PLUMBING EXAM WITH CORRECT ANSWERS-UPDATED (2025-
2026)


A journeyman plumber and an apprentice, who are employed by a master plumber, are
installing the DWV-system and water distribution system in a 2-½ story single family
dwelling. QUESTION: What answer below shall be considered most correct to complete
the following "Plumbing code knowledge" related statement: A trap that serves a single
shower stall that is equipped with a hand shower, a rain head, and a standard shower head
shall be no less than ________ in minimum diameter



A) 1-½" B) 2" C) 2-½" D) 3"

Correct answer: 2 inches



A journeyman plumber and apprentice are installing 3-inch oor drains in an open-parking-
garage that is subject to freezing temperatures. QUESTION: What answer below shall be
considered most correct to complete the following "Plumbing code knowledge" related
statement: The installation of traps at the oor drain locations which are found susceptible
to freezing temperatures may be __________.



A)Increased to 4-inch B) Eliminated C) Wrapped with freeze protection cable D) Insulated

Correct answer: eliminated



A journeyman plumber and apprentice are installing lab sinks with faucets that are
connected to an acid waste system for-(special hazardous waste) in a medical lab. What
answer below shall be considered most correct to complete the following "Plumbing code
knowledge" related statement: Vacuum breakers shall be installed with the critical level at
least _____-inches above the ood level rim of the xture they serve and on the discharge
side of the last control valve to the xture.



A) 12 B) 6 C) 18 D) 3

,Correct answer: 6 inches



What answer below shall be considered most correct to complete the following "Plumbing
code knowledge" related statement: No plumbing permit shall be issued for cross
connection installations that require ______________ until the application for a permit is
accompanied by a letter of approval from the Massachusetts Department of Environmental
Protection or its designee.



A) RPBP B) A "critical level" height C) Atmospheric vacuum breakers D) Water recycling
systems

Correct answer: reduced pressure backow preventer (RPBP)



: What answer below shall be considered most correct to complete the following "Plumbing
code knowledge" related statement: The waste discharge from safe waste pans serving
water heaters or hot water storage tanks where there is _______ below and shall be piped
indirectly to a properly trapped and vented xture.



A) People B) Occupancy C) Floors D) Plumbing connections

Correct answer: occupancy



GIVEN: A journeyman plumber and an apprentice, (who are employed by a master
plumber), are installing the sanitary DWV and water distribution system in a ve-story
residential condominium complex. QUESTION: What answer below shall be considered
most correct to complete the following "Plumbing code knowledge" related statement:
CPVC-(Chlorinated Polyvinyl Chloride) pipe and ttings may be used provided that none of
this material is located within ____-inches of any connection to a hot water tank as dened
in MGL. c. 142, § 17



A) 12 B) 18 C) 20 D) 24 E) 30

Correct answer: 24 inches

,: A journeyman plumber and apprentice are roughing-in multiple xtures in a new tness
center. The facility will include a juice bar, temporary daycare room, men's and women's
toilet facilities and men's and women's locker rooms. QUESTION: What answer below shall
be considered most correct to complete the following "Plumbing code knowledge" related
statement: A ________-vent is a branch vent that serves two or more oor-outlet xtures
that are battery wasted. The vent extends from the top of the horizontal soil and/or waste
branch in front of the last xture waste and connects to a vent stack or stack vent that is
adjacent to the down-stream end of the horizontal branch.



A) Side B) Loop C) Relief D) Circuit

Correct answer: loop



MATCH:

Elevated pressure

Flow designation

Ten P.S.I.G. or less

Less than 2-P.S.I

A) 3 P.S.I.G. or ten times

B) Inlet pressure

C) E.H.D.

D) Prof. Engineer

Correct answer: elevated pressure- d

ow designation-c

Ten P.S.I.G. or less-a

Less than 2-P.S.I-b

, N: A journeyman plumber is installing category-I gas appliances and equipment in the
basement of a building. A 120,000 BTU/hr. boiler and 40,000 BTU/hr. water heater are being
installed. QUESTION: What answer below shall be considered most correct to complete
the following "Gas code knowledge" related statement: The boiler requires a minimum of
_____-cu. ft. of air to support proper combustion



A) 2,400 cu. ft. B) 120 sq. in. C) 3,200 sq. ft. D) 800 cu. ft.

Correct answer: 2,400 cu. ft. 120,000/50



) QUESTION: What answer below shall be considered most correct to complete the
following "Gas code knowledge" related statement: The code would require the gas vent
penetrating the roof in-[FIGURE-TP-B-Q1-1A: GAS VENT SIZING] as identied at point-[A] to
be not less than ______ above any portion of a building within 10-feet horizontally.



A) 24" B) 3-feet C) 30-inches D) Forty-two-inches

Correct answer: 24



In Massachusetts copper tubing and ttings may be used for natural gas piping



A) Provided that the tubing is type-k with ared tting connections. B) When approved by
the authority having jurisdiction.

C) At interior locations only and not concealed.

D) If the gas contains no more than .03 grains of hydrogen sulde per 100 cu. ft. of gas.

Correct answer: If the gas contains no more than .03 grains of hydrogen sulde per 100 cu.
ft. of gas



: A journeyman plumber and apprentice, who are employed by a master plumber, are
installing a natural gas red category-1 boiler and water heater to an interior, clay tile lined,
masonry chimney. When measured in compliance with the code the chimney "height" is
48-feet. QUESTION: What answer below shall be considered most correct to complete the
$12.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
ProfZ

Get to know the seller

Seller avatar
ProfZ Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
4 months
Number of followers
0
Documents
227
Last sold
2 months ago
ProfZ

Hi there I'm ProfZ, let's ace those exams together! :)

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions