All recovery devices manufactured BEFORE November 15, 1993 for use with small
appliances must meet which of the following requirements - Answer-Capable of
recovering 80% of the refrigerant whether or not the compressor is operating or
achieving a 4 inch vacuum under conditions of ARI 740-1993
All appliances must be equipped with the service aperture or other device which is used
when adding or removing refrigerant from the appliance. For small appliances this
service port typically is - Answer-A straight piece of tubing that is entered using a
piercing access valve
Any person who opens an appliance for maintenance service or repair must have at
least one self-contained recovery machine available at their place of business. The
exceptions to this rule or persons working on - Answer-Small appliances
The sale of CFC and HCFC refrigerant is - Answer-Restricted to technicians who are
EPA certified in refrigerant recovery
EPA rules require capture of 80% of the refrigerant from a small appliance sealed
systems with a non-operating compressor if technicians are using - Answer-A system
dependent (passive) process
When using nitrogen in repairing a sealed refrigeration system with a nitrogen tank you
should always be equipped with a - Answer-Regulator
If a large leak of refrigerant occurs such as from a field cylinder in an enclosed area
what action should be taken when no self-contained breathing apparatus is available -
Answer-Vacate and ventilate the spill area
Portable refillable tanks or containers used to ship CFC or HCFC refrigerant obtained
with recovery equipment must meet what standards - Answer-Department of
transportation DOT
When filling a graduated charging cylinder refrigerant that is vented off the top of the
cylinder - Answer-Must be recovered
, When filling a charging cylinder refrigerant that is vented off the top of the cylinder -
Answer-Must be recovered regardless of the refrigerant
Which of the following refrigerants is most commonly used as a replacement for R-12 in
new household refrigerators - Answer-134a
When a household refrigerator compressor does not run it is recommended that low and
high side access valves be installed when recovering refrigerant from the system
because - Answer-It can enhance the speed of recovery
It may be necessary to achieve required recovery efficiency
Both A and B
When installing any type of access fitting onto a sealed system - Answer-The fitting
should be leak tested before proceeding with recovery
Which of the following is not a method or device presently used for monitoring the 80%
fill level in a recovery tank - Answer-Sight glass
A standard vacuum pump designed specifically for evacuation and hydration can -
Answer-Never be used as a recovery device in combination with a pressurize container
Before shipping any used refrigerant in a cylinder is necessary to - Answer-Properly
label the refrigerant container
Properly complete shipping paperwork
Check that the refrigerant container meets department of transportation standards
All of the above
Which refrigerants can be mixed - Answer-None of the above
When used solderless type piercing valves should not remain installed On refrigeration
systems after completion of repairs because - Answer-They tend to leak overtime
A storage cylinder of recovered R-12 at normal room temperature (about 75°F) in the
absence of non-combustible's will be pressurized to - Answer-75 psig
Portable refillable tanks or containers used to ship CFC or HCFC refrigerants obtained
with recovery equipment must meet what standards - Answer-Department of
transportation DOT
The system dependent (passive) recovery process - Answer-Recovers refrigerant in a
non-pressurized container
It is generally recommended that piercing type valves be used on which of the following
tubing materials - Answer-Copper
Aluminum