and CORRECT Answers
nfpa 1901 covers - CORRECT ANSWER - fire apparatus
nfpa 1901 says vehicles must put out what gal - CORRECT ANSWER - 1500 to 3000 gal
how many external mdh fill connections are needed - CORRECT ANSWER -1
mws equipped with - CORRECT ANSWER - 1000 gal
valve strainer and 30 degree elbow
slow closing 3 in or greater valves
requirements for large tank discharge - CORRECT ANSWER - discharge 90% of tank
volume at 1,000 gpm
if a mws apparatus is considered a tanker it meets what gpm and percentage output - CORRECT
ANSWER✅✅- 500 gpm until 80% is used
PDP= required intake pressure+TPL - CORRECT ANSWER✅✅-
TPL= - CORRECT ANSWER - FL+EP+APL
FL= - CORRECT ANSWER - C*Qsqured*L
daily checkout is divided into how many sections - CORRECT ANSWER -8
left front - CORRECT ANSWER - cab doors
, saddle tanks
springs and shackles
platforms and rails
wheel and tire
tools for engine test - CORRECT ANSWER - air filer trestriction guage
oil
coolant
drive belt tension - CORRECT ANSWER - 1/2-3/4 in
coolant reservoir how full - CORRECT ANSWER - half full
weekly check items - CORRECT ANSWER - pump intake strainers
pump gearbox and packing glands
rapid dump system
daily inspection items - CORRECT ANSWER - pump primer
pump pressure control device
pump drive control
winterization cooling system
fuel tank
relief valves
pump
2 types of test on truck - CORRECT ANSWER - pre service and fire pump service test