TCFP Inspector's Class II ACTUAL EXAM
QUESTIONS WITH COMPLETE SOLUTION
GUIDE) (MULTIPLE CHOICES) (A+ GRADED 100%
VERIFIED) LATEST VERSION 2025
Save
Terms in this set (135)
Which of the following A and B
are a type of sprinkler?
A) ESFR
B) EC
C) AF
D) A and B
Foam water system NFPA 16
design and installation
requirements are
regulated by ___________.
A. NFPA 13
B. NFPA 13R
C. NFPA 25
D. NFPA 16
True or False, NFPA 72 True
allows only manual pull
stations and water flow
detection devices to be
used on shunt systems.
Fire detection devices
are not permitted.
https://quizlet.com/1044750246/tcfp-inspectors-class-ii-actual-exam-questions-with-complete-solution-guide-multiple-choices-a-graded-100-verifi… 1/41
,5/16/25, 12:02 PM TCFP Inspector's Class II ACTUAL EXAM QUESTIONS WITH COMPLETE SOLUTION GUIDE) (MULTIPLE CHOICES) (A+ …
The fire alarm control Brain
panel (FACP) is
essentially the _____ of the
system.
Heat sensing fire 325-399f
detector color coding
has a RED extra high
temperature rating of?
A.) 0-99f
B.)175-249f
C.) 325-399f
D.) 500-575f
According to NFPA, 200
travel distances to a
manual pull station
should not exceed _____
feet.
A. 100
B. 200
C. 300
D. 400
What color tag is used to Red
indicate that an alarm
system is impaired?
A. White
B. Yellow
C. Blue
D. Red
About _____ % of fire 65%
deaths are attributed to
smoke inhalation and not
to burns.
A. 55%
B. 60%
C. 65%
D. 70%
https://quizlet.com/1044750246/tcfp-inspectors-class-ii-actual-exam-questions-with-complete-solution-guide-multiple-choices-a-graded-100-verifi… 2/41
,5/16/25, 12:02 PM TCFP Inspector's Class II ACTUAL EXAM QUESTIONS WITH COMPLETE SOLUTION GUIDE) (MULTIPLE CHOICES) (A+ …
When performing Confirm system has been tested by licensed alarm
maintenance inspections contractor and has a current inspection tag
of occupancies with
alarm systems, the first
step will be to:
A) Check for green light
indicating normal
operation
B) Confirm monitoring
status with alarm
company
C) Confirm panel is
locked and inaccessible
to public
D) Confirm system has
been tested by licensed
alarm contractor and has
a current inspection tag
Most people are well 65
aware of the dangers of
fire but less aware of the
dangers of smoke
inhalation. About ___% of
of fire deaths are
attributed to smoke
inhalation and not to
burns.
A) 65
B) 80
C) 92
D) 75
https://quizlet.com/1044750246/tcfp-inspectors-class-ii-actual-exam-questions-with-complete-solution-guide-multiple-choices-a-graded-100-verifi… 3/41
, 5/16/25, 12:02 PM TCFP Inspector's Class II ACTUAL EXAM QUESTIONS WITH COMPLETE SOLUTION GUIDE) (MULTIPLE CHOICES) (A+ …
If required, pull stations 5
should be placed within
___ feet of every exit.
a) 4
b) 5
c) 10
d) does not matter what
distance, as long as it is
not blocked
T or F: The development True
of clean-agent fire-
extinguishing systems
began in the late 1940s.
NFPA 10 has assigned a 30
maximum travel distance
of __ feet from the hazard
to a Class K extinguisher?
A) 30
B) 50
C) 75
D) 100
If an extinguisher is Light Blue
suitable for use on a
particular class of fire, the
picture-symbol
background is what
color?
A.) Red
B.) Light Blue
C.) Black
D.) Grey
https://quizlet.com/1044750246/tcfp-inspectors-class-ii-actual-exam-questions-with-complete-solution-guide-multiple-choices-a-graded-100-verifi… 4/41