sprinkler test questions with correct answers
/ // // // // //
fire /
/department /
/connection //- /
/CORRECT /
/ANSWERS(S)✔✔normally /
/on /
/exterior /
/of /
/building... /
/FDNY /
/can /
/pump /
/supplemental /
/water /
/into /
/the /
/sprinkler //system, //standpipe, //or //other //system //furnishing //water //for //fire //extinguishment //to
//supplement //existing //water //supplies.
system //control //valve //- //CORRECT //ANSWERS(S)✔✔valve //controlling //flow //to //water-
based //fire //protection //systems.
fire //command //center //- //CORRECT //ANSWERS(S)✔✔...
MFSPC //- //CORRECT //ANSWERS(S)✔✔...
MLP //- //CORRECT //ANSWERS(S)✔✔...
,tags //- /
/CORRECT /
/ANSWERS(S)✔✔on /
/closed /
/section /
/valves /
/serving /
/affected /
/areas: /
/area /
/affected, /
/brief /
/description, //occupancy //classification, //c //of //f //number, //estimated //time //until //operational
Green /
/tag //- /
/CORRECT //ANSWERS(S)✔✔no //impairment //found //in //entire //system- //main //control //valve
white /
/tag //- /
/CORRECT //ANSWERS(S)✔✔fully //out //of //service- //place //on //all //fire //department //connecitons
red /
/tag //- /
/CORRECT /
/ANSWERS(S)✔✔place /
/on /
/main /
/control //valve //if //FULLY //OR //PARTIALLY //out //of //service... //put //sprinkler //company //name, //date
//of //removal //from //service //and //anticipated //time //to //operational
,blue /
/disk //- /
/CORRECT //ANSWERS(S)✔✔partially //out //of //service- //on //all //fire //department //connections
water //storage //tank //- //CORRECT //ANSWERS(S)✔✔...
OS //
& //
Y/
/valve //- /
/CORRECT //ANSWERS(S)✔✔indicating //type //of //control //valve //used //for //fire //sprinkler //system
deluge /
/valve //- /
/CORRECT /
/ANSWERS(S)✔✔water /
/supply /
/control /
/valve /
/intended /
/to /
/be /
/operated /
/by /
/actuation /
/of /
/an /
/automatic /
/detection //system //that //is //installed //in //the //same //area //as //the //discharge //devices. //INTENDED
//USE //IS //MANUAL //AND //AUTO
deluge /
/sprinkler /
/system //- /
, /CORRECT /
/ANSWERS(S)✔✔employing /
/open /
/sprinklers /
/that /
/are /
/attached /
/to //a //piping //system //that //is //connected //to //a //water //supply //through //a //valve //that //is //opened
//by /
/the /
/operation //of //a //detection //system //installed //in //the //same //areas //as //the //sprinklers. //WHEN //IT
//OPENS, //water //flows //into //the //piping //system //and //discharges //from //all //sprinklers //attached.
Early /
/suppresion /
/fast /
/response /
/sprinklers //- /
/CORRECT /
/ANSWERS(S)✔✔fast /
/response /
/sprinkler /
/that /
/is /
/listed /
/for //its //capability //to //provide //fire //suppression //of //specific //high //challenge //fire //hazards
extra /
/large /
/orifice /
/sprinklers //- /
/CORRECT /
/ANSWERS(S)✔✔= //or //> //1 //inch //less //pressure //to //achieve //a //given //discharge //density
extended //coverage //sprinkler //- //CORRECT //ANSWERS(S)✔✔400 //max //square //feet //discharge