efficient centrifugal compressor operation results from - Answer -Lowering the
condensing pressure

The heat removed from the refrigerant in a condenser is - Answer -Sensible and latent
heat

According to the New York City fire code, refrigerant containers must - Answer -Be
approved by the US Department of Transportation

The cylinder unloader works by - Answer -Keeping the suction valve opened while the
compressor is in the return stroke

In most semi-hermetic compressors, the suction vapor is used to - Answer -Cool the
motor

The amount of refrigerant that flows through the orifices of an economizer is determined
by the - Answer -Difference between the high side and low side pressure

The installation of an inline refrigerant cleaning system is advisable to - Answer -
Remove impurities from the system

The type of refrigerant system least likely to leak refrigerant into the building space is -
Answer -The indirect system

The compression ratio for a reciprocating compressor with a suction pressure of 65
PSIG and a discharge pressure of 120 PSIG is closest to - Answer -1.69

A superheated vapor is - Answer -Dry vapor above the saturation temperature

A condenser water pump cavitating is most likely caused by - Answer -A faulty cooling
tower water level controller

A centrifugal water pump is known as a lift pump when - Answer -The water supply to
the pump suction inlet is below the pump level

A TXV is used to maintain constant - Answer -Evaporator superheat

A chilled water supply of 55°F for human comfort is - Answer -Too high for human
comfort purpose

The packing gland of a centrifugal pump serves to - Answer -Keep air out of the pumps
when the impeller housing is under negative pressure

,Capacity control of a reciprocating hermetic compressor is typically achieved through -
Answer -Operation of the hot gas bypass valve

The most important reason to sub-cool the refrigerant in the condenser is to ensure that
- Answer -A pure liquid refrigerant will enter the metering device

If a compressor discharge temperature has dropped significantly and the suction line
pressure is high, this may be caused by - Answer -An expansion valve that is open too
wide

A low side float valve is used to maintain - Answer -The level of the refrigerant in the
evaporator

The ASHRAE refrigerant safety classification indicating no flammability and lower
toxicity is - Answer -A1

When an expansion valve is operating properly, the end of the evaporator will contain -
Answer -Only superheated vapor

Information not contained in a Material Safety Data Sheet (MSDS) includes - Answer -
Cost of the material

In a steam turbine, the Kingsbury thrust bearing functions to - Answer -Maintain axial
positioning of the rotor shaft

A centrifugal water pump is considered fully primed when - Answer -The pump is full of
liquid

To avoid collapsing tubing when making bends, a refrigerant engineer should use -
Answer -Lever type tubing bender

A reciprocating compressor making a clicking sound during operation, if not caused by
worn parts, is probably due to - Answer -Slugging of the liquid refrigerant

For a refrigerant to become superheated, it must be heated in a section of the low side
refrigerant line - Answer -Where no liquid refrigerant is present

After all liquid refrigerant has been recovered, the system - Answer -Should not be
opened until all vapor has been recovered

The removal rate of refrigerant using a portable compressor recovery unit gradually
slows down because - Answer -The vapor density is decreasing

If the water level in all cooling tower cells is very low, the immediate action should be to
- Answer -Add additional makeup water to the cooling tower

, The height of the water column, in feet, with a pressure gauge reading 140 PSIG is
closest to - Answer -323 feet

The device that protects a steam turbine from excessive speed is the - Answer -
Governor assembly

If a refrigeration compressor fails to turn on, after verifying the electrical circuit, the next
item to check would be the - Answer -Temperature and pressure controls

Of the refrigerants in commercial and industrial use, the one with the highest latent heat
and refrigerant effect is - Answer -Ammonia

The ASHRAE refrigerant safety group classification system is based on - Answer -
Flammability and toxicity

An example of an in-line refrigerant cleaning system for a centrifugal compressor
containing R123 refrigerant is - Answer -Refrigerant recycling

Information about the physical and chemical properties of a hazardous material can be
found in the - Answer -Material Safety Data Sheet (MSDS)

The function of the turbine auxiliary oil pump is to - Answer -Establish oil pressure
during turbine start-up

The rupture disc for a low-pressure centrifugal refrigeration machine is normally located
on the - Answer -Compressor suction

Ribbed metal piping is used for electrical wires connected to the refrigeration system
primarily because - Answer -It allows for flexibility and accounts for vibrations

If some of the cylinder unloaders on a multi-cylinder reciprocating compressor fail to
operate, one likely outcome is that - Answer -The chilled water temperature will
increase

If the suction gauge of a condenser water pump reads 55 PSI, draining the 75 feet long,
12-inch diameter pipe would yield approximately - Answer -440 gallons of water

A leak in the evaporator shell of a system using R123 refrigerant might result in -
Answer -A higher than normal high side pressure

The function of capacitors used on refrigeration motors is to - Answer -Store electrical
charges during starting and running the motor

A centrifugal refrigerant machine is best characterized as a - Answer -High volume, low
pressure machine

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
1978
Member since
3 year
Number of followers
1445
Documents
45436
Last sold
7 hours ago

3.8

341 reviews

5
167
4
63
3
44
2
16
1
51

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions