Michigan Manicurist Practice Test comprehensive questions and verified accurate solution
(detailed & elaborated) 2025 TEST!!
A __________ receptacle may be included on the small appliance branch circuit? - ✔✔ electric
clock- gas range, 210.52(B)(2)(exp 112)
A 1" conduit contains three 3-wire circuits or a phase system. All conductors are #10TW. Each circuit
consists of two-phase conductors and one grounded conductor and one equipment grounding
conductor. The maximum ampacity of each phase conductor is __________. - ✔✔ 24A,
310.15(B)(16)
A 15 or 20 amp receptacle shall be located with-in____________feet of a roof top air conditioner? -
✔✔ 25', 210.63
A 208volt, 3 phase heater draws 3,598 watts. How many amperes does the heater draw? - ✔✔ 10A,
P=E x 1.73/I. I=3598/359.84
A AC general use snap switch used to control a motor load shall not exceed __________% of the
ampere rating of the switch at its rated voltage. - ✔✔ 80, 404.14(A)(3)
A dishwasher does not need a GFCI when? - ✔✔ Always needs GFCI protection. 210.8(D)
A feeder in a single-family dwelling supplies a load pf 75 amps of electrical space heating and 25
amps of air conditioning(cooling). The required capacity of the feeder is ____________ amperes? -
✔✔ 75, 220.82(B)
A general-purpose receptacle shall not be installed on the_____________. - ✔✔ Fence - Directly
south of the pool. 680.22(A)(1)
A GFCI protected___________receptacle for the pump motor maybe installed on the south side of
the dwelling unit dedicated grounding type. - ✔✔ dedicated receptacle, 680.22(A)(2)
A high impedance grounded system is limited to systems operating as ____________ volts or above?
- ✔✔ 480V, 250.36
, A junction box for the 120 volt wet-niche fixture shall be at least_________inches above the
ground? - ✔✔ 4", 680.24(A)(2)(a)
A kiln rated 4750 watts, 208volt 3 phase draws __________ amps. - ✔✔ 13.2A. I=P/E x 1.73
A laundry branch circuit shall be rated at ______________amps. - ✔✔ 20, 210.11(C)(2)
A light fixture that weighs more than ________ pounds shall be supported independently of the
fixture junction box. - ✔✔ 50#, 314.27(A)(2)
A metal fence installed with-in_________feet of the pool shall be bonded. - ✔✔ 5', 680.26(B)(7)
A metal light pole must have a accessible hand hole not less than _______________. - ✔✔ 2" x 4",
410.30(B)(1)
A receptacle for laundry equipment shall be located within ________ feet of the intended location. -
✔✔ 6', 210.50(C)
A screw connecting the natural bar or a grounded system to the service equipment enclosure is call
the ____________? - ✔✔ main bonding jumper, 250.20(B)-250.28(B)
A service disconnect shall be rated not less than ___________ amps for one-family dwelling units. -
✔✔ 100A, 230.79(C)
A single non-motor operated appliance of 13.4 amps shall have overcurrent protection not to exceed
_________ percent of appliance rating. - ✔✔ 150, 472.11(E)(3)
An AC system of 50 to 1000 volts shall be grounded if maximum voltage to ground does not exceed
______________ volts. - ✔✔ 150, 250.20(B)(1)
An apprentice must register with the State of Michigan within __________ days of initial
employment. - ✔✔ 30, 339.5717(1)
(detailed & elaborated) 2025 TEST!!
A __________ receptacle may be included on the small appliance branch circuit? - ✔✔ electric
clock- gas range, 210.52(B)(2)(exp 112)
A 1" conduit contains three 3-wire circuits or a phase system. All conductors are #10TW. Each circuit
consists of two-phase conductors and one grounded conductor and one equipment grounding
conductor. The maximum ampacity of each phase conductor is __________. - ✔✔ 24A,
310.15(B)(16)
A 15 or 20 amp receptacle shall be located with-in____________feet of a roof top air conditioner? -
✔✔ 25', 210.63
A 208volt, 3 phase heater draws 3,598 watts. How many amperes does the heater draw? - ✔✔ 10A,
P=E x 1.73/I. I=3598/359.84
A AC general use snap switch used to control a motor load shall not exceed __________% of the
ampere rating of the switch at its rated voltage. - ✔✔ 80, 404.14(A)(3)
A dishwasher does not need a GFCI when? - ✔✔ Always needs GFCI protection. 210.8(D)
A feeder in a single-family dwelling supplies a load pf 75 amps of electrical space heating and 25
amps of air conditioning(cooling). The required capacity of the feeder is ____________ amperes? -
✔✔ 75, 220.82(B)
A general-purpose receptacle shall not be installed on the_____________. - ✔✔ Fence - Directly
south of the pool. 680.22(A)(1)
A GFCI protected___________receptacle for the pump motor maybe installed on the south side of
the dwelling unit dedicated grounding type. - ✔✔ dedicated receptacle, 680.22(A)(2)
A high impedance grounded system is limited to systems operating as ____________ volts or above?
- ✔✔ 480V, 250.36
, A junction box for the 120 volt wet-niche fixture shall be at least_________inches above the
ground? - ✔✔ 4", 680.24(A)(2)(a)
A kiln rated 4750 watts, 208volt 3 phase draws __________ amps. - ✔✔ 13.2A. I=P/E x 1.73
A laundry branch circuit shall be rated at ______________amps. - ✔✔ 20, 210.11(C)(2)
A light fixture that weighs more than ________ pounds shall be supported independently of the
fixture junction box. - ✔✔ 50#, 314.27(A)(2)
A metal fence installed with-in_________feet of the pool shall be bonded. - ✔✔ 5', 680.26(B)(7)
A metal light pole must have a accessible hand hole not less than _______________. - ✔✔ 2" x 4",
410.30(B)(1)
A receptacle for laundry equipment shall be located within ________ feet of the intended location. -
✔✔ 6', 210.50(C)
A screw connecting the natural bar or a grounded system to the service equipment enclosure is call
the ____________? - ✔✔ main bonding jumper, 250.20(B)-250.28(B)
A service disconnect shall be rated not less than ___________ amps for one-family dwelling units. -
✔✔ 100A, 230.79(C)
A single non-motor operated appliance of 13.4 amps shall have overcurrent protection not to exceed
_________ percent of appliance rating. - ✔✔ 150, 472.11(E)(3)
An AC system of 50 to 1000 volts shall be grounded if maximum voltage to ground does not exceed
______________ volts. - ✔✔ 150, 250.20(B)(1)
An apprentice must register with the State of Michigan within __________ days of initial
employment. - ✔✔ 30, 339.5717(1)