2025/2026 With complete solution
Which fuel type has a lower ignition temperature?
Il` Il` Il` Il` Il` Il` Il`
Propane ignites between 920-1,120 degrees Fahrenheit Il` Il` Il` Il` Il` Il`
while natural gas ignites at 1,150 degrees Fahrenheit
Il` Il` Il` Il` Il` Il` Il` Il`
What is the significance of the differences in specific gravity between natural gas and propane?
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
Propane falls and collects in lower areas of appliance or room Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
while natural gas rises into the atmosphere
Il` Il` Il` Il` Il` Il` Il`
AD
What added safety feature is on all unvented gas appliances that is not found on vented
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
appliances?
Il`
Oxygen depletion system (ODS) that works with safety shutoff valve to stop fuel flow in event of
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
low oxygen levels
Il` Il` Il`
Which is a chemical compound with a strong pungent odor that occurs in incomplete or
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
interrupted combustion?
Il` Il`
Aldehydes
Which of the following must be present in order for natural gas or propane to ignite?
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
Heat
According to the chart below, I have listed four configurations one being invalid. Do you
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
understand this graph?
Il` Il` Il`
- 16" rise and 14" run
Il` Il` Il` Il` Il`
- 9' rise and 10' run
Il` Il` Il` Il` Il`
- 10'' rise and 14' run (invalid)
Il` Il` Il` Il` Il` Il`
-4' rise and 4' run
Il` Il` Il` Il`
, A 30,000 BTU appliance is installed at an elevation of 5,000 feet above sea level. The manufacturer
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
requires a derating of 4% for each 1,000 feet above sea level for appliances installed higher than
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
2000 feet above sea level. What is the proper BTU input of the appliance for this installation?
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
24,000 BTUs Il`
(4% for each 1,000 ( 5 one thousands)
Il` Il` Il` Il` Il` Il` Il`
1. 4x5 = 20 or 20%
Il` Il` Il` Il` Il`
2. 30,000 BTUs x .20 = 6,000
Il` Il` Il` Il` Il` Il`
3. 30,000-6,000 = 24,000
Il` Il` Il`
section 1: Chapter 2 (2.2.1.2.a) Il` Il` Il` Il`
According to the National Fuel Gas Code (NFPA 54), what is the maximum allowable BTU inputIl` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
rating for all gas appliances installed in a room measuring 12' x 12' x 10' if there are no provisions
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
for outside air?
Il` Il` Il`
28,800 BTU/hour Il`
1. 12'x12'x10' = 1,440 cubic feet
Il` Il` Il` Il` Il`
2. 1,440 x 20 = 28,800
Il` Il` Il` Il` Il` Il`
(if you were trying to find minimum cubic feet you would take appliance input rating and divide by
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
20)
Il`
Section 3: Chapter 8 (8.1.2) Il` Il` Il` Il`
According to the National Fuel Gas Code (NFPA 54), which gas hearth system appliance can be
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
installed in a bedroom or bathroom that is confined space?
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
Direct vent Il`
section 2: Chapter 5 (5.2) Il` Il` Il` Il`
Which of the following is the most likely of a yellow flame impingement on a log set creating soot?
Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il` Il`
Too much secondary air Il` Il` Il`
Section 1: Chapter 2 (2.1) Il` Il` Il` Il`