100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

TSSA G2 PRACTICE QUESTIONS (UNITS 10-16) WITH CORRECT ANSWERS

Rating
-
Sold
-
Pages
13
Grade
A+
Uploaded on
26-04-2025
Written in
2024/2025

TSSA G2 PRACTICE QUESTIONS (UNITS 10-16) WITH CORRECT ANSWERS

Institution
TSSA
Course
TSSA









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
TSSA
Course
TSSA

Document information

Uploaded on
April 26, 2025
Number of pages
13
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

TSSA G2 PRACTICE QUESTIONS (UNITS
10-16) WITH CORRECT ANSWERS



(10) What is a Servo? - Correct Answers -A mechanism set in motion by other
mechanisms

(10) What is Setpoint? - Correct Answers -The desired outlet perssure

(10) Which regulator is more accurate; pilot operated or direct operated? - Correct
Answers -Pilot operated

(10) In which applications are pilot operated regulators normally employed other than
servo regulation? - Correct Answers -High capacity applications in commercial,
institutional, and industrial settings.

(10) How is the accuracy of a regulator determined? - Correct Answers -The amount of
flow it can pass for a given amount of droop determines the accuracy of a regulator. The
closer the regulator is to setpoint, the more accurate it is.

P2 - If the reading is 144 V what should you do? - Correct Answers -Move the ground to
the other terminal of the secondary and the reading between L1 and the ungrounded
side of the secondary will read 96 V

(10) What are the four factors that may affect droop? - Correct Answers -Spring rate,
diaphragm rate, orifice size, and inlet pressure

(10) In many service and line pressure regulators how can you change the flow
capacity? - Correct Answers -By changing the orifice size

(10) Which way should the adjustment screw be turned to increase downstream
pressure? - Correct Answers -Clockwise

(10) Where shouldn't leak limiting devices installed and why? - Correct Answers -
Outdoors, because if they are exposed to the outdoors they may become clogged by
moisture or insects.

(10) What is the pitot tube design used for? - Correct Answers -To decrease regulator
droop

, (10) Line pressure regulators for use on systems with an inlet pressure over 0.5 psi
must be of what type? - Correct Answers -Positive shut-off type

(10) What drill size opening do most small appliance regulators vent through to the
indoors (in a ventilated area). - Correct Answers -#78 Drill size

(10) For piping systems over 2 psi, a line pressure regulator must be equipped with
__________ or ___________. - Correct Answers -A line relief device or an
overpressure protection device

(13) P.1 - If a transformer's primary and secondary sides are in phase what should be
the voltage between the hot and the ungrounded side of the secondary? - Correct
Answers -96 V

(13) P.2 - If the reading is 144 V what should you do? - Correct Answers -Move the
ground to the other terminal of the secondary and now the reading between L1 and the
ungrounded side of the secondary will be 96 V; you have now identified the proper
secondary side terminal to use as Hot (R)

(13) What standard outlines the minimum requirements that should be followed when
working with live voltage? - Correct Answers -CSA Z462

(14) What is the HDL (negative inches w.c.) for an airtight woodstove or fireplace? -
Correct Answers -0.04

(10) What are the minimum and maximum hydrostatic relief device pressures on liquid
propane systems? - Correct Answers -375 psi and 500 psi

(10) What are the typical upstream and manifold gas pressures for NG and LP - Correct
Answers -LP: 13" w.c. upstream, 11" w.c. manifold
NG: 7" w.c. upstream, 3.5" w.c. manifold

(10) - Correct Answers -

(10) After a gas piping system has been installed, how many pressure tests are required
and when? - Correct Answers -The first before any appliances are installed and the
second after all the appliances are installed

(10) All piping and components must be _____________ and ___________before
being concealed - Correct Answers -inspected and tested

(10) How do you check for seepage at the gas meter? - Correct Answers -Release a
small amount of gas from the system at static pressure (with the supply valve in the fully
closed position) then wait to see if the pressure creeps back up

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
millyphilip West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
2819
Member since
3 year
Number of followers
1959
Documents
41272
Last sold
3 hours ago
white orchid store

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.7

535 reviews

5
234
4
84
3
103
2
31
1
83

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions