The power module is equipped with a ______ which activates when low pressure alarm occurs
✔✔ RIT light
MSA G1 SCBA ✔✔ pressure-demand self-contained breathing apparatus that operates
independent of the ambient air
The RIT light on the power module makes it easier to locate the ______? ✔✔ UAC
UAC ✔✔ Universal Air Connection
The power module contains an ______? ✔✔ internal real time clock
The G1 Harness and Carrier Assembly consists of how many parts? ✔✔ 8
The ______ provide weight distribution across the shoulder ✔✔ shoulder straps/pads
The regulator and speaker module are typically placed on the ______ side ✔✔ left
The control module is placed on the ______ side ✔✔ right
The G1 Speaker Module ______ ✔✔ amplifies and clarifies the speech from the face piece
during use
How do you turn off the speaker module? ✔✔ press the button on the top
, The ExtendAire II also known as the buddy breather is located on what side? ✔✔ left
The buddy breather manifold contains both a ______ ✔✔ male and female Quick Connect for
ease of connection
The buddy breather is attached to ______ ft of useable hose and when paired to another buddy
breather make up ______ ft of useable hose ✔✔ 3 ft, 6 ft
Visually inspect the SCBA ______ (3) ✔✔ upon receipt
daily
after each use
What way do you turn the bypass valve (knob) to open the bypass? ✔✔ counter clockwise
Carbon-wrapped cylinders must be tested every ______ years ✔✔ 5
If the SCBA has passed the visual inspection successfully, conduct the ______ ✔✔ functional
tests daily and after each use
When filling a cylinder, fill the cylinder to ______ PSI to ensure you achieve the maximum
amount of useable air ✔✔ 4950 PSI
The low pressure alarms should continue until air pressure is ______ ✔✔ 200 PSI or less
How many buddy lights does the G1 SCBA contain? ✔✔ 5 (