Patient harmed by compounded sterile preparations - Answer-microbial contamination, excessive bacterial endotoxins, variability in strength of ingredients, chemical/physical contaminants, inappropriate quality of ingredients non sterile compounding examples - Answer-products used orally, topically on skin or to fill gaps when not commercially available aesptic - Answer-state of being free from microbial contamination sterile compounded items - Answer-injections(iv, etc) ophthalmic drops, aqueous bronchial or nasal inhalations, baths for live organs, tissue implants, irrigation for wounds or cavities Non hazardous hoods - Answer-Laminar airflow workbench (LAFW) compounding containment isolator (CAI) Hazardous hoods - Answer-biological safety cabinet (BSC) compounding aseptic containment isolator (CACI) Primary Engineering Control (PEC) - Answer-a device or room that provides an ISO Class 5 environment for the exposure of critical sites when compounding CSPs. Such devices include, but may not be limited to, laminar airflow workbenches (LAFWs), biological safety cabinets (BSCs), compounding aseptic isolators (CAIs), and compounding aseptic containment isolators (CACIs). secondary engineering controls - Answer-the ante area and buffer area Buffer or Clean Room - Answer-ISO 7 Ante Room ISO class - Answer-ISO 8, unless provides access to negative pressure room then ISO 7 vertical hood - Answer-hazardous compounding-air flows vertically Horizontal Hood - Answer-air flows horizontally across the work area from back to front Direct Compounding Area (DCA) - Answer-- a critical area within the hood (ISO Class 5) where areas are exposed to filtered air; also known as "first air" Negative Pressure room - Answer-Hazardous materials High-efficiency particulate air (HEPA) filters - Answer-remove microbes > 0.3 micrometers Ante Room - Answer-washing, garbing, product decontamination Buffer area air change per hour (APCH) - Answer-30 exchanges per hour ante room air change per hour (APCH) - Answer-ISO 8-20 per hour ISO 7- 30 per hour Cleaning of compounding area - Answer-germicidal detergent & water for visible solids, 70% isopropyl alcohol ISO Class 5 PEC cleaned - Answer-beginning of each shift, before each batch, every 30 minus when compounding, after spills, contamination Cleaning of Counters and floors of specific sites - Answer-daily Cleaning Walls, ceilings, storage shelving: - Answer-monthly Suface sampling frequency - Answer-every 6 months or significant changes in procedure Temperature of CSP areas - Answer-room temperature 20'C(68'F) or cooler Airborne Particle Testing - Answer-every 6 months or device relocated or serviced ISO class 5 Particle Limit for sterile compounding - Answer-3,520 particles that are 0.5 micron or larger ISO Class 7 Particle Limit for sterile compounding - Answer-352,000 particles that are 0.5 micron or larger ISO Class 8 Particle Limit for sterile compounding - Answer-3,520,000 particles that are 0.5 micron or larger ISO Class 5 Colony Forming Unit Action Level - Answer-1 (>3)

Show more Read less
Institution
PTCB CSPT
Course
PTCB CSPT










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
PTCB CSPT
Course
PTCB CSPT

Document information

Uploaded on
May 1, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

PTCB CSPT EXAM


PTCB CSPT EXAM STUDY GUIDE 2025
GRADED A+
Patient harmed by compounded sterile preparations - Answer-microbial contamination,
excessive bacterial endotoxins, variability in strength of ingredients, chemical/physical
contaminants, inappropriate quality of ingredients



non sterile compounding examples - Answer-products used orally, topically on skin or to
fill gaps when not commercially available



aesptic - Answer-state of being free from microbial contamination



sterile compounded items - Answer-injections(iv, etc) ophthalmic drops, aqueous
bronchial or nasal inhalations, baths for live organs, tissue implants, irrigation for
wounds or cavities



Non hazardous hoods - Answer-Laminar airflow workbench (LAFW) compounding
containment isolator (CAI)



Hazardous hoods - Answer-biological safety cabinet (BSC) compounding aseptic
containment isolator (CACI)



Primary Engineering Control (PEC) - Answer-a device or room that provides an ISO Class
5 environment for the exposure of critical sites when compounding CSPs. Such devices
include, but may not be limited to, laminar airflow workbenches (LAFWs), biological
safety cabinets (BSCs), compounding aseptic isolators (CAIs), and compounding aseptic
containment isolators (CACIs).

,PTCB CSPT EXAM


secondary engineering controls - Answer-the ante area and buffer area



Buffer or Clean Room - Answer-ISO 7



Ante Room ISO class - Answer-ISO 8, unless provides access to negative pressure room
then ISO 7



vertical hood - Answer-hazardous compounding-air flows vertically



Horizontal Hood - Answer-air flows horizontally across the work area from back to front



Direct Compounding Area (DCA) - Answer-- a critical area within the hood (ISO Class 5)
where areas are exposed to filtered air; also known as "first air"



Negative Pressure room - Answer-Hazardous materials



High-efficiency particulate air (HEPA) filters - Answer-remove microbes > 0.3
micrometers



Ante Room - Answer-washing, garbing, product decontamination



Buffer area air change per hour (APCH) - Answer-30 exchanges per hour



ante room air change per hour (APCH) - Answer-ISO 8-20 per hour ISO 7- 30 per hour

, PTCB CSPT EXAM


Cleaning of compounding area - Answer-germicidal detergent & water for visible solids,
70% isopropyl alcohol



ISO Class 5 PEC cleaned - Answer-beginning of each shift, before each batch, every 30
minus when compounding, after spills, contamination



Cleaning of Counters and floors of specific sites - Answer-daily



Cleaning Walls, ceilings, storage shelving: - Answer-monthly



Suface sampling frequency - Answer-every 6 months or significant changes in procedure



Temperature of CSP areas - Answer-room temperature 20'C(68'F) or cooler



Airborne Particle Testing - Answer-every 6 months or device relocated or serviced



ISO class 5 Particle Limit for sterile compounding - Answer-3,520 particles that are 0.5
micron or larger



ISO Class 7 Particle Limit for sterile compounding - Answer-352,000 particles that are 0.5
micron or larger



ISO Class 8 Particle Limit for sterile compounding - Answer-3,520,000 particles that are
0.5 micron or larger



ISO Class 5 Colony Forming Unit Action Level - Answer-1 (>3)
$16.49
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
Tommrexy
4.0
(1)

Get to know the seller

Seller avatar
Tommrexy Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
2
Member since
1 year
Number of followers
0
Documents
111
Last sold
7 months ago

4.0

1 reviews

5
0
4
1
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions