100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Certification, EPA 608 Questions Correctly Answered.

Rating
-
Sold
-
Pages
28
Grade
A+
Uploaded on
20-05-2025
Written in
2024/2025

EPA 608 Certification, EPA 608 Questions Correctly Answered. November 14, 1994 - CORRECT ANSWER What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? Memorize it, ya'll. - CORRECT ANSWER 1989- Montreal Protocol July 1 1992- Violation to vent CFCs or HCFCs Nov 15 1993- Recovery/Recycling equipment must be certified and labeled by EPA AND Before this date recovery equipment needed to be capable of removing 80% of the refrigerant, w or wo compressor, or 4 in Hg After this date recovery equipment needs to be capable of removing 90%, or 80% without working compressor, or 4 in Hg AND Required level of evacuation for Low Pressure appliances before this date was 25 inches Hg, after this date 25 mm Hg Nov 14 1994- Certification needed to service, maintain, or dispose of appliances with refrigerants AND Sale of CFC and HCFC refrigerants restricted to certified techs Nov 15 1995- Violation to vent HFCs Dec 31 1995- CFCs no longer produced 15% - CORRECT ANSWER Comfort cooling appliances containing more than 50 lbs of refrigerant must be repaired when the annual leak rate exceeds _____% 35% - CORRECT ANSWER Commercial and Industrial process refrigeration containing ore than 50 lbs of refrigerant must be repaired when the annual leak rate exceeds _____% 0 0 4 10 4 10 4 15 0 0 - CORRECT ANSWER Required Recovery Levels for Type II appliances, before and after 11/15/93: HCFC22 less than 200 lbs = B4-0 After-0 HCFC22 more than 200 lbs= B4-4 After-10 NonHCFC22 less than 200 lbs= B4-4 After 10 NonHCFC22 more than 200 lbs= B4 4 After 15 Very high pressure appliances= B4-0 After-0 Recover all refrigerants. - CORRECT ANSWER Section 608 of the Federal Clean Air Act requires technicians to what? The earth's stratosphere. - CORRECT ANSWER The objective of the Clean Air Act is to protect what? HydroFlouroCarbon's - CORRECT ANSWER HFC's ChloroFluoroCarbon's - CORRECT ANSWER CFC's Ozone Depletion Potential - CORRECT ANSWER ODP The Montreal Protocol. - CORRECT ANSWER Which international treaty agreement was the basis for Section 608? 1.Crop losses 2.Increases in eye diseases 3.Skin Cancer 4.Reduced marine life 5.Deforestation 6.Increased ground level ozone - CORRECT ANSWER Depletion of the ozone in the stratosphere is known to cause what 6 things? These atoms attack Ozone Molecules causing the formation of Chlorine Monoxide (CLO), after colliding with another Ozone Molecule, causes 2 Oxygen (O2) molecules to be made & leaving an atom of chlorine to act as "Free Agent" starting the process over until 100,000 molecules of Ozone are destroyed by just one atom of chloride. - CORRECT ANSWER What happens when CFC or HCFC molecules get in the stratosphere & free atoms of Chlorine are set free?

Show more Read less
Institution
EPA.
Course
EPA.










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA.
Course
EPA.

Document information

Uploaded on
May 20, 2025
Number of pages
28
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

  • epa

Content preview

EPA 608 Certification, EPA 608
Questions Correctly Answered.

November 14, 1994 - CORRECT ANSWER What date was the sale of CFC's & HCFC's restricted to
technicians certified in refrigerant recovery?



Memorize it, ya'll. - CORRECT ANSWER 1989-

Montreal Protocol



July 1 1992-

Violation to vent CFCs or HCFCs



Nov 15 1993-

Recovery/Recycling equipment must be certified and labeled by EPA

AND

Before this date recovery equipment needed to be capable of removing 80% of the refrigerant, w or wo
compressor, or 4 in Hg

After this date recovery equipment needs to be capable of removing 90%, or 80% without working
compressor, or 4 in Hg

AND

Required level of evacuation for Low Pressure appliances before this date was 25 inches Hg, after this
date 25 mm Hg



Nov 14 1994-

Certification needed to service, maintain, or dispose of appliances with refrigerants AND

Sale of CFC and HCFC refrigerants restricted to certified techs



Nov 15 1995-

Violation to vent HFCs

,Dec 31 1995-

CFCs no longer produced



15% - CORRECT ANSWER Comfort cooling appliances containing more than 50 lbs of refrigerant must be
repaired when the annual leak rate exceeds _____%



35% - CORRECT ANSWER Commercial and Industrial process refrigeration containing ore than 50 lbs of
refrigerant must be repaired when the annual leak rate exceeds _____%



00

4 10

4 10

4 15

0 0 - CORRECT ANSWER Required Recovery Levels for Type II appliances, before and after 11/15/93:



HCFC22 less than 200 lbs = B4-0 After-0

HCFC22 more than 200 lbs= B4-4 After-10

NonHCFC22 less than 200 lbs= B4-4 After 10

NonHCFC22 more than 200 lbs= B4 4 After 15

Very high pressure appliances= B4-0 After-0



Recover all refrigerants. - CORRECT ANSWER Section 608 of the Federal Clean Air Act requires
technicians to what?



The earth's stratosphere. - CORRECT ANSWER The objective of the Clean Air Act is to protect what?



HydroFlouroCarbon's - CORRECT ANSWER HFC's



ChloroFluoroCarbon's - CORRECT ANSWER CFC's

, Ozone Depletion Potential - CORRECT ANSWER ODP



The Montreal Protocol. - CORRECT ANSWER Which international treaty agreement was the basis for
Section 608?



1.Crop losses

2.Increases in eye diseases

3.Skin Cancer

4.Reduced marine life

5.Deforestation

6.Increased ground level ozone - CORRECT ANSWER Depletion of the ozone in the stratosphere is
known to cause what 6 things?



These atoms attack Ozone Molecules causing the formation of Chlorine Monoxide (CLO), after colliding
with another Ozone Molecule, causes 2 Oxygen (O2) molecules to be made & leaving an atom of
chlorine to act as "Free Agent" starting the process over until 100,000 molecules of Ozone are destroyed
by just one atom of chloride. - CORRECT ANSWER What happens when CFC or HCFC molecules get in
the stratosphere & free atoms of Chlorine are set free?



November 15, 1993 - CORRECT ANSWER What date was recovery equipment required to be certified by
a lab, & achieve higher evacuation levels, & have low loss fittings?



November 14, 1994 - CORRECT ANSWER On what date was technician certification required?



December 31, 1995 - CORRECT ANSWER What date were CFC's phased out of production?



Persons who maintain, service, repair, or dispose of small appliances (containing 5 pounds of refrigerant
(or less). - CORRECT ANSWER What is EPA 608 Type I certification?
$14.99
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
risingstar01

Get to know the seller

Seller avatar
risingstar01 Oxford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
8 months
Number of followers
0
Documents
13
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions