100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

DHYG 1304 - Final Exam Review Questions and Answers Already Passed

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
22-10-2025
Written in
2025/2026

DHYG 1304 - Final Exam Review Questions and Answers Already Passed Not recording the apical structures is a _____ error - Answers technique error Probable cause for not recording apical structures: - Answers -image receptor not place high/low enough -patient didn't occlude completely -inadequate vertical angulation Corrective actions for not recording apical structures: - Answers -ensure receptor is positioned correctly and patient is biting down all of the way (tip receptor into midline of mouth) -increase vertical angulation no greater than 15 degrees Cutting off incisial/occlusal surface is a _____ error - Answers technique error Probable cause of cutting off incisial/occlusal surface: - Answers excessive vertical angulation Corrective actions of cutting off incisal/occlusal surface: - Answers decrease angulation no greater than 15 degrees Dark images is a _____ error - Answers technique error and processing error Probable causes of dark images (technique error): - Answers -excessive exposure time (overexposure) -rarely the result of equipment malfunction Probable causes of dark images (processing error): - Answers -film is left in the developer too long -incorrectly mixing the developer (too strong) Corrective action for dark images (technique error): - Answers decrease the exposure settings Light images is a _____ error - Answers technique error and processing error Probable cause of light images (technique error): - Answers -check for reversed film error -insufficient exposure time -failure to press exposure button for full duration -rarely the result of equipment malfunction Probable cause for light images (processing error): - Answers -film is not left in developer long enough -incorrectly mixing developer solution (too weak) Corrective actions for light images (technique error): - Answers increase exposure setting Overlapping is a _____ error - Answers technique error Probable causes of overlapping: - Answers -incorrect rotation of the tube head and PID in the horizontal plane -not positioning the image receptor parallel to the interproximal spaces of the teeth Corrective actions for overlapping: - Answers -examine to determine if overlap is more sever in anterior or posterior region (to correct mesiodistal overlap, rotate tube head and PID to direct

Show more Read less
Institution
DHYG 1304
Course
DHYG 1304









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
DHYG 1304
Course
DHYG 1304

Document information

Uploaded on
October 22, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

DHYG 1304 - Final Exam Review Questions and Answers Already Passed

Not recording the apical structures is a _____ error - Answers technique error

Probable cause for not recording apical structures: - Answers -image receptor not place
high/low enough

-patient didn't occlude completely

-inadequate vertical angulation

Corrective actions for not recording apical structures: - Answers -ensure receptor is positioned
correctly and patient is biting down all of the way (tip receptor into midline of mouth)

-increase vertical angulation no greater than 15 degrees

Cutting off incisial/occlusal surface is a _____ error - Answers technique error

Probable cause of cutting off incisial/occlusal surface: - Answers excessive vertical angulation

Corrective actions of cutting off incisal/occlusal surface: - Answers decrease angulation no
greater than 15 degrees

Dark images is a _____ error - Answers technique error and processing error

Probable causes of dark images (technique error): - Answers -excessive exposure time
(overexposure)

-rarely the result of equipment malfunction

Probable causes of dark images (processing error): - Answers -film is left in the developer too
long

-incorrectly mixing the developer (too strong)

Corrective action for dark images (technique error): - Answers decrease the exposure settings

Light images is a _____ error - Answers technique error and processing error

Probable cause of light images (technique error): - Answers -check for reversed film error

-insufficient exposure time

-failure to press exposure button for full duration

-rarely the result of equipment malfunction

Probable cause for light images (processing error): - Answers -film is not left in developer long
enough

, -incorrectly mixing developer solution (too weak)

Corrective actions for light images (technique error): - Answers increase exposure setting

Overlapping is a _____ error - Answers technique error

Probable causes of overlapping: - Answers -incorrect rotation of the tube head and PID in the
horizontal plane

-not positioning the image receptor parallel to the interproximal spaces of the teeth

Corrective actions for overlapping: - Answers -examine to determine if overlap is more sever in
anterior or posterior region (to correct mesiodistal overlap, rotate tube head and PID to direct
central rays more toward anterior teeth)

-place image receptor parallel to contact points of teeth

Elongation is a _____ error - Answers technique error

Probable cause of elongation: - Answers insufficient vertical angulation

Corrective actions for elongation: - Answers increase vertical angulation

Foreshortening is a _____ error: - Answers technique error

Probable cause of foreshortening: - Answers excessive vertical angulation

Corrective actions for foreshortening: - Answers decrease vertical angulation

Brown film is a _____ error - Answers processing error

Probable causes of brown film: - Answers insufficient washing, chemicals remain on surface
and erode the image

Corrective actions for brown film: - Answers -rinse films for at least 20 minutes

-make sure water supply is full and turned one

Clear/blank film is _____ error - Answers technique error and processing error

Probable cause of clear/blank film (technique error): - Answers -no exposure to x-rays

-incorrect side of PSP plate or sensor exposed

-equipment malfunction

Probable cause of clear/blank film (processing error): - Answers -accidentally placed in fixer
before developer

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
joshuawesonga22 Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
34
Member since
8 months
Number of followers
1
Documents
10962
Last sold
1 week ago
Tutor Wes

Hi there! I'm Tutor Wes, a dedicated tutor with a passion for sharing knowledge and helping others succeed academically. All my notes are carefully organized, detailed, and easy to understand. Whether you're preparing for exams, catching up on lectures, or looking for clear summaries, you'll find useful study materials here. Let’s succeed together!

3.3

3 reviews

5
1
4
0
3
1
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions