NICET - Fire Alarm Systems (Level 2) UPDATED Exam Questions and CORRECT Answers 2000 cfm - CORRECT ANSWER - The International Mechanical Code requires a duct smoke detector in the return for units over ________ cfm 15000 - CORRECT ANSWER - The International Mechanical Code (IMC) requires a duct smoke detector in the supply for units over __________ cfm 4 hours - CORRECT ANSWER - Digital alarm communicator transmitters (DACT) which use call forwarding to the DACR shall be tested with what frequency

Show more Read less
Institution
Nicet
Course
Nicet











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Nicet
Course
Nicet

Document information

Uploaded on
June 13, 2025
Number of pages
59
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NICET - Fire Alarm Systems (Level 2)
UPDATED Exam Questions and
CORRECT Answers
2000 cfm - CORRECT ANSWER - The International Mechanical Code requires a duct
smoke detector in the return for units over ________ cfm


15000 - CORRECT ANSWER - The International Mechanical Code (IMC) requires a duct
smoke detector in the supply for units over __________ cfm


4 hours - CORRECT ANSWER - Digital alarm communicator transmitters (DACT) which
use call forwarding to the DACR shall be tested with what frequency?


600v - CORRECT ANSWER - NPLFA cables shall be insulated to __________ v



300v - CORRECT ANSWER - PLFA cables shall be insulated to _______ v



d - CORRECT ANSWER - For sprinkler systems what type of signal is a fire pump
running?
a. alarm
b. supervisory
c. trouble
d. A and B


AHJ - CORRECT ANSWER - A positive alarm sequence requires the approval of the
___________.


Semniannually - CORRECT ANSWER - How often shall a remote annunciator used at the
main entrance of a low-rise residential apartment building be inspected?

,Normal - CORRECT ANSWER - According to NFPA 72, the off-normal signal of a
tamper switch control valve used in sprinkler piping that is required for pressure-actuated water
flow alarm switch, shall not be restored at any valve position except _____________?


12 in; 8 ft - CORRECT ANSWER - When installing a heat-sensing fire detector on the
bottom of a beam, the beam must be less than _____________ inches in depth and
_____________ feet on center?


b - CORRECT ANSWER - Where a door is released to provide a 2-hour fire rating
directly from the smoke detector, the detector shall be ______________
a. mounted as close as possible to the door being released
b. listed for door releasing service
c. identified for door releasing service
d. of the photoelectric type only


d - CORRECT ANSWER - According to NFPA, smoke detectors installed in the ducts of
HVAC systems shall initiate:
a. alarm
b. supervisory
c. trouble
d. a or b


d - CORRECT ANSWER - According to the IBC, shop drawings shall include:
a. floor plan that indicates the use of all rooms
b. annunciators
c. voltage drop calculations
d. all of the above

,Master Control Unit - CORRECT ANSWER - The location of remotely located power
supplies shall be identified at the ________________


lower; 24 in - CORRECT ANSWER - Heat detectors will be installed in an elevator
hoistway to shut down power to the elevator prior to sprinkler activation. The heat detectors need
to have a _______________ temp rating and shall be located ______________ in from the
sprinkler head.


Group B - CORRECT ANSWER - A local community college is what type of occupancy
classification?


Group E - CORRECT ANSWER - What type of occupancy group for a school below the
12th grade?


Group B - CORRECT ANSWER - What type of occupancy group for a school above the
12th grade?


Class E - CORRECT ANSWER - A pathway shall be designated as _______________
(what class?) when it is NOT monitored for integrity?


40 feet; 5 feet - CORRECT ANSWER - Manual fire alarm boxes shall be installed on both
sides of grouped openings over ____________ feet in width and within __________ feet of each
side of the grouped opening.


c - CORRECT ANSWER - A fire pump was installed in a low-rise residential building
with a required fire alarm system. What are the requirements for the pump running signal?
a. It shall be a supervisory signal.
b. It shall be an alarm signal.
c. It shall be a supervisory or alarm signal.
d. A pump running signal is not required.

, d - CORRECT ANSWER - A licensed electrician was hired to install duct detectors
mounted on the air ducts of a 5,000 CFM unit. Which of the follwoing statements is true?
a. The smoke detector must be listed for use in air ducts
b. The detectors can initiate a supervisory signal
c. The detectors can initiate an alarm signal
d. All of the above


d - CORRECT ANSWER - Record drawings, as-builts, shall contain approval
documetnation resulting from any _______________?
a. variances
b. performance-based designs
c. risk analysis
d. all of the above


No - CORRECT ANSWER - An electrically locked door is connected to the fire alarm
system in order to unlock in the event of an alarm. The customer has requested that a feature be
added (push button) to lock the doors even while in alarm. Is this permitted by code?


90 seconds - CORRECT ANSWER - According to the 2022 edition of NFPA 13, electric
waterflow devices must activate within _________________ of water flow beginning and
continue until the flow stops


Elevator cars - CORRECT ANSWER - According to teh IBC, strobe lights/appliances
shall not be required in ______________?


300v - CORRECT ANSWER - Communications wires (Coaxial cables) shall have a
voltage rating of not less than _________ volts


30 in - CORRECT ANSWER - What is the minimum workspace width in front of
electrical equipment (This allows enough room for a person to face the equipment without
having to turn the upper body to work on the equipment)?

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
MGRADES Stanford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1072
Member since
1 year
Number of followers
102
Documents
68976
Last sold
2 days ago
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

170 reviews

5
73
4
30
3
45
2
8
1
14

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions