100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

MAINE JOURNEYMAN PLUMBING EXAM WITH VERIFIED QUESTIONS AND ANSWERS|| ALREADY GRADED A+ || LATEST VERSION 2025 || GUARANTEED PASS

Rating
-
Sold
-
Pages
25
Grade
A+
Uploaded on
11-09-2025
Written in
2025/2026

MAINE JOURNEYMAN PLUMBING EXAM WITH VERIFIED QUESTIONS AND ANSWERS|| ALREADY GRADED A+ || LATEST VERSION 2025 || GUARANTEED PASS Joints at the roof around pipes shall be made watertight by the use of ___. - ANSWER-approved flashings Soil and drain pipes located above food handling establishments shall be subjected to a standing water test of not less than ___ feet. - ANSWER-10 ft Concealed slip joint connections require a/an ____ - ANSWER-12x12 access panel Where exposed or accessible a fixture tailpiece shall be permitted to be of seamless drawn brass not less than ___. - ANSWER-20 B&S gauge Lavatories shall have a waste outlet and fixture tailpiece not less than ___ inches in diameter. - ANSWER-1-1/4" No trap for any clothes washer standpipe shall be installed ___. - ANSWER below the floor The depth of the finished dam or threshold for any shower, measured from the top of the drain, shall not be less than _____ - ANSWER-2" When using asphalt-impregnated felt as the lining material for built on site shower receptors, it shall have not less than ___ with each succeeding layer hot mopped to that below. - ANSWER-3 layers, 15lb felt Water closet tank ballcocks shall be adjusted so the critical level is at least - ANSWER-1" above overflow Where static water pressure in the water supply piping is exceeding ___ psi an approved-type pressure regulator preceded by an adequate strainer shall be installed. - ANSWER-80 psi The terminal end of a pressure relief valve may not be - ANSWER-threaded "Cleanouts may be omitted on a horizontal drain line less than 5 feet except for _________________. - ANSWER-sinks Vent terminals in locations having minimum design temperatures below 0 F shall be not less than ___ inches. - ANSWER-2" In a combination waste and vent system serving a floor drain with a 2" tailpiece, the trap shall be - ANSWER-3" min. One trap may serve a set of not more than ___ single compartment sinks. - ANSWER-3 One trap may be installed for not more than 3 single compartment sinks located no more than_____ inches apart - ANSWER-30 A fixture tailpiece for a kitchen sink shall be a minimum of __________ in diameter. - ANSWER-1-1/2" A bathtub with slip joint connections shall be provided with - ANSWER-a 12x12 access panel Equipment and appliance located on roofs of buildings more than ___ shall have an inside means of access to the roof. - ANSWER-15 ft high Definition of a bathroom - ANSWER-A room with a shower or bathtub Building Drain - ANSWER-that part of the lowest horizontal piping of a drainage system which receives the discharge from soil, waste and other drainage pipes inside the walls of the building and conveys it to the building sewer beginning 0.6 meter outside the building wall. Vacuum - ANSWER-Any pressure less than that exerted by the atmosphere BUILDING SUPPLY - ANSWER-the pipe carrying potable water from the water meter or other source of water supply to a building or other point of use or distribution on the lot. Building supply shall also mean water service connection.

Show more Read less
Institution
MAINE JOURNEYMAN PLUMBING
Course
MAINE JOURNEYMAN PLUMBING

Content preview

MAINE JOURNEYMAN PLUMBING EXAM
WITH VERIFIED QUESTIONS AND ANSWERS||
ALREADY GRADED A+ || LATEST VERSION
2025 || GUARANTEED PASS




Joints at the roof around pipes shall be made watertight by the use of ___. -
ANSWER-approved flashings


Soil and drain pipes located above food handling establishments shall be
subjected to a standing water test of not less than ___ feet. - ANSWER-10 ft


Concealed slip joint connections require a/an ____ - ANSWER-12x12 access
panel


Where exposed or accessible a fixture tailpiece shall be permitted to be of
seamless drawn brass not less than ___. - ANSWER-20 B&S gauge


Lavatories shall have a waste outlet and fixture tailpiece not less than ___
inches in diameter. - ANSWER-1-1/4"


