100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Dosimetry Board Review – Flash Cards Set 3 with Verified High-Yield Answers and Formulas

Rating
-
Sold
-
Pages
13
Grade
A+
Uploaded on
10-06-2025
Written in
2024/2025

This document presents Set 3 of board review flashcards focused on dosimetry, featuring verified answers on high-yield topics relevant to clinical practice and certification exams. Included are photon and electron energy losses, dose formulas (PDD, R50, CI, d10, d80, etc.), regulatory dose limits (NRC, ICRP), radiation protection, TG-43 brachytherapy, imaging resolutions, acronyms, well counter standards, and deterministic effects. Designed for fast review and mastery of technical and safety-focused dosimetry knowledge

Show more Read less
Institution
Dosimetry
Course
Dosimetry









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Dosimetry
Course
Dosimetry

Document information

Uploaded on
June 10, 2025
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Dosimetry Board Review Flash Cards Set 3 questions
with verified answers
% loss/cm for photon energies:
Cu (ortho)-
Co-60-
4X-
6X-
10X-
15X-
18X- Ans✓✓✓ Cu (ortho)- 15%/cm
Co-60- 4-5%/cm
4X- 4%/cm
6X- 3%/cm
10X- 3%/cm
15X- 2.5%/cm
18X- 2%/cm


Accuracy standard for well counters Ans✓✓✓ 1. +/- 5%
2. Traceable to NIST


Acronyms:
NRC-

, ICRP-
DOT-
NCRP-
IAEA-
USNASC-
BEIR- Ans✓✓✓ NRC- Nuclear Regulatory Commission
ICRP- International Committee on Radiation Units & Measures
DOT- Department of Transportation
NCRP-National Commission on Radiation Protection and Measurement
IAEA- International Atomic Energy Association
USNASC- U.S. National Academy of Science Committee
BEIR- Biological Effects of Ionizing Radiation


cm Cerrobend and cm Lead conversion Ans✓✓✓ 1cm Pb = 1.2 cm
Cerrobend
Due to fact that Cerrobend has small air bubbles in it leading to slightly
less shielding


Convert TVL to HVL Ans✓✓✓ 1 TVL = 3.32 HVL


Daily HDR Tests Ans✓✓✓ Safety interlocks, area monitor, source
positioning

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
cracker Chamberlain School Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
2016
Member since
3 year
Number of followers
1342
Documents
46956
Last sold
23 hours ago
✨ Cracker – Verified Study Powerhouse

Welcome to your shortcut to academic and certification success. I'm Cracker, a trusted top seller I specialize in high-quality study guides, test banks, certification prep, and real-world exam material all tailored to help you pass fast and score high.

3.8

370 reviews

5
162
4
84
3
53
2
22
1
49

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions