PRACTICE EXAM QUESTIONS
WITH CORRECT DETAILED
ANSWERS | ALREADY GRADED
A+<RECENT VERSION>
1. The cof holder must keep the cof ___________ or readily available for
inspection - answer upon his or her person
2. Portable lpg containers that are more than ________ must not be stored,
handled, or used indoors. - answer 16.4 oz
3. Permits shall be readily available on the _________ for inspection by fire
department representatives. - answer premises
4. Hot work permits shall be available for inspection by any representative
for __________ after the work is complete. - answer 48 hours
5. For _____________, the owner of the hot work operation areas must be
notified in writing by the citywide permit holder at least 48 hours before
hot work is to be started. - answer citywide hot work operations
6. Pre-hot work checks must be conducted before hot work is authorized
and at least ___________. - answer once per day
,7. Fire watch will be provided for a minimum of _________ after work is
complete. - answer 30 minutes
8. Hot work areas must be kept ___________ feet away from any
combustible material. - answer 35
9. Paper, wood shavings, straw and fabric are examples of
______________. - answer combustible material
10.The entire work area should be checked after completion of hot work for
__________. - answer fires
11.A minimum ____________ rating fire extinguisher must be readily
accessible. - answer 2-a:20-b:c
12.The fire extinguisher must be accessible within __________ feet of hot
work location and fire guard. - answer 30
13.For torch-applied roof systems, a minimum ___________ rating fire
extinguisher must be readily accessible. - answer 3-a: 40-b:c
14.___________ protection systems shall not be shut off while hot work is
performed. - answer automatic sprinkler
15.Compressed gas containers must be replaced when ___________. -
answer they are empty
, 16.Empty containers must be handled in the same manner as ____________.
- answer full ones
17.A ___________ must not be rolled on its side or its rim. - answer
compressed gas container
18.The top of the fire extinguisher must not be more than ________ feet
above the floor, nor the bottom of the fire extinguisher be less than
_________ inches from the ground. - answer 5, 4
19.The cof holder should only consider extinguishing fires when they are
____________. - answer limited in size
20.Never approach a fire from a __________. - answer downwind
direction
21.Do not direct the chemical stream at the ________. - answer center of
the flame
22.For ________, the gas supply must be shut off first and then call 911. -
answer piped gas
23.When not possible to shut off gas supply, allow the flame to
___________ and call 911. - answer burn itself out
24.Class a extinguishers are for extinguishing ___________. - answer
ordinary combustibles
25.Class b extinguishers are for extinguishing ___________. - answer
flammable or combustible liquids