2025/2026 CUPID ADMIN CAR400 EXAM BANK
CURRENTLY COMPLETE TESTING QUESTIONS
AND DETAILED CORRECT ANSWERS (VERIFIED)
FOR GUARANTEED PASS TOP-RATED A+.
CUPID
Ace your CAR400 Cupid Admin exam with this targeted guide,
designed to master the configuration, customization, and management
of the Cerner Cupid cardiovascular information system. This resource
streamlines your preparation with realistic practice scenarios and
verified solutions that reflect the challenges of real-world system
administration. Efficiently build the specialized expertise needed to
pass your certification and excel in supporting critical clinical
cardiology workflows.
True/False: Setting the Trig Chgs field to Yes will prevent
charges from dropping for this procedure ...... ANSWER
....... False: Setting Trig Chgs to No will prevent charges
from dropping for the procedure.
True/False: Drop Charge at End Exam must be set to Yes
for technical charges to trigger automatically when the
technologist ends the exam, regardless of the setup on the
Context-based Charging screen. ...... ANSWER .......
True
Will the reading pool that you linked in your department
record be used for this procedure? Why or why not? ......
,2|Page
ANSWER ....... no. it will be overridden by the settings
in the procedure category
No, It will be overwritten by the reading pool linked by the
Procedure Category by the foundation system. The system
searches the most specific level 1st.
The following be set in the CV Cardiac Services Procedures
procedure category? ...... ANSWER ....... That the tilt
table procedure requires a signature from a physician with
a reading role of cardiology.
That the tilt table visit type should be used to schedule the
procedures in this category.
the following CANNOT be set in the CV Cardiac Services
Procedures procedure category ...... ANSWER .......
That procedures in this category can be found by typing
"Cardiac" in Ancillary Orders.
That a specific technical charge that should be triggered at
End Exam for procedures in this
category.
,3|Page
A procedure that is missing a visit type will result in which of
the following issues ...... ANSWER ....... Once the order
has been placed, it will not appear in the Orders Depot on
the Snapboard.
Once the order has been placed, it will not appear on the
Orders tab in the patient's
Appointment Desk.
Routing studies to the appropriate reading work list. ......
ANSWER ....... The pool that is linked to the CV
Cardiac Services Procedures procedure category will be
used
for _________.
Which procedure record contains information related to
ordering and scheduling the
exam? ...... ANSWER ....... the orderable record
contains this information. the performable record has not
been chosen yet, so it should not contain those settings
At what levels can you customize technologist navigators?
...... ANSWER ....... 1. In Imaging System Definitions, a
department, or a visit type link a NAVIGATOR
, 4|Page
template and/or a procedure-level topic.
2. In a procedure category or procedure, you can only link a
procedure-level
TOPIC.
A technologist documented using an IV needle in the
Supplies section of the End Exam Navigator. Where did that
data file? ...... ANSWER ....... Order
At which of the following levels can you attach a navigator
template to appear at Begin Exam or End Exam? ......
ANSWER ....... Department, visit type, imaging system
definitions
When performing procedures in your non-invasive
cardiology department, you want users to fill out items
regarding supplies in their navigator. No other departments
require this information, and this information should be
collected for each order that the tech performs.
You should plug a _________ in to the __________. ......
answer ....... topic; non-invasive cardiology department
A technologist calls your help desk. He needs to document
the procedure that he performed, but he's not seeing the