100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Apprentice Lineman Transformer Theory Test Questions With Complete Answers

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
17-10-2025
Written in
2025/2026

Apprentice Lineman Transformer Theory Test Questions With Complete Answers .Why is a Closed Wye - Closed Delta primary neutral floated? - Answer-To prevent the backfeed of full primary voltage if a line cutout is blown. .Why is a 4th cutout installed on the primary neutral of a closed Wye -closed Delta Bank? - Answer-To prevent Ferroresonance while switching. .On an open transformer bank, what KVA capacity is the bank rated for? - Answer-86.6% of nameplate ratings. .Expain the term "Backfeed" - Answer-Feeding the primary coil through the secondary coil. .What must be done before climbing above a transformer? - Answer-Make sure the tank ground is intact, de-energize the high side and remove secondary leads. .What determines the amount of voltage drop when a transformer is fully loaded? - Answer-Impedance .Explain polarity of a transformer. - Answer-Relative direction of current flow primary to secondary. .When paralleling or banking transformers, the impedance must be within _____% of each other? - Answer-10% .What KVA capacity would you have if you convert a closed delta bank to an open delta bank? - Answer-57.7% of the original 3 transformers. OR 86.6 of the remaining 2. .How much capacity would you gain from using a closed delta bank instead of an open delta bank? - Answer-(57.7 to 100%) = 42.3% .What do you need to do with the neutral connection on a closed wye -closed wye transformer bank? - Answer-Tie the primary neutral. .What purpose does the case ground serve on a transformer? - Answer-To make sure the transformer case doesn't become energized, and on a single bushing transformer the case ground is the H2 connection. .Name the types of transformer banks you can make with two or three transformers. - Answer-Wye-Wye, Wye-Delta, Delta-Delta, Delta-Wye, Open Wye-Delta, Open Delta-Delta .What does CSP mean? - Answer-Completely self protected .On a CSP transformer, what coil is the circuit breaker on? - Answer-Secondary .Taps are used for two purposes, name them. - Answer-Control voltage to the customer and correct low primary voltage *raise the tap to lower the secondary voltage* .T or F, Two cutouts and arrestors are needed on a wye connected transformer. - Answer-FALSE

Show more Read less
Institution
Apprentice Lineman Transformer Theory
Course
Apprentice Lineman Transformer Theory









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Apprentice Lineman Transformer Theory
Course
Apprentice Lineman Transformer Theory

Document information

Uploaded on
October 17, 2025
Number of pages
5
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Apprentice Lineman Transformer
Theory Test Questions With Complete
Answers



\.Why is a Closed Wye - Closed Delta primary neutral floated? - Answer- To prevent the
backfeed of full primary voltage if a line cutout is blown.



\.Why is a 4th cutout installed on the primary neutral of a closed Wye -closed Delta Bank? -
Answer- To prevent Ferroresonance while switching.



\.On an open transformer bank, what KVA capacity is the bank rated for? - Answer- 86.6% of
nameplate ratings.



\.Expain the term "Backfeed" - Answer- Feeding the primary coil through the secondary coil.



\.What must be done before climbing above a transformer? - Answer- Make sure the tank
ground is intact, de-energize the high side and remove secondary leads.



\.What determines the amount of voltage drop when a transformer is fully loaded? - Answer-
Impedance



\.Explain polarity of a transformer. - Answer- Relative direction of current flow primary to
secondary.

, \.When paralleling or banking transformers, the impedance must be within _____% of each
other? - Answer- 10%



\.What KVA capacity would you have if you convert a closed delta bank to an open delta bank? -
Answer- 57.7% of the original 3 transformers. OR 86.6 of the remaining 2.



\.How much capacity would you gain from using a closed delta bank instead of an open delta
bank? - Answer- (57.7 to 100%) = 42.3%



\.What do you need to do with the neutral connection on a closed wye -closed wye transformer
bank? - Answer- Tie the primary neutral.



\.What purpose does the case ground serve on a transformer? - Answer- To make sure the
transformer case doesn't become energized, and on a single bushing transformer the case
ground is the H2 connection.



\.Name the types of transformer banks you can make with two or three transformers. - Answer-
Wye-Wye, Wye-Delta, Delta-Delta, Delta-Wye, Open Wye-Delta, Open Delta-Delta



\.What does CSP mean? - Answer- Completely self protected



\.On a CSP transformer, what coil is the circuit breaker on? - Answer- Secondary



\.Taps are used for two purposes, name them. - Answer- Control voltage to the customer and
correct low primary voltage *raise the tap to lower the secondary voltage*



\.T or F, Two cutouts and arrestors are needed on a wye connected transformer. - Answer-
FALSE
$8.09
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
IszackBd
5.0
(1)

Also available in package deal

Thumbnail
Package deal
Lineman Apprentice Exams Package Deal
-
9 2025
$ 117.51 More info

Get to know the seller

Seller avatar
IszackBd University Of Washington
View profile
Follow You need to be logged in order to follow users or courses
Sold
7
Member since
1 year
Number of followers
1
Documents
2593
Last sold
2 days ago
IszackBd Stuvia

Our store offers a wide selection of materials on various subjects and difficulty levels, created by experienced teachers. We specialize on NURSING,WGU,ACLS USMLE,TNCC,PMHNP,ATI and other major courses, Updated Exam, Study Guides and Test banks. If you don't find any document you are looking for in this store contact us and we will fetch it for you in minutes, we love impressing our clients with our quality work and we are very punctual on deadlines. Please go through the sets description appropriately before any purchase and leave a review after purchasing so as to make sure our customers are 100% satisfied. FOR ANY REQUEST FEEL FREE TO REACH US

Read more Read less
5.0

1 reviews

5
1
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions