NICET Level II Certification Fire Alarm Systems Actual Exam 2025/2026 100 Questions Complete with Detailed Explanations & Code References

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
01-10-2025
Written in
2025/2026

Questions 1-20 | NFPA 72, IBC, ADA Requirements Question 1 According to NFPA 72, what is the maximum spacing for smoke detectors in a smooth ceiling? A) 20 feet B) 30 feet C) 40 feet D) 50 feet EXPLANATION NFPA 72-17.7.3.2.3.1 - Smoke detectors on smooth ceilings have a maximum spacing of 30 feet (9.1m) center-to-center. This assumes 30-foot diameter coverage area per detector with proper overlap. KEY POINT Spacing may be reduced for irregular ceilings, beams, joists, or air handling considerations. Always consider ceiling height and configuration. Question 2 What is the minimum height for wall-mounted visual notification appliances (strobes)? A) 60 inches B) 70 inches C) 80 inches D) 90 inches EXPLANATION NFPA 72-18.5.5.1 - Wall-mounted visual appliances must be mounted with the entire lens between 80 inches (2.0m) minimum and 96 inches (2.4m) maximum above the finished floor. This ensures visibility for all occupants. Question 3 What is the required flash rate for visual notification appliances? A) 0.5 to 1 Hz B) 1 to 2 Hz C) 2 to 3 Hz D) 3 to 4 Hz EXPLANATION NFPA 72-18.5.2.1 - Visual notification appliances must flash at a rate of 1 to 2 flashes per second (1 to 2 Hz). This rate is optimal for alerting occupants without triggering photosensitive epilepsy. ️ IMPORTANT Synchronization of strobes is required when multiple devices are visible in the same field of view to prevent disorientation. Question 4 How often must fire alarm systems be tested and inspected? A) Annually B) Semi-annually C) Quarterly D) Monthly EXPLANATION NFPA 72-14.3.1 - Complete fire alarm system testing and inspection must be performed at least annually. Some components require more frequent testing (e.g., battery tests, backup power monthly; alarm notification appliance semi-annually). Question 5 What is the maximum distance from any point in a corridor to a manual pull station? A) 100 feet B) 150 feet C) 200 feet D) 250 feet

Show more Read less
Institution
Revision
Course
Revision









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Revision
Course
Revision

Document information

Uploaded on
October 1, 2025
Number of pages
7
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NICET
Level II Certification
Fire Alarm Systems
Practice Exam 2025/2026
100 Questions
Complete with Detailed Explanations & Code References

PART 1: CODES & STANDARDS
Questions 1-20 | NFPA 72, IBC, ADA Requirements
Question 1
According to NFPA 72, what is the maximum spacing for smoke detectors in a
smooth ceiling?
A) 20 feet
B) 30 feet
C) 40 feet
D) 50 feet
💡 EXPLANATION

NFPA 72-17.7.3.2.3.1 - Smoke detectors on smooth ceilings have a maximum spacing of 30
feet (9.1m) center-to-center. This assumes 30-foot diameter coverage area per detector with proper
overlap.
✓ KEY POINT

Spacing may be reduced for irregular ceilings, beams, joists, or air handling considerations. Always consider ceiling
height and configuration.
Question 2
What is the minimum height for wall-mounted visual notification appliances
(strobes)?
A) 60 inches
B) 70 inches
C) 80 inches

, D) 90 inches
💡 EXPLANATION

NFPA 72-18.5.5.1 - Wall-mounted visual appliances must be mounted with the entire lens between 80
inches (2.0m) minimum and 96 inches (2.4m) maximum above the finished floor. This ensures visibility
for all occupants.
Question 3
What is the required flash rate for visual notification appliances?
A) 0.5 to 1 Hz
B) 1 to 2 Hz
C) 2 to 3 Hz
D) 3 to 4 Hz
💡 EXPLANATION

NFPA 72-18.5.2.1 - Visual notification appliances must flash at a rate of 1 to 2 flashes per second (1
to 2 Hz). This rate is optimal for alerting occupants without triggering photosensitive epilepsy.
⚠️ IMPORTANT

Synchronization of strobes is required when multiple devices are visible in the same field of view to prevent
disorientation.
Question 4
How often must fire alarm systems be tested and inspected?
A) Annually
B) Semi-annually
C) Quarterly
D) Monthly
💡 EXPLANATION

NFPA 72-14.3.1 - Complete fire alarm system testing and inspection must be performed at
least annually. Some components require more frequent testing (e.g., battery tests, backup power
monthly; alarm notification appliance semi-annually).
Question 5
What is the maximum distance from any point in a corridor to a manual pull
station?
A) 100 feet
B) 150 feet
C) 200 feet
D) 250 feet

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Abbyy01 Exam Questions
View profile
Follow You need to be logged in order to follow users or courses
Sold
91
Member since
3 year
Number of followers
33
Documents
1121
Last sold
3 weeks ago

3.5

13 reviews

5
5
4
2
3
3
2
1
1
2

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions