Fluoroscopy Test - Image Production Exam Questions with Complete Answers

Institution
Fluoroscopy
Course
Fluoroscopy









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Fluoroscopy
Course
Fluoroscopy

Document information

Uploaded on
May 29, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Fluoroscopy Test - Image Production
Exam Questions with Complete
Answers

Atomic brightness control (ABC) maintains the brightness of the image by varying
______ - ANSWER-kVp and mA

The time it takes to turn on the digital fluoroscopy x-ray tube and reach the selected
mA and kVp is the ____ time - ANSWER-interrogation

Digital fluoroscopy with a charge-couples device has lower _____ and higher _____
than conventional fluoroscopy - ANSWER-patient dose, light sensitivity

A principal advantage of digital fluoroscopy is the _____ - ANSWER-image
subtraction

Digital fluoroscopic dose rate is lower than that for continuous analog fluoroscopy -
ANSWER-True

The source-to-skin distance limit for stationary fluoroscopic unit is _____ cm -
ANSWER-38

When performing a moblie fluoroscopic procedure, to reduce the radiation exposure
to the patient, the radiographer must use a minimal source-skin distance of _____
cm (_______ inches) - ANSWER-30; 12

How is brightness gain determined - ANSWER-product of minification and flux gain

Image contrast can be improved with ____ techniques - ANSWER-Subtraction

The image captured by FPIR is ________ compared to the ______ image of
traditional fluoroscopy - ANSWER-square, circular

The image intensifier's input phosphor differs from the output phosphor in what way -
ANSWER-is much larger

The time it takes to turn on the digital fluoroscopy x-ray tube and reach the selected
mA and kVp is the _____ time - ANSWER-interrogation

The total dose rate at the table top during fluoroscopy cannot exceed - ANSWER-10
R per minute

What device is required with a direct digital type of fluoroscopy system - ANSWER-
flat detector

, What happens when a multifocus image intensifier tube is operated in the
magnification mode - ANSWER-the electron focal point is closer to the input
phosphor

When using a 25/17/12 image intensifier tube, which of the following is true: -
ANSWER-the field of view is largest in the 25 cm mode

Which of the following describes the fluoroscopic system designed to maintain a
constant image brightness - ANSWER-automatic brightness control

Which of the following modes of a trifield image intensifier will result in the highest
patient dose - ANSWER-its 12 inch mode

If using a dynamic flat panel detector in fluoroscopy, the image intensifier is no
longer needed - ANSWER-True

The FPIR signal when used in DF is already digital - ANSWER-True

What is the minification gain for an image intensification tube with an input screen
diameter of 5 inches and an output diameter of 1 inch - ANSWER-25

What is the total brightness gain for an image intensification tube with a minification
gain of 25 and a fluc gain of 50 - ANSWER-1250

An image intensifier tube is identified by the diameter of its - ANSWER-input
phosphor

Brightness gain is typically in the range of _____. - ANSWER-5000-30000

During fluoroscopic image intensification, the primary x-ray beam exits the patient
and strikes the ____ of the image intensifier. - ANSWER-input screen

electrons hit the ___ after exiting the anode - ANSWER-output phosphor

Electrostatic lenses are actually _____ - ANSWER-charged electrodes

Electrostatic lenses are used to accelerate and focus - ANSWER-electrons

The image intensifier improved fluoroscopy by increasing image - ANSWER-
brightness

The input screen absorbs _____ and emits _____ - ANSWER-xray photons, light
photons

The kinetic energy of photoelectrons in the image intensifier is greatly increased by
the - ANSWER-potential difference across the tube

The number of light photons emitted within the image intensifier is ______ to the
amount of xray photons exiting the patient - ANSWER-directly proportional

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
lectknancy Boston University
View profile
Follow You need to be logged in order to follow users or courses
Sold
284
Member since
2 year
Number of followers
28
Documents
26008
Last sold
1 day ago

3.6

57 reviews

5
23
4
10
3
11
2
3
1
10

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions