Never attempt to "jump" or connect a battery charger to a (x) battery - Answer-frozen (it
will explode!)
any battery circuit with 801 CCA or more requires a ... - Answer-battery switch
Batteries shall not be installed directly (x) or (x) a fuel tank, fuel filter, or fitting in a fuel
line without an intervening sole, floor, or deck - Answer-above or below
battery cables and other conductors size 6 AWG and larger shall not be connected to
the battery with... - Answer-wing nuts
a maximum of (x) conductors will be placed on any one battery terminal - Answer-4
What is a historical issue when technicians are mounting new alternators which cause
to overheating? Hint: the diodes need to be kept cool! - Answer-A unidirectional fan on
the alternator is installed backwards!
true or false: a diesel engine requires an ignition system for start up - Answer-False;
only a strong starter and charging system to keep the battery up to charge
what rating on a battery switch must not be less than the maximum cranking current of
the largest engine cranking motor that it serves - Answer-The 30 second rating
a clearance of (x) inches between conductors and WATER COOLED exhaust
components and a clearance of (x) inches between conductors and DRY exhaust
components will be maintained - Answer-2 inches; 9 inches
conductors shall not be installed directly above a ..... - Answer-dry exhaust
each glow plug draws about how many amps - Answer-5 amps
200 rpm difference can be expected for each (x) inch of pitch change - Answer-one
a plate who's purpose is to keep water surface gasses (air) from getting down to the
propeller just below the plate - Answer-anti-ventilation plate
Seawater Cooling Systems and Closed
Cooling Systems QUESTIONS
Never attempt to "jump" or connect a battery charger to a (x) battery - Answer-frozen (it
will explode!)
any battery circuit with 801 CCA or more requires a ... - Answer-battery switch
Batteries shall not be installed directly (x) or (x) a fuel tank, fuel filter, or fitting in a fuel
line without an intervening sole, floor, or deck - Answer-above or below
battery cables and other conductors size 6 AWG and larger shall not be connected to
the battery with... - Answer-wing nuts
a maximum of (x) conductors will be placed on any one battery terminal - Answer-4
What is a historical issue when technicians are mounting new alternators which cause
to overheating? Hint: the diodes need to be kept cool! - Answer-A unidirectional fan on
the alternator is installed backwards!
true or false: a diesel engine requires an ignition system for start up - Answer-False;
only a strong starter and charging system to keep the battery up to charge
what rating on a battery switch must not be less than the maximum cranking current of
the largest engine cranking motor that it serves - Answer-The 30 second rating
a clearance of (x) inches between conductors and WATER COOLED exhaust
components and a clearance of (x) inches between conductors and DRY exhaust
components will be maintained - Answer-2 inches; 9 inches
conductors shall not be installed directly above a ..... - Answer-dry exhaust
each glow plug draws about how many amps - Answer-5 amps
200 rpm difference can be expected for each (x) inch of pitch change - Answer-one
a plate who's purpose is to keep water surface gasses (air) from getting down to the