100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

TEXAS FIRE ALARM PRACTICE TEST 2025 BRAND NEW ACTUAL EXAM WITH 100- VERIFIED QUESTIONS AND CORRECT SOLUTIONS

Rating
-
Sold
-
Pages
34
Grade
A+
Uploaded on
12-09-2025
Written in
2025/2026

TEXAS FIRE ALARM PRACTICE TEST 2025 BRAND NEW ACTUAL EXAM WITH 100- VERIFIED QUESTIONS AND CORRECT SOLUTIONS

Institution
TEXAS FIRE ALARM
Course
TEXAS FIRE ALARM











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
TEXAS FIRE ALARM
Course
TEXAS FIRE ALARM

Document information

Uploaded on
September 12, 2025
Number of pages
34
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

P age | 1
| | | | |




TEXAS FIRE ALARM PRACTICE TEST 2025 BRAND
NEW ACTUAL EXAM WITH 100% VERIFIED
QUESTIONS AND CORRECT SOLUTIONS




All systems shall test free of
| | | | | | , except for applications in
| | | |


which
| | are approved. - correct answer - grounds,
| | | | | |


grounds
|

, P age | 2
| | | | |




So long as a single open, ground or short circuit conditioned do not
| | | | | | | | | | | |


affect the operation of equipment, what is not needed? - correct
| | | | | | | | | | |


answer - Monitoring for integrity. Such conditions must not prevent
| | | | | | | | | |


alarm, trouble or supervisory signals being sent.
| | | | | | |




If speakers are used to generate audible fire signals, What rule
| | | | | | | | | |


must apply? - correct answer - The speaker must be monitored
| | | | | | | | | | |


for integrity, and failure should result in a trouble signal.
| | | | | | | | | |




Where must a spot type heat and smoke sensors be located on
| | | | | | | | | | |


walls and ceilings? - correct answer - On the ceiling - not less than
| | | | | | | | | | | | | |


four inches from the sidewall
| | | | |




On the wall- between 4 inches and 12 inches from the ceiling
| | | | | | | | | | |




When more than one detector is used on a ceiling, what spacing
| | | | | | | | | | |


measurement shall be used? - correct answer - All points shall have
| | | | | | | | | | | |


a detector equal to 0.7 times the listed spacing.
| | | | | | | | |




When water flow occurs that is equal or greater than the flow of a
| | | | | | | | | | | | |


single sprinkler, how quickly shall the alarm signal initiate? - correct
| | | | | | | | | | |


answer - Within 90 seconds
| | | | |

, P age | 3
| | | | |




Can detectors be installed within an air duct system? Can they be
| | | | | | | | | | |


used as a substitute for open area protection? - correct answer -
| | | | | | | | | | | |


yes. AND no.
| | |




Detectors shall be for the purpose for which they are
| | | | | | | | |


being used. - correct answer - Listed (i.e. zone listed)
| | | | | | | | | |




Which signals must take priority over all other signals? - correct
| | | | | | | | | |


answer - Fire. Even if a non fire signal is generated first
| | | | | | | | | | | |




How many fire alarm boxes (pull stations) are required in systems
| | | | | | | | | |


employing automatic fire or water flow detectors? - correct answer
| | | | | | | | | |


- At least one, located where required by the authority having
| | | | | | | | | |


jurisdiction
|




Systems that require two automatic detectors to initiate the alarm
| | | | | | | | |


may only be used after which 3 conditions are filled? - correct
| | | | | | | | | | | |


answer - The systems are not prohibited by the authority having
| | | | | | | | | | |


jurisdiction
|

, P age | 4
| | | | |




-At least two automatic detectors are in each protected space
| | | | | | | | |




-The alarm verification feature is not used
| | | | | |




The number of water slow switches permitted to be connected to a
| | | | | | | | | | |


single initiating device shall not exceed
| | . - correct | | | | | |


answer - Five
| | |




What must be monitored for integrity? - correct answer - The
| | | | | | | | | |


installation wiring between the fire alarm control unit and the relay or
| | | | | | | | | | | |


other appliance (Horn, Strobe, etc)
| | | | |




Each elevator lobby, elevator hoist way and elevator machine
| | | | | | | |


room detector must be capable of what? - correct answer -
| | | | | | | | | | |


Initiating elevator recall when all other devices are in alarm
| | | | | | | | | |


condition
|




Must the alarm devices within the elevator hoist way be integrated
| | | | | | | | | |


with the fire alarm? - correct answer - Yes
| | | | | | | | |

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lectphilip West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
172
Member since
1 year
Number of followers
6
Documents
18799
Last sold
1 day ago
WELCOME TO LECTPHILIP, A PLACE WHERE WE UNLOCK YOUR ACADEMIC OPPORTUNITIES

On this page, you find all documents, package deals and flashcards offered by seller lectphilip

4.3

25 reviews

5
14
4
5
3
5
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions