100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)

Rating
-
Sold
2
Pages
37
Grade
A+
Uploaded on
22-09-2025
Written in
2025/2026

ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)

Institution
ABYC Systems Certification
Course
ABYC Systems Certification











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ABYC Systems Certification
Course
ABYC Systems Certification

Document information

Uploaded on
September 22, 2025
Number of pages
37
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY
WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)





Polyethylene - (ANSWER)What is the most often used materials for potable water systems?



1. Copper Alloys (incl. bronze, brass and nickel-copper)

2. AISI Type 300 series stainless steel

3. Glass-lined metal

4. FDA approved plastic

5. FDA approved rubber - (ANSWER)Name 5 materials allowable for contact use in potable water
systems:



Siphon Break - (ANSWER)What device can be used to separate potable water from other water systems?



Accumulator Tank, after pump/filter and before check-valve - (ANSWER)What is the device used to
maintain a stable pressure and minimize pump cycling, and where should it be located?



175% - (ANSWER)At what what percentage of nominal working pressure shall the relief valve be set?



No, typically these are too high (up to 400% of nominal pressure) - (ANSWER)Is a standard household
type relief valve acceptable for hot water tanks?



nominal working pressure, not to exceed 80 PSI - (ANSWER)For the pressure reducing valve and check
valve installed after a shore water connection, what is the maximum allowable pressure?



overboard - (ANSWER)Where shall the storage tank be vented?



3 PSI or mnfg's maximum, which ever is greater. - (ANSWER)What is the maximum allowable pressure to
which the storage tank and vent system be subjected?



-40 °F to +140 °F - (ANSWER)What temperate range is required for pumps to be able to tolerate
exposure?

,ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY
WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)






257 F - (ANSWER)When operating at an ambient temperature of 140 F, what is the max allowable
surface temperature of a pump?



True - (ANSWER)Potable water systems must be equipped with a drain. T or F?



False - (ANSWER)Storage tank inlet may also serve as the tank vent. T or F?



True - (ANSWER)Storage tank inlet caps must be retained to prevent loss. T or F?



True - (ANSWER)Storage tanks must be equipped with a vent. T or F?



True - (ANSWER)Storage tank vent may be used for filling purposes. T or F?



At least 1.5X the pressure exerted by the distance from the tank bottom to the deck fill plate or vent,
but not less than 3 PSI. - (ANSWER)What rate of static pressure must a storage tank withstand?



3 PSI - (ANSWER)What is the max pressure that a desalinator can impart to a storage tank?



True - (ANSWER)Each desalinator must be equipped with an automatic shutoff salinity detector. T or F?



"For Cold Water Use Only" - (ANSWER)What marking must be on pipe or tubes that are not capable of
handling hot water?



125 PSI, 300 PSI - (ANSWER)What is the test pressure for water heater tank 15 gal or less? over 15 gal
but under 120 gal?



175 PSI - (ANSWER)What is the max pressure relief valve setting for hot water tanks?

,ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY
WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)






210 F - (ANSWER)What is the max temperature relief setting for hot water tanks?



125 F - (ANSWER)What is the max allowable water output temperature for hot water system?



True - (ANSWER)All potable water system connections shall be positioned above the normal bilge water
accumulation level. T or F?



True - (ANSWER)Exposed metallic parts of a potable water system shall have provisions for electrical
bonding. T or F?



Improper venting - (ANSWER)For what reason might a holding tank collapse during pump-out?



Type I - (ANSWER)What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform
bacteria count <= 1,000 (per 100 ml) and no suspended solids?



Type II - (ANSWER)What type of MSD (Marine Sanitation Device) discharges effluent with fecal coliform
bacteria count <= 200 (per 100 ml) and <= 150 mg suspended solids per liter?



Type III - (ANSWER)What type of MSD (Marine Sanitation Device) is designed to hold sewage or any
waste derived from sewage?



Retention System - (ANSWER)What is the name given to the complete system including toilets, hoses,
pipes, holding tanks and fittings designed to receive, retain, vent and pump out sewage?



Treatment System - (ANSWER)What is the name of the system that includes all sanitation equipment
and fittings designed to receive, treat, vent and discharge sewage?

, ABYC Systems Certification EXAM WITH CORRECT ACTUAL QUESTIONS AND CORRECTLY
WELL DEFINED ANSWERS LATEST ALREADY GRADED A+ (2025/2026)





Siphon break - (ANSWER)What is another name for a vented loop that prevents back siphoning by
breaking suction yet allowing normal flow when pressurized?



5 - (ANSWER)When calculating holding tank size, how many flushes per day are included in the
calculation?



0.14 gallons - (ANSWER)What volume of human waste is used per flush when calculating holding tank
size?



True - (ANSWER)True or False: If a portable toilet is secured and fitted with a deck pump-out fitting and
vent it qualifies as a type III device.



Prevention of siphoning - (ANSWER)Why must careful consideration be given to the location and routing
of inlet and discharge lines for manual flush toilets when the "shut-off" merely bleeds air into the inlet
line?



Whenever components are installed below the max heeled water line - to prevent back flow into the
vessel or unintentional siphoning of untreated effluent overboard. - (ANSWER)When and why must
siphon breaks be installed in a sewage system?



True - (ANSWER)A seacock may be installed instead of a siphon break to prevent discharge and back
siphoning. T or F?



The handle must be lockable in the direction of the holding tank - (ANSWER)What special provision must
be included for a sewage y-valve when the discharge seacock is not lockable?



Air Gap, Vacuum Break, Double Check Valve, Dedicated Water Tank - (ANSWER)Name four ways to
separate a fresh water flushing system from potable water system.



1.5 inches - (ANSWER)What is the minimum hose ID for use on un-macerated sewage?
Free
Get access to the full document:
Download

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Testmister

Get to know the seller

Seller avatar
Testmister Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
1538
Member since
11 months
Number of followers
0
Documents
1082
Last sold
2 days ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions