A chimney top should be at least _____ above the roof and _____ higher than anything within _____ feet. A. 10..... 3..... 2 B. 2..... 10..... 3 C. 3..... 2..... 10 D. 3..... 10..... 2 3..... 2..... 10 OSB Siding is a. Fiber Cement b. A type of plywood. c. A type of waferboard. d. A type of hardboard. C. A type of wafer board

Show more Read less
Institution
Home Inspection
Course
Home inspection










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Home inspection
Course
Home inspection

Document information

Uploaded on
October 24, 2025
Number of pages
19
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

National Home Inspector Exam Prep
questions and answers
Which of the following defects can result in a serious safety problem in the bathroom
✔✔Water damage on the floor around the toilet that's what

Which of the following elements is not a common characteristics of a railing system?
✔✔Balcony

What is delaminating and where is it likely to occur ✔✔It is the deterioration of wood
trim or wood surfaces on windows and doors.Noncontact moisture meter ✔✔if water is
filtration is suspected behind a finish surface. What would be the best choice to verify
dampness

Gas, fire, furnaces, heat exchanges most often fail from ✔✔Rust and fatigue

Relative humidity is expressed as ✔✔percentage

Connections of dissimilar metal in a plumbing system, such as galvanized steel pipe
and copper pipe, will usually cause ✔✔Electrolysis

An undergrounded receptacle may be replaced by a ground, fault circuit interrupter
installed ✔✔Upstream from the receptacle

Circuit breakers ✔✔protect the wire from an electrical overload

In a force air heating system, containing a split system air condition and
humidifier,humidity is reduced by ✔✔Condensation of the evaporator coil

Waterhammer can occur as a result of ✔✔A lack of air chambers

If a system designed for use with natural gas is supplied with propane gas ✔✔The
flame will be too high, unless a smaller orifice is installed

When looking at the exterior wall of a 60 year old brick masonry house with a gable
roof, you notice a horizontal crack in the mortar and outward brick displacement along
the gutter edge of the roof. The displacement is greatest at the center of the top 3
courses of brick This condition is MOST likely caused by. ✔✔Improper ceiling joist
installation

,You inspect a wood framed cantilevered balcony off of a 2nd story bedroom you find a
significant wood deterioration, of all cantilever Joists at the bearing point of the house
you should ✔✔Notify the occupants of the significant hazard advise immediate repair to
both the occupant and the client in the report

When a cooling unit is located in an attic where damage may result from condensate
overflow ✔✔An auxiliary condensate drain system is required

If poured concrete foundation has an unusually large amount of vertical cracks, each,
no wider than 1/32 inch cause likely to be ✔✔Shrinkage of the concrete from access
water at the time of pouring

Where should squash blocks web blocking, be found in the wood joist floor system
✔✔At bearing ends and low bearing walls above, with support girders below

Columns typically support ✔✔Girders

In new construction the minimum overhead electrical service clearances are
✔✔walkway: 10 feet, roadway: 18 feet, deck: 10 feet

During a summertime inspection, we could indicate chronic condensation problems in a
attic ✔✔There are no vapor retarder on the insulation

Ice damming at the eaves may be caused by ✔✔In adequate attic insulation

The purpose of flashing on a roof is to ✔✔Shed water onto roofing materials

While inspecting a heat pump is the cooling mode you measure a 28°F temperature
differential between the interior supply and return air you should suspect: ✔✔A dirty
filter

What is the minimum electric service drop clearance from a residential driveway? ✔✔12
feet

Roof truss uplift can cause cracks to form ✔✔At interior wall/ceiling intersections

When measuring the temperature drop across the evaporator in a central air
conditioning system a properly running unit on a humid summer day should read
between ✔✔15 and 25 degrees Fahrenheit

Knob and tube wiring may be acceptable if ✔✔Not covered by Installation

The maximum acceptable variation in a riser height within a flight of stairs is ✔✔3/8 inch

, While conducting an inspection, your ladder falls over and breaks the homeowners
priceless vase. What type of insurance is needed to cover the replacement?
✔✔General liability

The minimum reliable, separation between a masonry chimney and combustible
materials ✔✔2 inches

Bonding of appliances can be confirmed by using in ✔✔Ohm meter

Service panel enclosure doors is required to open at least ✔✔90°

What is a required element of a contract? ✔✔consideration

Buckling in a horizontal vinyl siding is generally caused by? ✔✔Improper fastening

At what level would water pressure with a single-family dwelling began to be considered
excessive in require correction ✔✔80 psi

A new home with electric heating is being inspected. It has a below grade finish
basement containing a bedroom the inspector should look for a smoke alarm, and.
✔✔An escape and rescue opening

A swimming pool fence must prevent passage of a sphere that is larger than ✔✔4
inches

A ground fault circuit interrupter is a safety device that ✔✔Disconnects the power when
sensing current leakage to the ground

An electric system, with a fuse on the neutral conductor, and on the energized (hot)
conductors ✔✔Is hazardous and should be corrected

To operate a central air condition, electric clothes dryer, and electric range the
amperage of the service to the house should be at least. ✔✔100 amps at 240 volts

brick chimneys on older properties with oil heat sometimes curve above the roofline with
no visible cracks. Which is the possible cause of curving? ✔✔Expansion of motar

Low pressure boiling pipes. Do not carry steam pressure above. ✔✔15 Psi

Roof Truss ✔✔Are usually designed for two point bearing

On a hillside house with foundation drain systems, ✔✔The foundation drain system
collect water, passing laterally through the slope
$14.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Gnurse

Get to know the seller

Seller avatar
Gnurse NEWCASTLE UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
1 year
Number of followers
0
Documents
213
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions