4 Stages of combustion correct answers 1. Moisture evaporation 2. Release of combustible gases 3. Ignition of combustible gas 4. Char burning The total energy produced by burning one pound of wood is approximately____________ correct answers 8,600 BTUs Catalytic converters can lower the ignition temperature of wood smoke to approximately correct answers 500 degrees The proper UL Standard for chimneys used to vent wood stoves is correct answers UL103HT UL103HT correct answers These requirements cover factory-built chimneys intended for venting gas, liquid, and solid-fuel fired residential-type appliances and building heating appliances According to NFPA 211, the maximum horizontal run of a wood stove connector is limited to ______________ percent of the vertical portion of the chimney above the connector. correct answers 50% According to NFPA 211, a manual damper installed in a wood stove connector pipe cannot block more than ___________ percent of the connector when fully closed. correct answers 80% According to NFPA 211, the maximum permitted chimney flue area is ______ times the appliance flue collar area for exterior chimneys and ____ times the appliance flue collar area for interior chimneys. correct answers 2 and 3 The maximum chimney offset angle permitted in the United States is __________ degrees (from vertical). correct answers 30 degrees According to NFPA 211 and the IRC, a 3.5" brick wall with a 1" ventilated air space provides a __________ percent clearance reduction correct answers 66% According to NFPA 211 and the IRC, a 3.5" brick wall without ventilated air space provides a __________ percent clearance reduction. correct answers 33% According to NFPA 211 and the IRC, a 24 gauge sheet metal panel with a 1" ventilated air space provides a __________ percent clearance reduction when used as a ceiling protector. correct answers 50% The standard clearance to combustibles for an unlisted woodstove is ___________ inches. correct answers 36" What is UL 1618?

Show more Read less
Institution
NFI
Course
NFI








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NFI
Course
NFI

Document information

Uploaded on
July 7, 2025
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

NFI Core Review Class || QUESTIONS & ANSWERS
RATED 100% CORRECT!!
4 Stages of combustion correct answers 1. Moisture evaporation
2. Release of combustible gases
3. Ignition of combustible gas
4. Char burning

The total energy produced by burning one pound of wood is approximately____________
correct answers 8,600 BTUs

Catalytic converters can lower the ignition temperature of wood smoke to approximately
correct answers 500 degrees

The proper UL Standard for chimneys used to vent wood stoves is correct answers UL103HT

UL103HT correct answers These requirements cover factory-built chimneys intended for
venting gas, liquid, and solid-fuel fired residential-type appliances and building heating
appliances

According to NFPA 211, the maximum horizontal run of a wood stove connector is limited to
______________ percent of the vertical portion of the chimney above the connector. correct
answers 50%

According to NFPA 211, a manual damper installed in a wood stove connector pipe cannot
block more than ___________ percent of the connector when fully closed. correct answers
80%

According to NFPA 211, the maximum permitted chimney flue area is ______ times the
appliance flue collar area for exterior chimneys and ____ times the appliance flue collar area
for interior chimneys. correct answers 2 and 3

The maximum chimney offset angle permitted in the United States is __________ degrees
(from vertical). correct answers 30 degrees

According to NFPA 211 and the IRC, a 3.5" brick wall with a 1" ventilated air space provides
a __________ percent clearance reduction correct answers 66%

According to NFPA 211 and the IRC, a 3.5" brick wall without ventilated air space provides
a __________ percent clearance reduction. correct answers 33%

According to NFPA 211 and the IRC, a 24 gauge sheet metal panel with a 1" ventilated air
space provides a __________ percent clearance reduction when used as a ceiling protector.
correct answers 50%

The standard clearance to combustibles for an unlisted woodstove is ___________ inches.
correct answers 36"

What is UL 1618?

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ProPerfomer (self)
View profile
Follow You need to be logged in order to follow users or courses
Sold
431
Member since
2 year
Number of followers
322
Documents
8502
Last sold
1 week ago
Global Scholars’ Resource Hub

Welcome to your ultimate exam success hub! We provide top-quality, up-to-date, and approved exam materials—study guides, practice tests, and notes for a variety of subjects. Whether you’re preparing for school, college, or professional exams, our resources are designed to help you study smarter and score higher. Thousands have passed with our materials—now it’s your turn!Need more resources or something specific? Contact me anytime, and I’ll be happy to help you find exactly what you need. Your success is our mission!" ✅ Covers multiple subjects and exam types ✅ Includes real practice questions, answers, and study tips ✅ Ideal for students, test takers, and last-minute review Your Exam Success Starts Here – Grab Your Bundle Before It’s Gone!

Read more Read less
3.9

83 reviews

5
36
4
25
3
9
2
1
1
12

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions