1. _________ on the suction line of an air conditioner indicates a problem.
· Dryness
· Condensation
· Frost or ice - Answers -Condensation

2. While inspecting an air conditioner, the liquid line (smaller tube) should feel ______ to
the touch.
· cool
· warm - Answers -cool

3. Cooling capacity is typically measured in ________.
· cubic centimeters
· pounds
· ounces
· tons - Answers -tons

4. While inspecting an air conditioner, the suction line (larger tube) should feel ______
to the touch.
· warm
· cool - Answers -warm

5. Air conditioning should not be tested if the outside temperature is ___________.
· above 81° F
· between 66° and 80° F
· below 65° F
· measured in Fahrenheit - Answers -below 65° F

6. If a condensing unit is out of level or wobbles, look for __________.
· stress on the foundation
· gyroscopic differential
· stress on the refrigerant lines
· stress on the condenser slab - Answers -stress on the condenser slab

7. In many regions, an air conditioner's exterior electrical disconnect is required in sight
of the
___________.

,· electrical service entrance
· grounding rod
· electric panel
· condensing unit - Answers -condensing unit


213. A chimney top should be at least ________.
· 10 feet above the roof and 3 feet above anything within 2 feet
· 2 feet above the roof and 10 feet higher than anything within 3 feet
· 3 feet above the roof and 2 feet higher than anything within 10 feet
· 3 feet above the roof and 10 feet higher than anything within 2 feet - Answers -3 feet
above the roof and 2 feet higher than anything within 10 feet

214. What type of window does not offer easy egress?
· slider
· double-hung
· hopper
· casement - Answers -hopper

215. T/F: A home inspector is required to check all cycles of a dishwasher.
· True
· False - Answers -False

216. An air chamber is typically located in a(n) ______________.
· vent stack
· chimney flue
· supply line above a faucet or valve
· air conditioner - Answers -supply line above a faucet or valve

217. If you can inspect only part of a crawlspace because of stored items, what should
you do?
· move all the stored items first
· report that the crawlspace was inspected
· complain to the seller
· report that the crawlspace was only partially inspected due to limited access - Answers
-report that the crawlspace was only partially inspected due to limited access

218. The ________ does not have to be inspected on a fireplace.
· damper operation
· draft strength
· hearth
· firebrick - Answers -draft strength

219. Which of the following is likely to be a non-load-bearing wall?
· a wall that has a girder resting on it
· an exterior wall

,· a wall that runs perpendicular to the ceiling joists
· a wall that runs parallel to the ceiling joists - Answers -a wall that runs parallel to the
ceiling joists

8. T/F: On an air conditioner, a loose or misaligned fan belt can reduce the amount of
air flowing past the evaporator coil and decrease the system's performance.
· False
· True - Answers -True

9. When testing cold-air returns, turn the furnace or air conditioner on and hold a tissue
next to the cold air return. There should be ___________.
· no movement of the tissue, even though the blower is on
· enough suction to pull the tissue toward the return
· enough pressure to blow the tissue away - Answers -enough pressure to blow the
tissue away

10. The best location for a thermostat is ____________.
· above a heat register
· in direct sunlight
· the wall in the dining room
· near the main exterior door - Answers -near the main exterior door

11. The hot wire in a typical 120-volt circuit is _________.
· green
· white
· bare copper
· black - Answers -black

12. The neutral wire in a typical 120-volt circuit is ________.
· bare copper
· black
· white
· green - Answers -white

13. Fuses do not provide protection against __________.
· overloading
· short circuits
· lightning surges
· large ground faults - Answers -lightning surges

14. The minimum height above a driveway for an electrical service drop is __________.
· trick question; electrical service lines may not run above driveways
· 12 feet
· 14 feet
· 18 feet - Answers -12 feet

, 15. The primary purpose of an electrical service drip loop is to prevent water from
___________.
· entering the double loop
· getting into the service mast
· causing a short to the grounding rod
· entering the plumbing system - Answers -getting into the service mast

16. The following are all potential points for water intrusion into the electrical service
entrance mast, except the ________.
· roof flashing around the mast
· GFCI electrical outlet plate cover
· open service mast cap
· meter base - Answers -GFCI electrical outlet plate cover

17. The electrical panel rating should be no smaller than _________.
· 400 amps
· the main breaker
· two times the smallest breaker - Answers -the main breaker

18. How much clearance should be provided in front of an electrical service panel?
· the length of a screwdriver
· 1 foot
· 3 feet
· 6 feet - Answers -3 feet

19. In a home with central heating, a room with an air supply but no return can
experience problems from ______ if there is inadequate space beneath the door.
· moisture
· pressurization
· depressurization
· overheating - Answers -depressurization

20. Exterior electrical service wires should be at least 3 feet away from .
· both the bottom and front of all unopenable/inoperable windows
· all windows
· the bottom, sides and front of openable/operable windows
· the bottom, sides, top and front of all openable/operable windows - Answers -the
bottom, sides, top and front of all openable/operable windows

21. Electrical service entrance conduits should be secured to the exterior of the home
_________.
· using joist hangers
· every 5 to 6 feet
· with electrical tape
· every 5 to 6 inches - Answers -using joist hangers

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
mereka Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
457
Member since
2 year
Number of followers
215
Documents
9078
Last sold
1 day ago
anchor

on this page, you will find all documents, package deal

3.9

87 reviews

5
43
4
15
3
13
2
5
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions