NICET Level 2 NFPA 25: Standard for Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems 2025/2026
Chapter 1 Administration
Chapter 2 Referenced Publications (Other NFPA Standards)
Chapter 3 Definitions
Chapter 4 General Requirements (Owner's Chapter)
Sprinkler Systems (Heads, Hangers, Waterflow Alarm Devices, AF Systems, Dry
Chapter 5 Pipe Systems)
Chapter 6 Standpipe & Hose Systems
Chapter 7 Hydrants (Private Fire Service Mains)
Chapter 8 Fire Pumps
Chapter 9 Water Storage Tanks
Chapter 10 Water Spray Fixed Systems
Chapter 11 Foam-Water Sprinkler Systems
Chapter 12 Water Mist Systems
Chapter 13 Common Components and Valves
Chapter 14 Internal Piping Condition and Obstruction Investigation
Chapter 15 Impairments
MIC Deposits (What Section) Annex D (2.7)
Annually (8.3.6.4)
Parallel & Angular Alignment of Fire Pumps
to be Inspected?
3 Years (13.4.4.2.3.3
Full flow trip tests of Deluge Valve shall not
exceed _____?
Deficiency Classifications Annex A
Working Pressure of a standpipe? 6.3.2.1
Quick opening device requires testing? 13.4.5.2.4
Partial flow test on a master pressure 13.5.4.2
regulating device?
(13.6.2.1)
Class I & Class III standpipe system hose
valves require testing _____ by _____
Air compressor to be inspection ________ (13.10.2.1)
Two types of nitrogen generation PSA (Pressure Swing Adsorption) & Membrane Separation
(5.3.3.1)
Test antifreeze at which 2 points of
system?
(9.4.6.2)
Clean & Paint exposed surfaces of an
ESCF Tank?
13.2.7.2
Gauges not accurate to within __ of full
scale shall be _____?
14.4
Internal inspection on piping of pre-action
system that passes through a -10 degree
freezer?
9.5.2.3
Strainer on an automatic tank fill valve
needs to be cleaned ____?
9.3.1
Mercury gauge used as a level indicator on
a water storage tank to be tested ____?
Chapter 1 Administration
Chapter 2 Referenced Publications (Other NFPA Standards)
Chapter 3 Definitions
Chapter 4 General Requirements (Owner's Chapter)
Sprinkler Systems (Heads, Hangers, Waterflow Alarm Devices, AF Systems, Dry
Chapter 5 Pipe Systems)
Chapter 6 Standpipe & Hose Systems
Chapter 7 Hydrants (Private Fire Service Mains)
Chapter 8 Fire Pumps
Chapter 9 Water Storage Tanks
Chapter 10 Water Spray Fixed Systems
Chapter 11 Foam-Water Sprinkler Systems
Chapter 12 Water Mist Systems
Chapter 13 Common Components and Valves
Chapter 14 Internal Piping Condition and Obstruction Investigation
Chapter 15 Impairments
MIC Deposits (What Section) Annex D (2.7)
Annually (8.3.6.4)
Parallel & Angular Alignment of Fire Pumps
to be Inspected?
3 Years (13.4.4.2.3.3
Full flow trip tests of Deluge Valve shall not
exceed _____?
Deficiency Classifications Annex A
Working Pressure of a standpipe? 6.3.2.1
Quick opening device requires testing? 13.4.5.2.4
Partial flow test on a master pressure 13.5.4.2
regulating device?
(13.6.2.1)
Class I & Class III standpipe system hose
valves require testing _____ by _____
Air compressor to be inspection ________ (13.10.2.1)
Two types of nitrogen generation PSA (Pressure Swing Adsorption) & Membrane Separation
(5.3.3.1)
Test antifreeze at which 2 points of
system?
(9.4.6.2)
Clean & Paint exposed surfaces of an
ESCF Tank?
13.2.7.2
Gauges not accurate to within __ of full
scale shall be _____?
14.4
Internal inspection on piping of pre-action
system that passes through a -10 degree
freezer?
9.5.2.3
Strainer on an automatic tank fill valve
needs to be cleaned ____?
9.3.1
Mercury gauge used as a level indicator on
a water storage tank to be tested ____?