Residential owners are responsible = - Answers 570
Residential cabling responsibilities have shifted from the access provider = - Answers To the end users
the owners of homes
How many grades of residential premise for telecommunications cable = - Answers Two
What does grade 1 residential cabling consist of ? - Answers Grade 1 - Provide a generic cabling system
that meets the minimum requirements for telecommunications service, install one cat5e balanced
twisted pair and 1 75 ohm coax, cat6 is recommended
What is grade 2 residential cabling consist of ? - Answers Grade 2 residential cabling provides a
minimum of two 4-pair balanced twisted pair cables and associated connectors that meet of exceed the
requirements for cat5e and two 75 ohm series 6 coaxial cables, additionally two strand fiber cabling may
be installed
Each living area should be cabled with at least = - Answers One telecommunications outlet
All cabling shall be home run directly form individual telecommunications outlets to = - Answers DD
distribution device
Demarcation point DP - Answers Exterior building wall
Recommended backbone cables include = - Answers EXCETP wirelss
Star topology should be implemented for = - Answers - Balanced twisted pair
- Fiber can be star or ring topology
ADO Balanced twisted pair should be two 4-pair cables = - Answers Per living unit to provide for
- telephone lines
- data
- security
Electrical ground should be = - Answers 5 ft from the DD distribution device
The DD should have = - Answers 20 T0 50 percent growth
A dedicated 1-ampere [A], 120 volt [V] alternating current AC nominal, non-switchable duplex electrical
outlet must be provided with = - Answers 5ft of the DD
Recommended outlet cable includes = - Answers - 4-pair 100 ohm balanced twisted pair cat5e tho cat6
is recommended