100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

CHAPTER 1-4 PUMPING AND AERIAL APPARATUS DRIVER/OPERATOR STUDY GUIDE|EXAM QUESTIONS AND VERIFIED ANSWERS|LATEST 2025/2026|GRADED A+

Rating
-
Sold
-
Pages
14
Grade
A+
Uploaded on
24-09-2025
Written in
2025/2026

CHAPTER 1-4 PUMPING AND AERIAL APPARATUS DRIVER/OPERATOR STUDY GUIDE|EXAM QUESTIONS AND VERIFIED ANSWERS|LATEST 2025/2026|GRADED A+

Institution
FIRE APPARATUS DRIVER/OPERATOR - PUMPER
Course
FIRE APPARATUS DRIVER/OPERATOR - PUMPER









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
FIRE APPARATUS DRIVER/OPERATOR - PUMPER
Course
FIRE APPARATUS DRIVER/OPERATOR - PUMPER

Document information

Uploaded on
September 24, 2025
Number of pages
14
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

APPARATUS DRIVER/OPERATOR STUDY
GUIDE|EXAM QUESTIONS AND VERIFIED


NFPA 1901 - ANSWER Standard for Automotive Fire Apparatus



NFPA 414 - ANSWER Standard for Aircraft Rescue and Fire-Fighting Vehicles



Foam Capability - ANSWER -Many FD including municipal, airport, wildland, and those
serving industrial facilities operate pumpers capable of discharging foam on Class A or Class
B fires.



-The foam proportioning systems commonly found on municipal fire pumpers are scaled
down versions of those used for industrial fire pumpers.



Foam Capability - ANSWER Both municipal and industrial foam pumpers may be
equipped with around the pump, direct injection, balanced pressure foam proportioning
systems



Compressed air foam system (CAFS) - ANSWER Generic term used to describe a high-
energy foam-generation system consisting of a water pump, a foam proportioning system,
and an air compressor (or other air source) that injects air into the foam solution before it
enters a hoseline.



Common Pumper Requirements and Equipment - ANSWER Requirements of Pumper
Design

-A minimum pump capacity of 750 gpm and a water tank with with a capacity of at least 300
gallons.

-Pump capacities larger than 750 gpm increase in increments of 250 gpm with most
municipal FD operating pumpers of 2,000 gpm or less.

, Common Pumper Requirements and Equipment - ANSWER Requirements of Pumper
Design

The apparatus must be equipped with intake and discharge pump connections, pump
controls and gauges, as well as a variety of hose sizes and types. These hoses include intake,
supply, and attack hose.



Rescue Pumper - ANSWER -Specially designed apparatus that combines the functions
of both a rescue vehicle and a fire department pumper.



-A rescue pumper carry medical, rescue, and extrication equipment.



Initial Attack Fire Apparatus - ANSWER Fire apparatus whose primary purpose is to
initiate a fire attack on structural and wildland fires and support associated fire department
actions. Also known as Midi-Pumper or Mini-Pumper.



Mini-Pumper - ANSWER Small fire apparatus mounted on a pickup-truck-sized chassis,
usually with a pump having a rated capacity less than 500 gpm



Midi-Pumper - ANSWER Apparatus sized between a mini pumper and a full size fire
department pumper, usually with a gross vehicle weight of 12,000 pounds or greater. Pump
not greater than 1,000 gpm



Mobile Water supply Apparatus - ANSWER -Are used to transport water to areas
where a water system is nonexistent or inadequate. Locally known as water tenders or
tankers.



-Mobile water supply apparatus, are equipped with a tank capacity of at least 1,000 gallons.



Mobile Water Supply Apparatus - ANSWER The capacity of mobile water supply
apparatus operating in a particular jurisdiction is based on a variety of factors including:

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Spotlight1 Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
16
Member since
1 year
Number of followers
1
Documents
4958
Last sold
1 week ago
A+ GRADED AND VERIFIED STUDY MATERIALS

Tested, UPDATED,Verified and 100% CORRECT Study Materials with 100% Guaranteed Success.

4.0

3 reviews

5
2
4
0
3
0
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions