Latest Update Graded A+
What would be the calculated minimum conductor ampacity for a continuous duty, single
phase, 120 volt, 3/4 horse power swimming pool pump motor?
1. 15 amperes
2. 16 amperes
3. 17 amperes
4. 18 amperes 3. 17 amperes
Provided all applicable conductors are met a single 16 AWG copper conductor can be used on
continuous loads that do not exceed
1. 6 amperes
2. 7 amperes
3. 8 amperes
4. 10 amperes 3. 8 amperes
A bonding conductor or jumper is a reliable conductor to ensure the required electrical
conductivity between metal parts required to be electrically connected. This bonding conductor
or jumper shall be made to be which of the following?
1. continuous
,2. supported
3. secure
4. durable 1. continuous
For incandescent filament lamps, pendant conductors shall be twisted together, where not
cabled in a listed assembly, when longer than
1. 2.0 feet
2. 2.5 feet
3. 3.0 feet
4. 3.5 feet 3. 3.0 feet
If a parallel set of 600 kcmil conductors are installed separate raceways, and these circuits are
protected with 1200 ampere overcurrent fuses, what would be the minimum size of the
equipment grounding conductors used for this installation?
1. 8 AWG
2. 4 AWG
3. 1 AWG
4. 3/0 AWG 4. 3/0 AWG
,For a multifamily unit, the required 20 ampere dedicated circuit for the dwelling's bathroom
unit shall
1. be added to the general lighting calculation.
2. not be added to the general lighting calculation.
3. have 1,599 VA added to the general lighting calculation.
4. have 20 amperes added to the general lighting calculation. 2. not be added to the general
lightning calculation .
Other than listed factory assemblies, individual fuses, circuit breakers, or combinations thereof
shall not be
1. connected in parallel
2. connected in series
3. used in motor protection applications
4. used in 600-volt applications 1. connected in parallel
Excluding any exceptions, branch circuit conductors supplying household ranges and cooking
appliances rated at 8,750 Watts or more shall have a minimum branch circuit rating of least
how many amperes?
1. 40 amperes.
, 2. 45 amperes.
3. 55 amperes.
4. 65 amperes. 1. 40 amperes.
In guest rooms of hotels and motels, receptacle outlets shall be permitted to be located
conveniently for permanent furniture layout shall be readily accessible, and have at least
1. four receptacles
2. three receptacles
3. two receptacles
4. one receptacle 3. two receptacles
Emergency system equipment shall be suitable for the maximum available fault current at its
terminals, and shall have adequate capacity and rating for all loads to be operated which of the
following?
1. independently
2. manually
3. simultaneously
4. with battery 3. simultaneously