No trap for any clothes washer standpipe shall be installed ___. - ANSWER-
below the floor


The depth of the finished dam or threshold for any shower, measured from the
top of the drain, shall not be less than _____ - ANSWER-2"

,When using asphalt-impregnated felt as the lining material for built on site
shower receptors, it shall have not less than ___ with each succeeding layer hot-
mopped to that below. - ANSWER-3 layers, 15lb felt


Water closet tank ballcocks shall be adjusted so the critical level is at least -
ANSWER-1" above overflow


Where static water pressure in the water supply piping is exceeding ___ psi an
approved-type pressure regulator preceded by an adequate strainer shall be
installed. - ANSWER-80 psi


The terminal end of a pressure relief valve may not be - ANSWER-threaded


"Cleanouts may be omitted on a horizontal drain line less than 5 feet except for
_________________. - ANSWER-sinks


Vent terminals in locations having minimum design temperatures below 0 F
shall be not less than ___ inches. - ANSWER-2"


In a combination waste and vent system serving a floor drain with a 2" tailpiece,
the trap shall be - ANSWER-3" min.


One trap may serve a set of not more than ___ single compartment sinks. -
ANSWER-3


One trap may be installed for not more than 3 single compartment sinks located
no more than_____ inches apart - ANSWER-30


A fixture tailpiece for a kitchen sink shall be a minimum of __________ in
diameter. - ANSWER-1-1/2"

, A bathtub with slip joint connections shall be provided with - ANSWER-a
12x12 access panel


Equipment and appliance located on roofs of buildings more than ___ shall have
an inside means of access to the roof. - ANSWER-15 ft high


Definition of a bathroom - ANSWER-A room with a shower or bathtub


Building Drain - ANSWER-that part of the lowest horizontal piping of a
drainage system which receives the discharge from soil, waste and other
drainage pipes inside the walls of the building and conveys it to the building
sewer beginning 0.6 meter outside the building wall.


Vacuum - ANSWER-Any pressure less than that exerted by the atmosphere


BUILDING SUPPLY - ANSWER-the pipe carrying potable water from the
water meter or other source of water supply to a building or other point of use or
distribution on the lot. Building supply shall also mean water service
connection.


gray water - ANSWER-all of the wastewater that drains from washing
machines, sinks, dishwashers, tubs or showers and can be reused for non-
sanitary purposes


Burred ends of pipe and tubing shall be - ANSWER-reamed to the full bore of
the pipe or tube


Fixtures having concealed slip-joint connections shall be provided with -
ANSWER-a utility space or access panel


One factor for determining the size of a vent pipe is ___. - ANSWER-Its length

Written for

Institution
MAINE JOURNEYMAN PLUMBING
Course
MAINE JOURNEYMAN PLUMBING

Document information

Uploaded on
September 11, 2025
Number of pages
25
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$18.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
martinmwambingu54
4.0
(1)

Get to know the seller

Seller avatar
martinmwambingu54 Johns Hopkins University
View profile
Follow You need to be logged in order to follow users or courses
Sold
9
Member since
6 months
Number of followers
1
Documents
909
Last sold
1 week ago
A+ EXAM ARCHIVES YOUR BLUEPRINT FOR ACADEMIC SUCCESS!

Welcome to A+ EXAM ARCHIVES – Your New Frontier for Academic Success on Stuvia! We\'re pioneering a fresh approach to study resources. We\'re dedicated to bringing you meticulously engineered, verified study solutions designed to unlock your full potential and drive remarkable academic success. Our commitment is clear: to provide cutting-edge content that is not only exceptionally clear and accurate but also strategically optimized to streamline your learning process. Whether you\'re aiming to master complex concepts, prepare for upcoming challenges, or simply seeking intelligent, reliable study tools, our curated collection of next-gen notes, agile summaries, and comprehensive learning frameworks is built to give you a distinct advantage. We understand that today\'s students need more than just information – they need effective, innovative solutions. That\'s why every document we create is thoughtfully developed to meet your specific learning requirements, ensuring you have the powerful tools to navigate your academic journey with absolute confidence. Join us at the forefront of smarter studying. Explore our store today and be among the first to experience a new level of academic support. Activate your A+ potential now!

Read more Read less
4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions