Q1: What is the difference between compaction and density?
A: Compaction is the process used to achieve density, the product. ■
Q2: What is the governing order of documents in FDOT specifications?
A: 1) Special Provisions, 2) Technical Special Provisions, 3) Plans (including revisions), 4) Design
Standards, 5) Developmental Specifications, 6) Supplemental Specifications, 7) Standard Specifications. ■
Q3: What is the typical Proctor test used for base, subgrade, and MSE wall backfill materials?
A: Modified Proctor Test. ■
Q4: What is the typical Proctor test used for embankment and structure backfill materials?
A: Standard Proctor Test. ■
Q5: What is the required maximum density for the Modified Proctor test?
A: 98%. ■
grade-A
official revision
STUDY GUIDE - FDOT Earthwork 2 study guide year 2025-2026 - Page 3
, FDOT Earthwork 2
Q6: What is the required maximum density for the Standard Proctor test?
A: 100%. ■
Q7: What does LBR stand for?
A: Limerock Bearing Ratio. ■
Q8: What is the LBR test used for?
A: It is a strength test of material based on standardized 800 psi. ■
Q9: What is the maximum particle size permitted in the top 12 inches of an embankment?
A: 3 inches. ■
Q10: What is the maximum particle size permitted below 24 inches in an embankment?
A: 6 inches. ■