Prepare for the TFM12 exam with this complete 91-question multiple choice practice test. The questions are written to closely reflect the style and scope of the actual Texas Fire Alarm Technical Exam, covering NFPA 72, inspection and testing requirements, detector technology, communication systems, and code compliance. This practice test is designed for technicians, contractors, and inspectors who are seeking their Texas fire alarm license through the Department of Insurance (TDI). Use this exam to measure your readiness and strengthen your understanding of fire alarm systems before sitting for the official TFM12.

Show more Read less
Institution
TFM12
Course
TFM12









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
TFM12
Course
TFM12

Document information

Uploaded on
September 29, 2025
File latest updated on
September 29, 2025
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

TFM12 Practice Exam – Multiple Choice (91 Questions)



1. How many fire alarm boxes (pull stations) are required in systems employing automatic fire or water flow
detectors?
A. None if detectors are present
B. One on every floor regardless of AHJ
C. At least one, located where required by the AHJ
D. Two at each exit door

2. Systems that require two automatic detectors to initiate the alarm may only be used after which 3 conditions
are filled?
A. Only when detectors are photoelectric, wiring is supervised, and AHJ is notified
B. Allowed by AHJ, two detectors in each protected space, no alarm verification used
C. If all detectors are ionization type, placed in each hallway, and audible test performed
D. Requires AHJ approval, alarm verification required, detectors in exit paths only

3. The number of water flow switches permitted to be connected to a single initiating device shall not exceed:
A. 3
B. Unlimited
C. 10
D. 5

4. What must be monitored for integrity?
A. Installation wiring between the fire alarm control unit and the appliance
B. Elevator recall relays only
C. Control panel internal circuits only
D. All conductors inside conduit

5. Each elevator lobby, elevator hoist way and elevator machine room detector must be capable of what?
A. Initiating elevator recall
B. Shutting down HVAC systems
C. Triggering fire doors to close
D. Activating voice evacuation messages

6. Must the alarm devices within the elevator hoist way be integrated with the fire alarm?
A. Only when the AHJ approves
B. Only in buildings over 3 stories
C. Yes
D. No

, 7. Wall mounted appliances must be located between which two distances above a finished floor?
A. 100–120 inches
B. 72–84 inches
C. 60–72 inches
D. 80–96 inches

8. When may the manual testing frequency be extended to annually?
A. Only when detectors are ionization type
B. When AHJ waives the requirement
C. If smoke detectors are tested monthly
D. If automatic testing is performed at least weekly

9. The responsibility for inspections, tests, and maintenance programs shall be assigned by the ______ to a
designated person of authority.
A. AHJ
B. Fire marshal
C. Owner
D. Building engineer

10. Room sizes and contours, airflow patterns, obstructions, and other characteristics of the ______ shall be taken
into account.
A. Egress pathway
B. Protected hazard
C. HVAC system
D. Occupied area

11. What is the maximum voltage permitted through multi-conductor N.P.L.F.A cables?
A. 300 volts
B. 120 volts
C. 150 volts
D. 600 volts

12. What is the voltage rating marked on P.L.F.A cables?
A. Not less than 300 volts
B. Not less than 150 volts
C. 120 volts
D. Not less than 600 volts

13. Shall the voltage rating be marked on P.L.F.A cables?
A. Only if AHJ requires
B. No, because they may be mistakenly used for electrical applications
C. Yes, always
D. Only if over 150 volts
$20.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
seanrules

Get to know the seller

Seller avatar
seanrules fdgfd
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
3 months
Number of followers
0
Documents
1
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions