Which of the following do the source and the medium determine? a. duty factor b. frequency c. propagation speed d. axial resolution - ANSWERSd. Axial resolution is affected by all of the following EXCEPT a. frequency b. damping c. spatial pulse length d. focusing - ANSWERSd. Damping in a transducer a. reduces the number of cycles in a pulse and increases the quality factor b. increases the number of cycles in a pulse and increases penetration c. causes poor axial and lateral resolution d. reduces the duty factor and increases the range of transmitted frequencies - ANSWERSd. Far zone beam divergence can be reduced on a single-element transducer by using a. a transducer with a smaller element diameter b. a higher frequency transducer c. a lower frequency transducer or a smaller element diameter d. adjustable focusing - ANSWERSb. The area between the face of an unfocused single-element transducer and the point where the beam starts to diverge is the a. Fraunhofer zone b. refraction zone c. focal zone d. near zone - ANSWERSd. Assuming a fixed frequency, what happens if the diameter of an unfocused transducer is increased? a. the far zone divergence increases b. the penetration decreases c. the length of the near zone increases d. the length of the near zone decreases - ANSWERSc. Which of the following does NOT affect lateral resolution? a. focusing b. element diameter c. frequency d. bandwidth - ANSWERSd. Higher frequency transducers provide a. improved lateral resolution b. smaller Doppler shifts c. improved axial resolution and reduced attenuation d. increased penetration - ANSWERSa. Ultrasound waves that are traveling through a medium consist of a. electromagnetic and radio frequencies b. compressions and refractions c. electromagnetic and ionizing frequencies d. compressions and rarefactions - ANSWERSd. What is the difference between audible sound and ultrasound? a. audible sound waves can travel through a vacuum b. audible sound has a higher frequency c. ultrasound has a higher frequency d. ultrasound waves are ionizing - ANSWERSc. A decrease in the thickness of a piezoelectric element will result in a. a greater pulse duration b. an increase in the propagation speed c. a decrease in the quality factor if the bandwidth decreases d. an increase in the frequency of the transducer - ANSWERSd. The resonant frequency of a pulsed-wave ultrasound transducer is dependent on a. damping b. the backing material c. the thickness of the piezoelectric element and the speed of sound through the piezoelectric element d. the amplitude of the voltage applied to the piezoelectric element - ANSWERSc. The image is brighter at the level of the focal zone. Which of the following controls is best to correct this? a. overall gain b. TGC c. acoustic power d. PRF - ANSWERSb. If the frequency is doubled, a. the duty factor will increase b. the period will double c. the wavelength will double d. the wavelength will be one-half - ANSWERSd. The typical range of pulse repetition frequencies in a pulse-echo ultrasound system is a. 2,000 Hz to 20,000 Hz b. 20 MHz to 200 MHz c. 20,000 Hz to 200,000 Hz d. 1,000 Hz to 2,000 Hz - ANSWERSd. If the number of cycles in a pulse is reduced, a. the pulse repetition frequency is automatically reduced b. the spatial pulse length increases c. the pulse duration is reduced which results in a lower duty factor d. the bandwidth is decreased and the quality factor is increased - ANSWERSc. The minimum reflector separation required to produce separate echoes is a. the spatial resolution of the ultrasound system b. the temporal resolution c. the attenuation coefficient d. the total attentuation - ANSWERSa. As the frequency of sound increases, a. the amount of scatter is increased b. the attenuation decreases c. the amount of scatter decreases d. the penetration increases - ANSWERSa. Which of the following transducers provides the maximum penetration? a. 10.0 MHz b. 7.5 MHz c. 2.25 MHz d. 3.5 MHz - ANSWERSc. The average attenuation of ultrasound energy in the patient is approximately a. 2.0 dB per cm per MHz b. 10.0 dB per cm per MHz c. 5. dB per cm per MHz d. 0.7 dB per cm per MHz - ANSWERSd. If sound from a 3 MHz transducer has 3 dB of attenuation after traveling through 2 cm of tissue, what is the amount of attenuation of sound from a 5 MHz transducer after traveling through 1 cm of the same tissue? a. 5 dB b. 1 dB c. 2 dB d. 2.5 dB - ANSWERSd. The half-value layer or the half-intensity-depth a. is the depth where the intensity is 50% of the originally transmitted intensity b. increases as the frequency of the transmitter increases c. is the range of frequencies contained in an ultrasound pulse d. is the attenuation coefficient in tissue - ANSWERSa. The speed of ultrasound in soft tissue is closest to a. 1.54 mm/sec b. 1540 km/sec c. 1540 mm/sec d. 1540 m/s - ANSWERSd. Ultrasound energy is traveling through the same medium. If the frequency is doubled, the propagation speed is a. quartered b. doubled c. halved d. unchanged - ANSWERSd.

Show more Read less
Institution
SPI Practice
Course
SPI Practice










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
SPI Practice
Course
SPI Practice

Document information

Uploaded on
July 14, 2025
Number of pages
29
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • spi practice test stuvia

Content preview

SPI Practice Test Questions with
Accurate Answers
Which of the following do the source and the medium determine?


a. duty factor
b. frequency
c. propagation speed
d. axial resolution - ANSWERSd.

Axial resolution is affected by all of the following EXCEPT

a. frequency
b. damping
c. spatial pulse length
d. focusing - ANSWERSd.

Damping in a transducer

a. reduces the number of cycles in a pulse and increases the quality factor
b. increases the number of cycles in a pulse and increases penetration
c. causes poor axial and lateral resolution
d. reduces the duty factor and increases the range of transmitted frequencies -
ANSWERSd.

Far zone beam divergence can be reduced on a single-element transducer by using

a. a transducer with a smaller element diameter
b. a higher frequency transducer
c. a lower frequency transducer or a smaller element diameter
d. adjustable focusing - ANSWERSb.

The area between the face of an unfocused single-element transducer and the point
where the beam starts to diverge is the

a. Fraunhofer zone
b. refraction zone
c. focal zone
d. near zone - ANSWERSd.

,Assuming a fixed frequency, what happens if the diameter of an unfocused transducer
is increased?

a. the far zone divergence increases
b. the penetration decreases
c. the length of the near zone increases
d. the length of the near zone decreases - ANSWERSc.

Which of the following does NOT affect lateral resolution?

a. focusing
b. element diameter
c. frequency
d. bandwidth - ANSWERSd.

Higher frequency transducers provide

a. improved lateral resolution
b. smaller Doppler shifts
c. improved axial resolution and reduced attenuation
d. increased penetration - ANSWERSa.

Ultrasound waves that are traveling through a medium consist of

a. electromagnetic and radio frequencies
b. compressions and refractions
c. electromagnetic and ionizing frequencies
d. compressions and rarefactions - ANSWERSd.

What is the difference between audible sound and ultrasound?

a. audible sound waves can travel through a vacuum
b. audible sound has a higher frequency
c. ultrasound has a higher frequency
d. ultrasound waves are ionizing - ANSWERSc.

A decrease in the thickness of a piezoelectric element will result in

a. a greater pulse duration
b. an increase in the propagation speed
c. a decrease in the quality factor if the bandwidth decreases
d. an increase in the frequency of the transducer - ANSWERSd.

The resonant frequency of a pulsed-wave ultrasound transducer is dependent on

, a. damping
b. the backing material
c. the thickness of the piezoelectric element and the speed of sound through the
piezoelectric element
d. the amplitude of the voltage applied to the piezoelectric element - ANSWERSc.

The image is brighter at the level of the focal zone. Which of the following controls is
best to correct this?

a. overall gain
b. TGC
c. acoustic power
d. PRF - ANSWERSb.

If the frequency is doubled,

a. the duty factor will increase
b. the period will double
c. the wavelength will double
d. the wavelength will be one-half - ANSWERSd.

The typical range of pulse repetition frequencies in a pulse-echo ultrasound system is

a. 2,000 Hz to 20,000 Hz
b. 20 MHz to 200 MHz
c. 20,000 Hz to 200,000 Hz
d. 1,000 Hz to 2,000 Hz - ANSWERSd.

If the number of cycles in a pulse is reduced,

a. the pulse repetition frequency is automatically reduced
b. the spatial pulse length increases
c. the pulse duration is reduced which results in a lower duty factor
d. the bandwidth is decreased and the quality factor is increased - ANSWERSc.

The minimum reflector separation required to produce separate echoes is

a. the spatial resolution of the ultrasound system
b. the temporal resolution
c. the attenuation coefficient
d. the total attentuation - ANSWERSa.

As the frequency of sound increases,

a. the amount of scatter is increased
b. the attenuation decreases

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Bestgrades2 West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
23
Member since
1 year
Number of followers
0
Documents
3985
Last sold
2 months ago

4.0

3 reviews

5
1
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions