Verified 100% Correct
Maintenance & Repairing Compressor- General Requirements - ANSWER --
always follow guidelines outlined by manufacturer.
Repair:
-always turned off
-electrical supply shutdown
-air drained
-made by qualified technician
Repairs by CF - ANSWER --must know how to correct cooling system;
-may replace belts
-change air filter
-change lubrication oil
Leaks - ANSWER -CF must look & listen for leaks.
More prominent in colder months when sealing materials shrink.
Most leakage occurs at tubing and fittings at air reciever tank.
Heat & Compressor - ANSWER --never place combustible materials nearby;
-do not use near devices that produce heat;
solar heat is not known to cause overheating
CF Responsibility - ANSWER --visually inspect
-remain in area for a few minutes after compressor started
-do not operate at speeds above recommended ranged
Injury from Compressor - ANSWER --Dust or debris blow off clothing can be
driven under skin causing DEATH
-Eardrum ruptures at 40 PSI
-Air entering mouth can destroy lungs and internal organs
-Eyesight (always wear googles)
, Hydrostatic testing - ANSWER -Fire Code no longer requires affidavit indicating
reciever is hydrostactically tested and defect free.
HOWEVER, test every 5 years at a minimum is reccomended.
Cleaning Compressor - ANSWER -only using soap and water solution.
NEVER use benzene, kerosene or other light oils for this purpose. They may cause
an explosion when mixed w/ air under pressure.
Both oil and water can cause an explosion if they actually enter the compressor
tank.
Maintenance-Cooling System - ANSWER -Tested every 6 months.
Water supply control valves always open when compressor in operation
Maintenance-Air Intake Filter - ANSWER -Inspected/cleaned weekly.
Replaced every 6 months.
Replace if damaged
Maintenance-Lubrication Oil - ANSWER -Level checked weekly using dipstick
Replaced every 6 months
Refer to manufacturer manual for safe operating temperatures of oil and grade of
oil needed.
Maintenance-Automatic Low level Oil Indicator Switch - ANSWER -Tested every
3 months by manually draining oil from compressor. Do not run compressor for a
long period of time when testing this way.
Maintenance-Air Reciever - ANSWER -Tested every 5 years by qualified
technician
Water buildup in moisture separator assembly and air receiver drained daily by
opening drain valve EXCEPT when temperature below 40 degrees