INTERNACHI EXAM PART 2 QUESTIONS
AND ANSWERS



aAccording to the InterNACHI® Home Inspection Standards of Practice, lawn-irrigation
systems are part of a home inspection. - Correct Answers -false

The home inspection includes checking the walkways and driveways, according to the
InterNACHI® Home Inspection Standards of Practice. - Correct Answers -True

Which tool may be used during the electrical inspection? - Correct Answers -GFCI
tester

The InterNACHI inspector _________ accept any disclosed or undisclosed
commissions, rebates, profits or other benefit related to a property to be inspected. -
Correct Answers -shall not

An issue that would be considered a safety hazard that could injure someone would
also be considered a _____ defect. - Correct Answers -material

The home inspector is required to inspect the ventilation of unfinished space - Correct
Answers –true

In order to climb onto a roof, the ladder should extend _______ higher than the roof. -
Correct Answers -3 feet

One-person inspection businesses _______________ - Correct Answers -should be
especially diligent with regard to safety because no one is looking out for the inspector
but himself/herself

Anyone using a ladder shall __________. - Correct Answers -always face the ladder
when climbing up and down

Air-admittance valves are __________ to vent fixtures installed at island structures in
kitchens. - Correct Answers -permitted

Open electrical service conductors and multi-conductor cables that are not installed in a
raceway or provided with an approved overall outer jacket should have a clearance of at
least __________ feet from the sides of doors, porches, decks, stairs, ladders, fire

, escapes and balconies, and from the sides and bottoms of operable windows. - Correct
Answers -3

In a solid wood floor joist, a bored hole should be at least ___ inches from the top or
bottom edge. - Correct Answers -2

For roof slopes from 2:12 to 4:12, _______ layers of underlayment may be applied. -
Correct Answers -two

The upper edge of a masonry chimney cleanout should be at least ____ inches below
the lowest inlet opening. - Correct Answers -6

The following should be evaluated by the home inspector: _____. - Correct Answers -
none of these

Observed indications of active water penetration should be reported by the inspector as
in need of _____. - Correct Answers -correction

_____ flashing should be installed on the lowest face of a chimney - Correct Answers -
Apron

Exposed nails on metal tile roofs are _________, even if they are made of the same
material. - Correct Answers -not acceptable

__________ is not normally used for flashing. - Correct Answers -Timber

Trees overhanging the structure _______ be noted due to the potential for damage to
the roof covering. - Correct Answers -should

__________-clips are required between many sheathing panels - Correct Answers -H

The image shows _________________, and a very dangerous condition exists,
especially to the unwary home inspector. - Correct Answers -missing insulation

For a 12-gauge copper wire, the maximum overcurrent protection rating is _____ amps.
- Correct Answers -20

The inspector should defer __________ for an electrical specialist evaluation - Correct
Answers -copper-clad aluminum wiring

An electrical panel that uses a double-pole breaker to isolate multiple main disconnects
(breakers) from the 120-volt circuits is called a _____ panel. - Correct Answers -Split-
bus

The service-entrance conductors (blue arrow) are the service conductors located
between the terminals of the service equipment (main disconnect) and a point usually

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
mereka Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
457
Member since
2 year
Number of followers
215
Documents
9078
Last sold
1 day ago
anchor

on this page, you will find all documents, package deal

3.9

87 reviews

5
43
4
15
3
13
2
5
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions