1 Exampromax - Stuvia US 2025/2026
NASCLA - IBC Code Book Questions and
Answers (100% Correct Answers) Already
Graded A+
4 - 105-2.4 - When do you need a permit for a retaining wall
Ans: you need a permit for a retaining wall when it is over 4 feet tall
5 - 105.6 - When can a building permit be revoked or suspended by an
official
Ans: a building permit be revoked or suspended by an official when it is issued in
error.
© 2025 Assignment Expert
9 - 114.2 When may an official may issue a notice of violation
Exampromax - Stuvia US
Ans: an official may issue a notice of violation when the work being done is in
violation of a code.
DEFINITIONS
Ans: DEFINITIONS
107 - 602.4 What type of construction uses heavy timbers
Ans: type IV construction uses heavy timbers - the exterior is made of non
combustible materials and the interior of solid or laminated wood.
113 - 704.9 - When a structural membrane that is covered with fire
protective covering that maybe subject to damage, how high must it be
protected.
Ans: IMPACT PROTECTION - When a structural membrane that is covered
with fire protective covering that maybe subject to damage, how high must it be
protected at least 5 feet with a metal jacket or non combustible material.
113 - 704.13.4 - What must be the temperature when using Sprayed Fire
resistant material (SRFM).
Ans: the temperature when using Sprayed Fire resistant material (SRFM). the
substrate the temperature when using Sprayed Fire resistant material
(SRFM).temperature must be at least 40 degrees.
, 2 Exampromax - Stuvia US 2025/2026
117 - 705.11.1 - How high must parapet walls be
Ans: Parapet walls must be atleast 30" high from the point at which the roof and
wall intersect.
123-709.3 - What is the thickness of smoke barriers
Ans: Smoke barriers must be constructed of minimum 0.10 inch thickness.
126 - 713.4 - Shafts in building with more than 4 stories must have how
many hours of fire rating.
Ans: Shafts in building with more than 4 stories must have how many hours of
fire rating at least 2 hours
© 2025 Assignment Expert
137 - Table 716.6 - Fire window assembly fire protection ratings
Ans: Table 716.6 - Fire window assembly fire protection ratings
Exampromax - Stuvia US
163 - What is the fire rating on a 2 layers of 5
Ans: 8" drywall produce/ the fire rating on a 2 layer of 5/8" drywall produce is 2
hours
181-722.5.1 What material do you use to fire protect steel columns
Ans: To fire protect steel columns you use gypsum wallboard.
200 - 805.1.2 - What is finished wood flooring permitted to be attached to
Ans: finished wood flooring permitted to be attached to the embedded or fire
blocked wood sleepers
203 - 901.5 - Can you occupy a structure or portion of a structure that has
not been fire protection systems have been tested and approved.
Ans: No it is unlawful to occupy a structure or portion of a structure that has not
been fire protection systems have been tested and approved
209 - 903.4.1 - Where should alarm signals be automatically be transmitted
to
Ans: alarm signals be automatically be transmitted to an approved supervising
station.
NASCLA - IBC Code Book Questions and
Answers (100% Correct Answers) Already
Graded A+
4 - 105-2.4 - When do you need a permit for a retaining wall
Ans: you need a permit for a retaining wall when it is over 4 feet tall
5 - 105.6 - When can a building permit be revoked or suspended by an
official
Ans: a building permit be revoked or suspended by an official when it is issued in
error.
© 2025 Assignment Expert
9 - 114.2 When may an official may issue a notice of violation
Exampromax - Stuvia US
Ans: an official may issue a notice of violation when the work being done is in
violation of a code.
DEFINITIONS
Ans: DEFINITIONS
107 - 602.4 What type of construction uses heavy timbers
Ans: type IV construction uses heavy timbers - the exterior is made of non
combustible materials and the interior of solid or laminated wood.
113 - 704.9 - When a structural membrane that is covered with fire
protective covering that maybe subject to damage, how high must it be
protected.
Ans: IMPACT PROTECTION - When a structural membrane that is covered
with fire protective covering that maybe subject to damage, how high must it be
protected at least 5 feet with a metal jacket or non combustible material.
113 - 704.13.4 - What must be the temperature when using Sprayed Fire
resistant material (SRFM).
Ans: the temperature when using Sprayed Fire resistant material (SRFM). the
substrate the temperature when using Sprayed Fire resistant material
(SRFM).temperature must be at least 40 degrees.
, 2 Exampromax - Stuvia US 2025/2026
117 - 705.11.1 - How high must parapet walls be
Ans: Parapet walls must be atleast 30" high from the point at which the roof and
wall intersect.
123-709.3 - What is the thickness of smoke barriers
Ans: Smoke barriers must be constructed of minimum 0.10 inch thickness.
126 - 713.4 - Shafts in building with more than 4 stories must have how
many hours of fire rating.
Ans: Shafts in building with more than 4 stories must have how many hours of
fire rating at least 2 hours
© 2025 Assignment Expert
137 - Table 716.6 - Fire window assembly fire protection ratings
Ans: Table 716.6 - Fire window assembly fire protection ratings
Exampromax - Stuvia US
163 - What is the fire rating on a 2 layers of 5
Ans: 8" drywall produce/ the fire rating on a 2 layer of 5/8" drywall produce is 2
hours
181-722.5.1 What material do you use to fire protect steel columns
Ans: To fire protect steel columns you use gypsum wallboard.
200 - 805.1.2 - What is finished wood flooring permitted to be attached to
Ans: finished wood flooring permitted to be attached to the embedded or fire
blocked wood sleepers
203 - 901.5 - Can you occupy a structure or portion of a structure that has
not been fire protection systems have been tested and approved.
Ans: No it is unlawful to occupy a structure or portion of a structure that has not
been fire protection systems have been tested and approved
209 - 903.4.1 - Where should alarm signals be automatically be transmitted
to
Ans: alarm signals be automatically be transmitted to an approved supervising
station.