Commercial kitchen Grease duct systems serving a Type I hood shall be designed and installed to provide an air velocity within the duct system of not less than ______ feet per minute: a: 1000 b: 500 c: 400 d: 250 - CORRECT ANSWER-b: 500 Refer: IMC Code 506.3.4 The minimum openable area to the outdoors shall be ____ of the floor area being naturally ventilated: a: 6% b: 8% c: 4% d: 2% - CORRECT ANSWER-c: 4% Refer: IMC Code 504.7 Fire dampers are not required at penetrations of shafts where the steel exhaust subducts extend at least _______ vertically in exhaust shafts provided that there is a continuous airflow upward to the outdoors: a: 25 inches b: 22 inches c: 32 inches d: 28 inches - CORRECT ANSWER-b: 22 inches Refer: IMC Code 607.5.5 Exp 1.1 Underground Ducts shall have a minimum slope of _______ per foot to allow drainage to a point provided with access: a: 1/2 inch b: 1/6 inch c: 1/4 inch d: 1/8 inch - CORRECT ANSWER-d: 1/8 inch Refer: IMC Code 603.8.1 Liquid adhesive coatings used on air filters for air conditioning or heating systems shall have a flash point not lower than _______ : a: 200°F b: 250°F c: 350°F d: 325°F - CORRECT ANSWER-d: 325°F Refer: IMC Code 605.1Connectors shall connect to a chimney flue at a point not less than ______ above the lowest portion of the interior of the chimney flue: a: 10 inches b: 12 inches c: 16 inches d: 14 inches - CORRECT ANSWER-b: 12 inches Refer: IMC Code 801.12

Show more Read less
Institution
KY HVAC Journeyman
Course
KY HVAC Journeyman









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
KY HVAC Journeyman
Course
KY HVAC Journeyman

Document information

Uploaded on
June 6, 2025
Number of pages
14
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

KY HVAC Journeyman
Commercial kitchen Grease duct systems serving a Type I hood shall be designed and
installed to provide an air velocity within the duct system of not less than ______ feet
per minute:
a: 1000
b: 500
c: 400
d: 250 - CORRECT ANSWER-b: 500
Refer: IMC Code 506.3.4

The minimum openable area to the outdoors shall be ____ of the floor area being
naturally ventilated:
a: 6%
b: 8%
c: 4%
d: 2% - CORRECT ANSWER-c: 4%
Refer: IMC Code 504.7

Fire dampers are not required at penetrations of shafts where the steel exhaust
subducts extend at least _______ vertically in exhaust shafts provided that there is a
continuous airflow upward to the outdoors:
a: 25 inches
b: 22 inches
c: 32 inches
d: 28 inches - CORRECT ANSWER-b: 22 inches
Refer: IMC Code 607.5.5 Exp 1.1

Underground Ducts shall have a minimum slope of _______ per foot to allow drainage
to a point provided with access:
a: 1/2 inch
b: 1/6 inch
c: 1/4 inch
d: 1/8 inch - CORRECT ANSWER-d: 1/8 inch
Refer: IMC Code 603.8.1

Liquid adhesive coatings used on air filters for air conditioning or heating systems shall
have a flash point not lower than _______ :
a: 200°F
b: 250°F
c: 350°F
d: 325°F - CORRECT ANSWER-d: 325°F
Refer: IMC Code 605.1

, Connectors shall connect to a chimney flue at a point not less than ______ above the
lowest portion of the interior of the chimney flue:
a: 10 inches
b: 12 inches
c: 16 inches
d: 14 inches - CORRECT ANSWER-b: 12 inches
Refer: IMC Code 801.12

Liquids having flash points at or above 100°F (38°C) and below 140°F (60°C) comes
under ________ combustible liquid:
a: Class I
b: Class II
c: Class IIIA
d: Class IIIB - CORRECT ANSWER-b: Class II

Where located adjacent to walkways, the vertical termination of mechanical draft
systems shall be not less than ______ above the level of the walkway:
a: 7 feet
b: 5 feet
c: 3 feet
d: 4 feet - CORRECT ANSWER-a: 7 feet
Refer: IMC Code 804.3.5.1


Masonry chimney flues shall be provided with a cleanout opening having a minimum
height of ______ :
a: 6 inches
b: 12 inches
c: 8 inches
d: 10 inches - CORRECT ANSWER-a: 6 inches
Refer: IMC Code 801.13

Commercial Kitchen Exhaust equipment serving a Type I hood shall have a clearance
to combustible construction of not less than ______ :
a: 30 inches
b: 12 inches
c: 24 inches
d: 18 inches - CORRECT ANSWER-d: 18 inches
Refer: IMC Code 506.5.4

Steam-Heating Boiler operated at pressures not exceeding ______ for steam:
a: 20 psi
b: 15 psi
c: 10 psi
d: 25 psi - CORRECT ANSWER-b: 15 psi

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Brainarium Delaware State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1828
Member since
2 year
Number of followers
1043
Documents
22327
Last sold
22 hours ago

3.8

317 reviews

5
147
4
60
3
54
2
16
1
40

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions