disinfection only
When using the warm cycle of the EtO sterilizer, what is the minimum sterilization temperature in
Fahrenheit? - correct answer 85 degrees
How many hours just an item submerse in Glutaraldehyde to sterilize? - correct answer 10 hours
The Bowie-Duck test is performed: - correct answer Daily
Which of the following is a method of high level disinfection? - correct answer 2% glutaraldehyde for
20 minutes
The most reliable method of determining the efficiency of moist heat stabilizers is the controlled use of
biological indicators containing the organism: - correct answer Bacillus stearothermophilus
What degrees Celsius is the steam sterilization biological indicator incubated? - correct answer 55-60
degrees Celsius
Which of the following method to removes small organic particles and soil from the box locks and
ratchets of instrument? - correct answer Ultrasonic washer
What is the proper method of preparing a Frazier section tip for steam sterilization? - correct answer
Distilled water in the lumen
The minimum Fahrenheit temperature for sterilization to occur in a prevacuum steam sterilizer is: -
correct answer 270-276 Fahrenheit
What is the minimum number of minutes to sterilize unwrapped metal instruments with lumens in the
gravity displacement sterilizer at 270 Fahrenheit? - correct answer 10 minutes
, To prevent density, instrument sets should not exceed: - correct answer 25 pounds
Which of the following is the most effective method for sterilizing item that can be damaged by steam
sterilization? - correct answer Ethylene oxide
When the surgical technologist is preparing surgical instruments for transport to the decontamination
room, which statement is incorrect? - correct answer Instruments with multiple parts should be
assembled
Before transporting instruments to the decontamination room, what should the surgical technologist
complete? - correct answer Presoak instruments in detergent solution
Which solution is best for presoaking instruments in the OR at the end of a procedure? - correct answer
enzyme
The strips on steam chemical indicators change to what color upon exposure to sterilization
parameters? - correct answer black
What is the first step of opening a small, Sterile wrapped package when establishing the sterile field? -
correct answer Open first flap away from self
Which of the following microorganism is used within the biological indicator for the ethylene oxide
sterilization? - correct answer Bacillus atrophaeus
To prevent peel pack pouches from opening during sterilization, the surgical technologist should: -
correct answer Force out air from pouch
Which of the following statement is incorrect one double peel packing and items for sterilization?
A. Inner peel pack is sterile
B. Heavy items should be double peel packed
C. Do not bend multiple items together.