100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Fire Alarm Sys, Lvl I- 2023 Lesson 9: IPSI Sample Exam Fire Alarm Certification Program Level 1 Interior Quiz for Lesson 9 102Q&A

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
27-09-2025
Written in
2025/2026

Fire Alarm Sys, Lvl I- 2023 Lesson 9: IPSI Sample Exam Fire Alarm Certification Program Level 1 Interior Quiz for Lesson 9 102Q&A Prepare for the Fire Alarm Systems Level I exam with this essential study guide. Includes core concepts on system installation, components, maintenance, and basic NFPA standards. Perfect for beginners entering the fire protection industry or pursuing NICET certification." The word "Listed" means ? . sed by authority d to a product standard by a "government agency" laboratory and published in a directory d to a product standard by a laboratory and published in a directory d by an authority having jurisdiction (AHJ) and published in a directory ...... ANSWER....... c. tested to a product standard by a laboratory and published in a directory The "Scope Statement" of a fire alarm specification relates to the coordinating of other specifications. T/F ...... ANSWER ....... false Chapter ? of NFPA 72—2022 provides requirements for inspection, testing, and maintenance of fire alarm systems. a.7 b.9 c.11 d.14 ...... ANSWER ....... 14 The nominal spacing of spot type smoke detectors is ? . a.12' b.15' c.21' d.30' ...... ANSWER ....... 30'

Show more Read less
Institution
Nursing
Course
Nursing










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Nursing
Course
Nursing

Document information

Uploaded on
September 27, 2025
Number of pages
16
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • fire alarm sys lvl i

Content preview

Fire Alarm Sys, Lvl I - 2023 Lesson 9: IPSI Sample
Exam
Fire Alarm Certification Program Level 1 Interior
Quiz for Lesson 9 102Q&A
Prepare for the Fire Alarm Systems Level I exam with this essential study guide. Includes core
concepts on system installation, components, maintenance, and basic NFPA standards. Perfect
for beginners entering the fire protection industry or pursuing NICET certification."
The word "Listed" means ? .
a.endorsed by authority
b.tested to a product standard by a "government agency" laboratory and published in a
directory
c.tested to a product standard by a laboratory and published in a directory
d.tested by an authority having jurisdiction (AHJ) and published in a directory ......
ANSWER ....... c. tested to a product standard by a laboratory and published in a directory

The "Scope Statement" of a fire alarm specification relates to the coordinating of other
specifications. T/F ...... ANSWER ....... false

Chapter ? of NFPA 72—2022 provides requirements for inspection, testing, and maintenance
of fire alarm systems.
a.7
b.9
c.11
d.14 ...... ANSWER ....... 14

The nominal spacing of spot type smoke detectors is ? .
a.12'
b.15'
c.21'
d.30' ...... ANSWER ....... 30'

A circuit that has conductors returning to the control unit from the last device is best described
as a ? circuit.
a.Class 3
b.Class A
c.Class B
d.Style 4 ...... ANSWER ....... CLASS A

The sum of all voltage in a series loop circuit is the ? .
a.product over the sum
b.reciprocal of the sum of the voltages
c.same value throughout the circuit
d.sum of the individual voltages ...... ANSWER ....... d.
sum of the individual voltages

,Smoke detectors must be installed within ? of the centerline of elevator doors they control.
a.12'
b.15'
c.21'
d.30' ...... ANSWER ....... 21'

According to Article 760 of the NEC, fire alarm conductors must be protected from mechanical
damage when the cable is installed within ? of the finished floor.
a.7'
b.7.5'
c.8'
d.10' ...... ANSWER ....... a. 7'

Heat detector spacing on joisted ceilings must be reduced by ? perpendicular to the joists.
a.25%
b.33%
c.50%
d.66% ...... ANSWER ....... 50%

A 30-candela strobe covers a maximum area of ? when centered on a wall.
a.20' x 20'
b.25' x 25'
c.28' x 28'
d.40' x 40' ...... ANSWER ....... 28' x 28'

An emergency voice/alarm communications system must have a minimum standby capacity of
48 hours. t/f ...... ANSWER ....... false

Smoke detection is most appropriate for which of the following occupancy types?
a.Business occupancies
b.Hotels
c.Medical clinic
d.All of the above ...... ANSWER ....... All of the above

A photoelectric smoke detector is best at detecting ? fires.
a.fast-developing
b.flaming
c.incipient
d.smoldering ...... ANSWER ....... smoldering

Graphic annunciators should be used in ? .
a.a large industrial complex
b.place of a fire alarm panel
c.small residential buildings
d.all of the above ...... ANSWER ....... a large industrial complex

In order to become listed, smoke detectors must respond to obscuration levels between ? .
a.0.5 and 3% per foot

, b.0.5 and 4% per foot
c.0 and 2% per foot
d.1 and 3% per foot ...... ANSWER ....... 0.5 and 4% per foot

Early warning of fire is best provided by using ? detectors.
a.heat
b.manual
c.smoke
d.waterflow ...... ANSWER ....... smoke

An average ambient sound pressure level of 60 dBA with a maximum sound pressure level of 63
dBA would require a signal sound pressure level of ? for public mode signaling.
a.65 dBA
b.68 dBA
c.70 dBA
d.75 dBA ...... ANSWER ....... 75 dBA

The prevention of smoke spread throughout a building is accomplished by ? .
a.door unlocking
b.duct smoke detectors
c.early warning
d.heat detectors ...... ANSWER ....... duct smoke detectors

A spot-type smoke detector covers a(n) ? area of protection.
a.circular
b.oval
c.rectangular
d.square ...... ANSWER ....... circular

Which of the following is a referenced code that is typically found in a fire alarm specification?
a.IBC
b.NFPA 10
c.UL268
d.UL864 ...... ANSWER ....... IBC

During a test of an interior fire alarm system, a worker notes several deficiencies that prevent
proper system operation. The most appropriate course of action is to ? .
a.forward this information to the proper inspector or department within the building or fire
service organization
b.inform the owner in writing what deficiencies exist
c.issue a citation to the owner
d.issue a violation to the owner ...... ANSWER ....... inform the owner in writing what
deficiencies exist

A circuit with a return loop and short circuit isolation between devices is a ? circuit.
a.Class A
b.Class B
c.Class C
$35.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
muriithi

Get to know the seller

Seller avatar
muriithi Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
6
Member since
2 year
Number of followers
2
Documents
647
Last sold
6 months ago
HERE YOU WILL FIND IT!!!

Think,Explore,Discover and meet a new difference....here I simply want to make what you want.... And Thank You Again For Chosing Me

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions