TFM02 - TEXAS FIRE EXTINGUISHER LICENSING TEST TYPE B QUESTIONS AND ANSWERS VERIFIED 100% CORRECT 5 ft above the ground - ANSWER -extinguishers weighing 40 lbs or less must be installed so top of canister is no more than _____ K - ANSWER -class ___ extinguishers are for fires involving cooking media 75 ft - ANSWER -OSHA specified max travel distance for Class A is ______ C - ANSWER -proper UL rating to use on electrically energized equipped Class K - ANSWER -work on the principle of saponification Obstacle Type Fires - ANSWER -involve flammable liquid on a horizontal surface w/ the presence of a solid object creating a barrier 4 inches - ANSWER -extinguishers must be installed at least _____ from the ground Obstacle Type Fires - ANSWER -may take place in flammable liquid storage caninets, dip tank process areas, etc. Must Be Weighed - ANSWER -To make sure the pressure gauges of CO2 extinguisher are showing adequate pressure, what must you do? 5 yrs - ANSWER -Wetting agent portable extinguishers must be hydrostatic tested every _____ After recharge - ANSWER -leak tests on stored pressure extinguishers must be performed cannot - ANSWER -how do u convert fire extinguishers from 1 type to another? any remaining dry chemical in a discharged extinguisher - ANSWER -may be reused only if checked for proper type, contamination, and condition. closed recovery system needs to be used! New extinguishers needing charge in the field - ANSWER -do not need to have any verification of service collar installed you cannot - ANSWER -how do u have an extinguisher converted to use a different type of extinguishing agent annually - ANSWER -the gauge used to set the regulated source of pressure needs to be calibrated annually - ANSWER -pump tank calcium chloride based antifreeze typesof extinguishers need to be recharged 75 ft. - ANSWER -OSHA specified max distance to extinguisher for Class D weighing - ANSWER -when you recharge, the amount of recharge agent to use should be verified by Aqueous Film Forming Foam (AFFF) - ANSWER -these types of extinguishers must have hydrostatic testing every 5 yrs annually - ANSWER -The wetting agent in stored pressure wetting agent extinguishers must be replaced 3 yrs - ANSWER -The premixed agent in liquid charge-type AFFF and FFFP extinguishers must be replaced every cylinder-operated extinguishers - ANSWER -do not need to have any verification of service collar installed False - ANSWER -you are free to mixmultipurpose dry chemicals w/ alkaline based dry chemicals must be avoided - ANSWER -subsurface injection of wet chemical extinguishing agents into hot cooking media False - ANSWER -You should NEVER place extinguishers in cabinets or wall recesses. 5 yrs - ANSWER -how often must CO2 portable extinguishers go through hydrostatic testing? Special Hazards - ANSWER -Pressurized gas fires and pressurized flammable liquids. Type B, Special Hazards - ANSWER -Type ___ extinguishers w/ agents other than dry chemicals are not very effective on ______ Do not attempt - ANSWER -How do you filed adjust regulators that are utilized on wheeled fire extinguishers? False - ANSWER -You do not need to keep permanent file record for each extinguisher unless it has been in use for over 1 1/2 yrs Permanant File Record - ANSWER -needed for each extinguisher including: maintenance date, name, and agency performing maintenance. Dry Nitrogen - ANSWER -used as an expellant gas for stored-pressure fire extinguishers is not recommended - ANSWER -connecting the fire extinguisher to the high pressure source for direct charging False - ANSWER -the problem with halon agent is that it leaves a lot of residue after use. may be weakened when under fire exposure - ANSWER -the structural integrity of aluminum shells False - ANSWER -The system used to rate effectiveness of extinguishers on Class B fires is applicable to pressurized flammable liquid greater - ANSWER -Potassium base bicarbonate agents offer _____ capabilities when compared to sodium bicarbonate agents Corrosive - ANSWER -there are several types of dry chemical agents. the problem w/ potassium chloride based agent is that it is:

Show more Read less
Institution
TFM02 - TEXAS FIRE EXTINGUISHER LICENSING
Course
TFM02 - TEXAS FIRE EXTINGUISHER LICENSING









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
TFM02 - TEXAS FIRE EXTINGUISHER LICENSING
Course
TFM02 - TEXAS FIRE EXTINGUISHER LICENSING

Document information

Uploaded on
November 18, 2025
Number of pages
8
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

TFM02 - TEXAS FIRE EXTINGUISHER LICENSING
TEST TYPE B QUESTIONS AND ANSWERS
VERIFIED 100% CORRECT
5 ft above the ground - ANSWER -extinguishers weighing 40 lbs or less must be
installed so top of canister is no more than _____

K - ANSWER -class ___ extinguishers are for fires involving cooking media

75 ft - ANSWER -OSHA specified max travel distance for Class A is ______

C - ANSWER -proper UL rating to use on electrically energized equipped

Class K - ANSWER -work on the principle of saponification

Obstacle Type Fires - ANSWER -involve flammable liquid on a horizontal
surface w/ the presence of a solid object creating a barrier

4 inches - ANSWER -extinguishers must be installed at least _____ from the
ground

Obstacle Type Fires - ANSWER -may take place in flammable liquid storage
caninets, dip tank process areas, etc.

Must Be Weighed - ANSWER -To make sure the pressure gauges of CO2
extinguisher are showing adequate pressure, what must you do?

5 yrs - ANSWER -Wetting agent portable extinguishers must be hydrostatic
tested every _____

After recharge - ANSWER -leak tests on stored pressure extinguishers must be
performed

cannot - ANSWER -how do u convert fire extinguishers from 1 type to another?

any remaining dry chemical in a discharged extinguisher - ANSWER -may be
reused only if checked for proper type, contamination, and condition. closed
recovery system needs to be used!

, New extinguishers needing charge in the field - ANSWER -do not need to have
any verification of service collar installed

you cannot - ANSWER -how do u have an extinguisher converted to use a
different type of extinguishing agent

annually - ANSWER -the gauge used to set the regulated source of pressure needs
to be calibrated

annually - ANSWER -pump tank calcium chloride based antifreeze typesof
extinguishers need to be recharged

75 ft. - ANSWER -OSHA specified max distance to extinguisher for Class D

weighing - ANSWER -when you recharge, the amount of recharge agent to use
should be verified by

Aqueous Film Forming Foam (AFFF) - ANSWER -these types of extinguishers
must have hydrostatic testing every 5 yrs

annually - ANSWER -The wetting agent in stored pressure wetting agent
extinguishers must be replaced

3 yrs - ANSWER -The premixed agent in liquid charge-type AFFF and FFFP
extinguishers must be replaced every

cylinder-operated extinguishers - ANSWER -do not need to have any verification
of service collar installed

False - ANSWER -you are free to mixmultipurpose dry chemicals w/ alkaline
based dry chemicals

must be avoided - ANSWER -subsurface injection of wet chemical extinguishing
agents into hot cooking media

False - ANSWER -You should NEVER place extinguishers in cabinets or wall
recesses.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheExamMaestro Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
121
Member since
1 year
Number of followers
5
Documents
3167
Last sold
1 week ago
Exam Vault

Exam Vault is your trusted destination for high-quality exam materials and study resources. We provide a wide rage of tests and prep guides to help you succeed, whether you're preparing for academic exams, certifications, or professional assessments

3.8

13 reviews

5
7
4
2
3
1
2
0
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions