Fixture connections that require the removal of an access panel for servicing are considered
correct answers Accessible
That part of the lowest piping of a drainage system that receives the discharge from soil, waste,
and other drainage pipes inside the walls fo the building and conveys it to a point 2 feet outside
the building wall is a correct answers Building sewer
A vertical vent that is a continuation of the drain to which it connects is a correct answers Circuit
vent
A horizontal drain that is sized to provide free movement of air above the flow line of the drain is
called a correct answers Continuous waste system
The length along the centerline of the pipe and fittings is the correct answers Diameter length
A device integrated within an air accumulator vessel that is designed to discharge a
predetermined quantity of water to fixtures for flushing purposes is a correct answers Expansion
tank
The combination of fittings that may be used to make an offset and is considered a vertical pipe
are correct answers 1-45 degree and 1-45degree
Water safe for drinking and culinary purposes is referred to as correct answers Potable water
By code definition, a stack is always correct answers Vertical
, A vent that also serves as a drain is a correct answers Wet vent
A pipe that makes an angle of not more than 45 degrees with the vertical is considered correct
answers Diagonal pipe
he vertical depth of a trap seal is measured from correct answers The outlet of the trap to the
bottom of the trap
A mixing valve that senses outlet temperature and compensates for fluctuations in incoming hot
or cold water temperature is a correct answers Thermostatic (temperature control) valve
The lowest portion of the inside of a horizontal pipe is called the correct answers Bottom
PEX is the acronym for correct answers Cross-linked polyethylene
A confined space is a room or space having a volume equal to at least ______ of the aggregate
input rating of all the fuel-burning appliances in that space. correct answers 100 cubic feet per
BTU/hr.
A joint obtained by the joining of metal parts with metallic mixtures or alloys that melt at a
temperature up to 840 degrees is a correct answers Soldered joint
The organization, office, or individual responsible for enforcing the requirements of a
code or standard is the correct answers Plumbing Inspector
That portion of a drainage system that does not drain by gravity into the building sewer is known
as a correct answers Sewer ejector
A pipe inside a building that conveys storm water from the roof to a storm drain is called a (an)
correct answers Building storm drain