Exam Questions and CORRECT Answers
Dense anatomical area is underexposed. Which adjustment is most appropriate to improve image
quality without significantly increasing patient dose? - CORRECT ANSWER - Increase
kVp by 15% and decrease mAs by half
Which of the following are NOT used in direct capture digital radiography (DR) systems? -
CORRECT ANSWER - Plate readers
How does the orientation of the anode-cathode axis in the x-ray tube affect image sharpness
during extremity imaging? - CORRECT ANSWER - Orientation parallel to the limb
increases sharpness
What does a DAP meter primarily measure during radiographic procedures? - CORRECT
ANSWER - The radiation exposure in the area being imaged
In mobile radiography, how does the use of a grid impact image quality compared to non-grid
use? - CORRECT ANSWER - Increases image contrast by absorbing scatter radiation
How does a high-frequency generator differ from a standard generator in terms of radiation
output? - CORRECT ANSWER - it generates more consistent radiation
Which of the following is needed to move electrons through a circuit? - CORRECT
ANSWER - volts
Image appears overly smooth, lacking the expected detail and sharpness. What image processing
technique might have been over-applied? - CORRECT ANSWER - noise reduction
What is the result of using a higher bit depth? - CORRECT ANSWER - increased contrast
resolution
, Increasing which setting would most directly increase the image signal strength? - CORRECT
ANSWER - mAs
Image receptor designs used in DR? - CORRECT ANSWER - - Wired flat-panel detectors
- Wireless flat-panel detectors
What is the main purpose of conducting a signal-to-noise ratio (SNR) test in digital radiography?
- CORRECT ANSWER - to assess the clarity and sharpness of the image
Which two components are included in a digital imaging system that converts x-ray photons
directly into an electrical signal? - CORRECT ANSWER - - amorphous selenium (a-Se)
- thin-film transistor (TFT) array
Which AEC detectors should be activated for a right shoulder x-ray series? - CORRECT
ANSWER - select the center AEC detector to align with the right shoulder
Why is it crucial to implement a rigorous digital image archiving protocol? - CORRECT
ANSWER - to ensure images are available for comparative studies and legal requirements
A tech is calibrating a new radiographic imaging system. Which parameter should be prioritized
to ensure the highest quality of displayed images? - CORRECT ANSWER - the luminance
uniformity across the monitor
During the evaluation for a lateral lumbar spine radiograph, which factor is critical for
determining if the intervertebral disk spaces are properly aligned? - CORRECT
ANSWER - proper alignment of the x-ray beam
what is the objective of testing the reproducibility of kilovoltage (kV) across different exposures
in a radiography system? - CORRECT ANSWER - to ensure the system accurately
replicates the set kV