Dialysis Final Exam || 100% Error-free Answers.
When washing hands with soap and water, how long must you wash your hands? correct
answers 40-60 seconds

When cleaning hands with hand sanitizer, how long must you rub your hands? correct
answers 20-30 seconds

What is the number one cause of chronic renal failure? correct answers diabetes

TRUE or FALSE: When going from a dirty area to retrieve supplies in a clean area, staff are
required to complete hand hygiene. correct answers True

TRUE or FALSE: Hazardous Material Identification System HMIS labels are required on all
hazardous materials, including individual bicarbonate containers. correct answers True

The first bleach solution used to clean a large blood spill area (greater than 10ml/s) is? correct
answers 1:10

The main route of transmission of Hepatitis B in hemodialysis facilities is by exposure to
_____ and ______. correct answers blood and bodily fluids

When caring for a patient who is Hepatitis B positive, after disconnecting the bloodlines, the
technician MUST perform which 3 actions? correct answers remove gloves, sanitize hands,
put on fresh gloves

According to CDC, patients who are Hepatitis B surface antigen (HBsAg) positive should be
dialyzed in a ______ area of the dialysis center, on ______ machine. correct answers
separate, designated

What must the dialysis technician do prior to leaving the patient at the dialysis station to get
clean supplies? Remove ______. _______/_______ hands and retrieve items. correct answers
gloves, wash/sanitize hands

The dialysis technician has performed a rinseback on a patient and failed to gather all the
supplies needed to disconnect the patient. What 2 things must the technician do prior to
getting clean supplies? correct answers remove gloves, wash/sanitize hands

You must wear a full-face shield, or mask with goggles, when in an area with a risk of _____
______. correct answers blood splatter

Use of a diasafe filter allows for the production of ______ ______. correct answers ultrapure
dialysate

_________ is the ability of a substance to conduct an electrical charge. correct answers
conductivity

What is used to rinse and prime the tubing of the extracorporeal circuit to remove sterilant
and air? correct answers normal saline

, Why is air removed from the extracorporeal circuit before initiating treatment? correct
answers it may cause clotting when trapped in the dialyzer

What is the most likely cause of contamination of the extracorporeal circuit? correct answers
bloodlines in the prime bucket with open end caps

A low-level arterial drip chamber can result in _____ entering the system causing an air
embolism or clotting. correct answers air

When blood escapes from the dialyzer blood compartment into the dialysate fluid
compartment, what is this known as? correct answers blood leak

The final dialysate must have a pH between: ___ and ___ correct answers 6.9 and 7.6

How often should staff clean the dialysis machine with acid? correct answers daily

When should alarm and Pressure Holding Tests (PHT) should be performed on dialysis
machines? correct answers before each treatment

What is removed by normal saline during the priming process? correct answers air in dialyzer

Before the start of treatment, check that the machine's conductivity alarm parameters are set
at? correct answers +/- 0.5m mS of the TCD

You should disinfect the dialysis machine with heat after doing what? correct answers after
disinfecting with acid

You should test the dialysate for these four things before starting treatment: correct answers
bacteria, conductivity, chlorine, & pH

The wall clock indicates the patient has had 3 hours of treatment and the machine indicates
only 2 1/2 hours treatment. What happened? correct answers The machine was in bypass for
30 minutes

Urine flows through the ____ ____ from the kidneys, to the ______, to the _____, to the
_____. correct answers urinary tract, ureters, bladder, urethra

What is considered the access of choice because they have the lowest complication rate?
correct answers fistula

A patient with severe hypertension is to start hemodialysis. The patient does not have
diabetes or cardiac problems. What type of access is preferable? correct answers AV fistula

The goals of dialysis are to remove ____, remove excess ____ and regulate ____. correct
answers waste, water, electrolytes

Name the 3 places in the body where most of the water is located. correct answers
intracellular, interstitial, extracellular

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton NURSING, ECONOMICS, MATHEMATICS, BIOLOGY, AND HISTORY MATERIALS BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS, AND STUDY GUIDE MATERIALS WITH GUARANTEED A+ I am a dedicated medical practitioner with diverse knowledge in matters
View profile
Follow You need to be logged in order to follow users or courses
Sold
735
Member since
3 year
Number of followers
437
Documents
34580
Last sold
2 days ago
Reign Supreme Scholarly || Enlightened.

Here we offer revised study materials to elevate your educational outcomes. We have verified learning materials (Research, Exams Questions and answers, Assignments, notes etc) for different courses guaranteed to boost your academic results. We are dedicated to offering you the best services and you are encouraged to inquire further assistance from our end if need be. Having a wide knowledge in Nursing, trust us to take care of your Academic materials and your remaining duty will just be to Excel. Remember to give us a review, it is key for us to understand our clients satisfaction. We highly appreciate clients who always come back for more of the study content we offer, you are extremely valued. All the best.

Read more Read less
3.7

110 reviews

5
46
4
20
3
22
2
8
1
14

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions