2025 Questions and Answers 100%
Pass
Residential owners are responsible = - ✔✔570
Residential cabling responsibilities have shifted from the access provider = - ✔✔To
the end users the owners of homes
How many grades of residential premise for telecommunications cable = - ✔✔Two
What does grade 1 residential cabling consist of ? - ✔✔Grade 1 - Provide a generic
cabling system that meets the minimum requirements for telecommunications
service, install one cat5e balanced twisted pair and 1 75 ohm coax, cat6 is
recommended
What is grade 2 residential cabling consist of ? - ✔✔Grade 2 residential cabling
provides a minimum of two 4-pair balanced twisted pair cables and associated
connectors that meet of exceed the requirements for cat5e and two 75 ohm series 6
coaxial cables, additionally two strand fiber cabling may be installed
Each living area should be cabled with at least = - ✔✔One telecommunications outlet
All cabling shall be home run directly form individual telecommunications outlets to
= - ✔✔DD distribution device
Demarcation point DP - ✔✔Exterior building wall
Recommended backbone cables include = - ✔✔EXCETP wirelss