The minimum allowable distance between upright sprinklers in a light hazard occupancy is: -
CORRECT ANSWER - 6'
Which of the following materials is not classified as Group A? - CORRECT ANSWER -
Silicon rubber
A 2-inch schedule 40 steel 90°long-turn elbow has an equivalent pipe length of _____ feet. -
CORRECT ANSWER -3
Consider a specification using the CSI Master format. What part of the specification document
would contain the fire sprinkler requirements? - CORRECT ANSWER - Division 21
An occupancy with stockpiles of products with a moderate heat release rate that are 10' high
would be classified as - CORRECT ANSWER - Ordinary, Group 2
Which of the following construction types is considered unobstructed? - CORRECT
ANSWER - Solid wood joists 9 ft on center
A listed ___________device shall be installed in the connection between the dry pipe sprinkler
riser and the quick-opening device unless it is built in to the quick-opening device. - CORRECT
ANSWER - Antiflooding
Consider a building with a 25 foot ceiling. Which of the following miscellaneous storage types
would use the OH2 design curve for the design basis? (Select Two) - CORRECT
ANSWER - Class III bin box, 10 feet high
Rolled heavyweight paper on end, 10 feet high
, The minimum suction pipe size for a 200 gpm centrifugal pump is _______ inches. - CORRECT
ANSWER -3
The minimum allowable distance between upright sprinklers in a light hazard occupancy is -
CORRECT ANSWER - 6'
The pressure sensing line connection for each pump, including jockey pumps, shall be made
between that pump's __________ and discharge isolation valve. - CORRECT ANSWER -
Discharge check valve
Sprinkler piping and fire detection devices for a preaction system shall be automatically
supervised where more than _____ sprinklers are on the system. - CORRECT ANSWER -
20
Tissue products that are wrapped in plastic and cartoned are a _______ commodity. - CORRECT
ANSWER - Class III
A dry pipe system size of not more than ____ gal shall be permitted without a quick-opening
device and shall not be required to meet any specific water delivery requirement to the inspection
test connection. - CORRECT ANSWER - 500
A wet pipe system that does not have an auxiliary air reservoir shall be provided with a listed
relief valve not less than ______ in. in size and set to operate at a minimum of _____psi. -
CORRECT ANSWER - ½, 175
Not more than ______ automatic sprinklers shall be controlled by any one preaction valve -
CORRECT ANSWER - 1000
Extended coverage sprinklers shall not be installed in which of the following areas? - CORRECT
ANSWER - Unobstructed construction with a slope exceeding one in six