100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA SECTION 608 TYPE I, TYPE II , TYPE III

Rating
-
Sold
-
Pages
52
Grade
A+
Uploaded on
10-08-2025
Written in
2025/2026

EPA SECTION 608 TYPE I, TYPE II , TYPE III

Institution
EPA SECTION 608 TYPE I, TYPE II , TYPE III
Course
EPA SECTION 608 TYPE I, TYPE II , TYPE III











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA SECTION 608 TYPE I, TYPE II , TYPE III
Course
EPA SECTION 608 TYPE I, TYPE II , TYPE III

Document information

Uploaded on
August 10, 2025
Number of pages
52
Written in
2025/2026
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EPA SECTION 608 TYPE I, TYPE II , TYPE III
Study online at https://quizlet.com/_f2h0x8

1. What is typically used on small appliances as a service a. A straight piece of tub-
aperture or other device for adding or removing re- ing that is entered using a
frigerant? piercing access tube.
a. A straight piece of tubing that is entered using a
piercing access tube.
b. A line located 15 inches below the compressor.
c. A valve installed at the factory which has a ¼ inch
diameter and machine threads.
d. A service aperture is not present because small
appliances are exempt from this requirement.

2. What type of appliances are technicians certified to a. Appliances containing
service after passing the type 1 examination? 5 pounds or less of re-
a. Appliances containing 5 pounds or less of refriger- frigerant that have been
ant that have been hermetically sealed and charged hermetically sealed and
at the factory. charged at the factory.
b. Split systems containing 5 pounds or less of refrig-
erant that have been hermetically sealed and charged
at the factory.
c. Appliances containing 5 pounds or less of refrig-
erant that have an open drive compressor and have
been charged at the factory.
d. Motor vehicle air conditioning equipment.

3. What type of certification is required for persons re- c. Type I technician.
covering CFC's, HCFCs, or HFCs during maintenance,
service, or repair of small appliances.
a. Type II technician.
b. Type III technician.
c. Type I technician.
d. Technician who has passed the core exam.



, EPA SECTION 608 TYPE I, TYPE II , TYPE III
Study online at https://quizlet.com/_f2h0x8

4. EPA Section 608 rules require capture of 80% of the c. either a passive or an
HCFC and HFCs from a small appliance sealed systems active recovery process.
with a non-operating compressor if technicians are
using;
a. a system-dependent (passive) process.
b. a self-contained (active) process.
c. either a passive or an active recovery process.
d. neither recovery process.

5. Which of the following does NOT meet the criteria for a. A MVAC-like system that
Type 1 appliance certification? holds three pounds of
a. A MVAC-like system that holds three pounds of R-12.
R-12.
b. a water cooler that holds 13 ounces of R-22
c. a food freezer that holds 22 ounces of R-134a
d. A dehumidifier that holds seven ounces of R-410A

6. What of the following are included in EPA's definition a. Products fully manufac-
of "small appliance?" tured, charged, and her-
a. Products fully manufactured, charged, and hermet- metically sealed in a facto-
ically sealed in a factory. ry.
b. Products having 15 pounds or less of refrigerant.
c. Products with compressors under ½ horsepower.
d. Fully charged components ready for installation in
a split system.

7. Which of the following is an approved substitute re- a. R-600a
frigerant for new household refrigerators, freezers,
and combination refrigeration/freezers?
a. R-600a
b. R-1234yf




, EPA SECTION 608 TYPE I, TYPE II , TYPE III
Study online at https://quizlet.com/_f2h0x8

c. R-1234zd
d. R-170

8. Which hydrocarbon refrigerant is approved for retrofit d. Hydrocarbons are not
into existing household refrigerators? approved for retrofit ap-
a. HC R-600a 2 ounces or less plications
b. Blended HC R-441A
c. HC R-290 1 lb. or less
d. Hydrocarbons are not approved for retrofit applica-
tions

9. Recovery devices for use with small appliances con- a. Recovering 90% of the
taining CFCs, HCFCs, and HFCs must meet which of the refrigerant when the com-
following requirements? pressor is operating or
a. Recovering 90% of the refrigerant when the com- achieving a 4-inch vacu-
pressor is operating or achieving a 4-inch vacuum um under the conditions
under the conditions of AHRI 740. of AHRI 740.
b. Recovering 80% of the refrigerant when the com-
pressor is operating.
c. Recovering 95% of the refrigerant when the com-
pressor is operating or achieving a 10-inch vacuum
under the conditions of AHRI 740.
d. Recovering 75% of the refrigerant when the com-
pressor is operating.

10. What is the approximate pressure of a storage cylin- b. 87 psig
der of recovered R-134a that does not contain any
non-condensable impurities and is stored in a room
where the temperature is 80°F?
a. 37 psig
b. 87 psig




, EPA SECTION 608 TYPE I, TYPE II , TYPE III
Study online at https://quizlet.com/_f2h0x8

c. 157 psig
d. 207 psig

11. Before beginning a refrigerant recovery procedure, it b. know the type of refrig-
is ALWAYS necessary to; erant that is in the system.
a. allow the appliance to stabilize at room tempera-
ture.
b. know the type of refrigerant that is in the system.
c. remove the appliance to an outdoor location.
d. disconnect the appliance from its power source.

12. A passive system-dependent recovery process for c. captures refrigerant in a
small appliances; non-pressurized contain-
a. still uses a pump to recover refrigerant. er.
b. must use a pressure relief device when recovering
refrigerant.
c. captures refrigerant in a non-pressurized container.
d. can only be performed on a system with an operat-
ing compressor.

13. For which of the following refrigeration systems/appli- d. A domestic refrigerator
ances would it be permissible to use a passive recov-
ery device for recovery of CFCs, HCFCs, and HFCs?
a. A centrifugal air conditioner
b. A reciprocating liquid chiller
c. A single compressor large commercial walk-in freez-
er
d. A domestic refrigerator

14. What is the maximum normal charge of HCFC or HFC c. 15 pounds
refrigerant in an appliance that is allowed to use sys-
tem dependent recovery equipment?
a. 5 pounds

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PROFLEAK NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
1089
Member since
3 year
Number of followers
701
Documents
2637
Last sold
3 days ago
Stuvia verified shop 2024

EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF A Am an expert on major courses especially; psychology,Nursing, Human resource Management and Mathemtics Assisting students with quality work is my first priority. I ensure scholarly standards in my documents and that's why i'm one of the BEST GOLD RATED TUTORS in STUVIA. I assure a GOOD GRADE if you will use my work.

Read more Read less
4.4

2031 reviews

5
1313
4
410
3
243
2
25
1
40

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions