Oil Burners License Test Exam With 100% Correct Answers 2025/2026
Oil Burners License Test Exam With 100% Correct Answers 2025/2026 The main function of the primary control is: - answer-Locking out on safety in the event of flame failure Power must be provided to an electric blower control board on terminals: - answer-L1 and L2 Once a PSC motor starts - answer-The centrifugal switch turns off the electricity to the capacitor and the start windings Materials who's electrons are so loosely bound that they can be persuaded to move with very little pressure allowing electricity to flow are called - answer-Conductors Oil burners can make CO even when no smoke is present - answer-True Corrosion in the flu pipe may occur if - answer-Flue gas temperature is below the dewpoint and sulfur oxide's combine with water To avoid condensing and the flu pipe and oil fired appliance should have a minimum growth stock temperature of - answer-350°F All persons assisting and working under the supervision of a person holding a certificate as an oil burner technician must hold current apprentice certificates issued by Department of fire services - answer-True What size pipe is used to cross connect tank outlets piping - answer-1/2 inchFuel return piping from an appliance shall - answer-Enter the top of the tank Delayed ignition may be caused by - answer-Unvented pressure regulator Installation of oil safety valves and oil pressure reducing valve - answer-Reduces the chance of a return line leak What is an installation - answer-Complete and ready for operation of any oil burning appliance Energizing the ignition circuit during the entire burn cycle reduces - answer-Ignition component life Fuel can be transferred from a tank to an appliance by pressurizing the tank - answer-False What device must be equipped with an air proving switch - answer-Both, draft inducers and powerventers What is a safety control - answer-Any control used to prevent unsafe operation of the controlled equipment A non-resident steam or hot water boiler having a minimum safety relief valve capacity over 200,000 BTU/hr requires certificate of inspection from the department of fire services - answer-Prior to the initial firing, every 3 years after What is the closest distance a supply tank can be to the burner - answer-5 feet Doing a combustion pretest on and oil burning appliance will not tell you anything this is why they generally are performed - answer-False What is the minimum oil supply line size for a residential system - answer-3/8 inch
Written for
- Institution
- Oil Burners License
- Course
- Oil Burners License
Document information
- Uploaded on
- October 1, 2025
- Number of pages
- 6
- Written in
- 2025/2026
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
oil burners license test exam with 100 correct an
Also available in package deal