100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

IEC YEAR 2 FINAL EXAM QUESTIONS AND ANSWERS 2025

Rating
-
Sold
3
Pages
14
Grade
A+
Uploaded on
21-11-2025
Written in
2025/2026

IEC YEAR 2 FINAL EXAM QUESTIONS AND ANSWERS 2025

Institution
IEC YEAR 2
Course
IEC YEAR 2









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
IEC YEAR 2
Course
IEC YEAR 2

Document information

Uploaded on
November 21, 2025
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

IEC YEAR 2 FINAL EXAM QUESTIONS AND ANSWERS 2025




Refer to the information shown in Figure 234.151. When the tap for Motor 3 terminates in a safety
switch, the maximum permitted size for DETD fuses in this switch would be _____ A. - (ANSWER)15



Refer to the information shown in Figure 234.151. When the tap for Motor 1 terminates in a breaker
enclosure, the maximum permitted size for an ITCB in this enclosure would be ____ A. - (ANSWER)70



Refer to the information shown in Figure 234.151. When th etap for Motor 3 terminates in a breaker
enclosure, the maximum permitted size for an ITCB in this enclose would be ____ A. - (ANSWER)none of
these



Voltage Drop Scenario #3

The distance between the panel and a load is 150 feet. The circuit to the load consists of two 12 AWG
solid copper coated conductors that are connected to a 1-pole breaker in a 277/480-volt, 3Ø, 4-wire
panel and the neutral bar. The load draws 9.8 amps.



Refer to Voltage Drop Scenario #3. If the voltage drop is to be limited to 2.2%, this is ___ volts. -
(ANSWER)6.09



Refer to Figure 221.404. The voltage applied to Heating Element B is ___ volts. - (ANSWER)138.6



Refer to the nameplate and heater selection table, shown above in Figure 230.122. For a correctly sized
starter, the heater catalog number for the heaters is ___. This motor is supplied power from a 120/240-
volt, 3-phase, 4-wire panelboard. - (ANSWER)B32



Refer to the nameplate shown in Figure 230.122. The branch circuit for the motor is supplied from a
240/120-volt, 3Ø, 4-wire panelboard. What is the minimum size (3 wire + ground) SO cord that could be
used as a flexible connection for the motor? - (ANSWER)8



Refer to the nameplate shown in Figure 230.122. This motor should draw ___ amps at rated voltage
when connected to Circuit 4-6-8 that is fed from a 3-pole breaker in a 120/240-volt, 3Ø, 4-wire
panelboard. - (ANSWER)18.6

, IEC YEAR 2 FINAL EXAM QUESTIONS AND ANSWERS 2025




Two lighting circuits are supplied from a multiwire branch circuit that originates in a 120/240 volt, 1Ø, 3-
wire panelboard. Two, 20 Amp, 1-pole breakers are installed in spaces 22 & 24 for the multiwire circuit.
Circuit 22 has 2600 watts of lights connected to it, and Circuit 24 has 2100 watts of lights connected to
it. Which of the following should happen to Circuit 22? - (ANSWER)An overload will occur and the
breaker will trip.



Refer to Figure 221.402. If Ammeter 2 indicates 38.5 amps, the generator is delivering ___ kW of power.
- (ANSWER)16.0



The service disconnecting means for a 3-phase service is permitted to consist of ___. - (ANSWER)any of
the above



Nontime-delay fuses are to be installed in a safety switch adjacent to a motor. See Figure 230.225. Fuses
with a rating not exceeding ___ A are permitted. - (ANSWER)100



The classification of a location, where ignitable concentrations of flammable liquid-produced vapors or
combustible liquid-produced vapors exist under normal operating conditions, is ___. - (ANSWER)Class I,
Division 1



If a 4-wire, wye-connected supply system has a line-to-line voltage of 13.5 kV, what is the line-to-neutral
voltage? - (ANSWER)7,800



Refer to the motor nameplate shown in Figure 230.108. A NEMA starter will be used for this motor. The
fewest number of heaters that can be installed in the starter per the NEC ® is ___. The motor circuit is
supplied from a 2-pole breaker in a 120/240-volt, 3Ø, 4-W panel. - (ANSWER)1



A transformer has a primary rated voltage of 120 and a secondary rated voltage of 16. If the current in
the circuit conductors connected to the primary is 1.1 amps, the load that is connected to the secondary
must be drawing ___ amps. - (ANSWER)8.25



A set of wires (black, red, blue and green) are installed between a 3-pole safety switch and a 3Ø motor.
The direction of rotation of the motor can be changed by swapping the ___ wire connections on the
load side of the switch. - (ANSWER)black and blue

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Belaire Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
2749
Member since
1 year
Number of followers
0
Documents
1355
Last sold
1 day ago

5.0

498 reviews

5
486
4
11
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions