100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

STATIONARY ENGINEER EXAM NEWEST 2025 COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!!

Rating
-
Sold
-
Pages
18
Grade
A+
Uploaded on
05-11-2025
Written in
2025/2026

STATIONARY ENGINEER EXAM NEWEST 2025 COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+||BRAND NEW VERSION!!

Institution
STATIONARY ENGINEER
Course
STATIONARY ENGINEER










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
STATIONARY ENGINEER
Course
STATIONARY ENGINEER

Document information

Uploaded on
November 5, 2025
Number of pages
18
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • stationary engineer exam

Content preview

STATIONARY ENGINEER EXAM NEWEST 2025 COMPLETE QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+||BRAND NEW VERSION!!




After water is blown out of a siphon, why should live steam never be allowed to enter a Bourdon tube?

A. The steam will rupture the siphon tube.

B. Combustion gases will mix with the steam.

C. Live steam will damage the pressure gauge.

D. The water level gauge will be damaged or destroyed. - CORRECT ANSWER-C. Live steam will
damage the pressure gauge.



All of the following are essential to maintain the proper fuel oil pressure with fuel oil accessories EXCEPT

A. achieving the right flow of fuel.

B. proper atomization of the fuel oil.

C. heating fuel oil to the correct temperature.

D. obtaining the correct difference in pressure inside and outside the boiler. - CORRECT ANSWER-D.
obtaining the correct difference in pressure inside and outside the boiler.



Which of the following could be dangerous to safe operation of a low pressure boiler?

A. Adding water to an operating boiler when the water level cannot be seen in the gauge glass tube.

B. Opening the blowdown valve at the bottom of the water gauge glass before making a water level
reading.

C. Checking the water level using the try cocks valves when the line to the glass gauge tube is clogged.

,D. Opening the water column blowdown valve every day. - CORRECT ANSWER-A. Adding water to an
operating boiler when the water level cannot be seen in the gauge glass tube.



Which of the following is best if a low-pressure boiler does not have an air vent?

A. Vent the boiler with the try cocks.

B. Vent the boiler with the safety valve.

C. Vent the boiler with the fusible plug.

D. Vent the boiler with the blowdown line. - CORRECT ANSWER-A. Vent the boiler with the try cocks.


What is the purpose of an evaporation test on a low pressure boiler?

A. To test the water column

B. To test the bottom blowdown valve

C. To test the steam pressure safety valve

D. To test the low water cutoff control. - CORRECT ANSWER-D. To test the low water cutoff control.


High pressure steam boilers generally operate at pressures

A. above 15 psi and over 6 boiler horsepower.

B. below 15 psi and over 8 boiler horsepower.

C. above 250 psi and over 6 boiler horsepower.

D. at 212 psi and over 8 boiler horsepower. - CORRECT ANSWER-A. above 15 psi and over 6 boiler
horsepower.



Pressure gauges should never have a range less than

A. half the safety valve set pressure.

B. double the safety valve set pressure.

C. 3/4 times the safety valve set pressure.

D. 1 1/2 times the safety valve set pressure. - CORRECT ANSWER-D. 1 1/2 times the safety valve set
pressure.



Following flame failure, controls must de-energize fuel and ignition circuits

, A. within 4 seconds.

B. within 6 seconds.

C. within 10 seconds.

D. within 15 seconds. - CORRECT ANSWER-A. within 4 seconds.


How can an operator prevent damage to the tubes while using a cleaner to remove scale from boiler
tubes?

A. Never use a chemical cleaning procedure.

B. Never use cleaning water under pressure.

C. Never allow the cleaner to stay in one place.

D. Never clean the tubes more often than every six months. - CORRECT ANSWER-C. Never allow the
cleaner to stay in one place.



In a steam boiler, which of the following should never be placed between the safety relief valve and the
boiler?

A. A steam trap

B. A shut-off valve

C. An air eliminator

D. A discharge pipe - CORRECT ANSWER-B. A shut-off valve


Which of these should be used on live electrical fires?

A. Class D extinguishers

B. Class C extinguishers

C. Class B extinguishers

D. Class A extinguishers - CORRECT ANSWER-B. Class C extinguishers


If certain grades of fuel oil are not preheated properly, they may cause

A. higher temperatures in the furnace.

B. back pressure and leaks in the fuel lines.

C. poor combustion and high fuel consumption.
$14.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
DoctorDee

Get to know the seller

Seller avatar
DoctorDee Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
2 year
Number of followers
6
Documents
1925
Last sold
3 days ago
Hi wayne1111

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions